ONOskar Neumann

Oskar Neumann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oskar Neumann has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Silvia Budday

    Institute of Continuum Mechanics and Biomechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstraße 5, Erlangen, 91058, Germany

    5 shared publications
  • Paul Steinmann

    Institute of Applied Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstraße 5, Erlangen, 91058, Germany

    4 shared publications
  • Harsh Vardhan Surana

    Institute of Continuum Mechanics and Biomechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstraße 5, Erlangen, 91058, Germany

    3 shared publications
  • Rahul Gopalan Ramachandran

    Institute of Applied Mechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstraße 5, Erlangen, 91058, Germany

    3 shared publications
  • Daniel Wehner

    Max Planck Institute for the Science of Light, Erlangen, Germany

    1 shared publication
  • Daniel Wehner

    Max-Planck-Zentrum für Physik und Medizin, Kussmaulallee 2, Erlangen, 91054, Germany; Max Planck Institute for the Science of Light, Staudtstraße 2, Erlangen, 91058, Germany; Institute of Zoology, University of Cologne, Zülpicher Straße 47b, Cologne, 50674, Germany

    1 shared publication

Latest Publications

  • Open Access

    In silico model of axonal pathfinding during spinal cord regeneration in zebrafish larvae

    by Oskar Neumann, Mathar Kravikass, Nora John, Rahul Gopalan Ramachandran, Paul Steinmann, Vasily Zaburdaev, Daniel Wehner, Silvia Budday

  • Open Access

    Multimodal mechanical characterization pipeline for spinal cord tissue

    by Oskar Neumann, Rahul Gopalan Ramachandran, Harsh Vardhan Surana, Friedrich Paulsen, Michael Scholz, Simone Gaffling, Paul Steinmann, Silvia Budday


  • Open Access

    Spatial scale of indentation explains shift in ratio between spinal cord gray and white matter stiffness

    by Oskar Neumann, Harsh Vardhan Surana, Maik Hintze, Stefanie Kuerten, Thomas Franz, Rahul Gopalan Ramachandran, Paul Steinmann, Silvia Budday

    The structural integrity of spinal cord tissue and the transmission of mechanical stimuli across the different levels of tissue microarchitecture and varying spatial scales of mechanical loading challenge experimental and computational efforts to accurately model, simulate and interpret tissue mechanics, leading to conflicting findings in existing literature. Here, we demonstrate that the bead size used in spherical indentation tests significantly affects the stiffness ratio of spinal cord gray to white matter, a dependence which we only observe on the transverse plane and not the coronal plane of the tissue. Our study reveals a shift in stiffness ratio such that for smaller spherical indenters gray matter is stiffer than white matter, while for larger indenters, white matter is stiffer than gray matter. The mean relative change from the 100 µ m bead to the 500 µ m bead differed between anatomical planes, with transverse sections showing a decrease in gray matter (−13.3%) and an increase in white matter stiffness (+26.9%), accompanied by a reduction in the gray-to-white matter stiffness ratio from 1.07 to 0.76, whereas coronal sections exhibited increases in both gray (+21.0%) and white matter (+33.8%), along with a change in the ratio from 0.99 to 1.14. These findings contribute to explaining previously contradictory results in the literature and underscore the relevance of spatial scales in mechanical characterization studies.

  • Open Access

    In silico model of axonal pathfinding during spinal cord regeneration in zebrafish larvae

    by Oskar Fabian Neumann, Mathar Kravikass, Nora John, Rahul Gopalan Ramachandran, Paul Steinmann, Vasily Zaburdaev, Daniel Wehner, Silvia Budday

    Functional spinal cord repair in zebrafish is governed by regeneration-favorable biochemical and mechanical cues within the lesion microenvironment. Alterations in extracellular matrix composition and stiffness are closely associated with axon regeneration. However, experimentally dissecting the interplay between mechanical signals and axonal regrowth in vivo remains technically challenging. Here, we present an agent-based modeling framework to simulate stiffness-mediated axonal growth trajectories across the lesion. We use this model to explore potential mechanisms underlying the characteristic growth patterns observed during zebrafish spinal cord regeneration. Computational predictions were qualitatively compared with confocal imaging data obtained from larval zebrafish. These phenomenological comparisons revealed a close agreement between simulated and experimentally observed axon growth, indicating that experimentally observed patterns could be governed by transient changes in the stiffness profile of the spinal cord and lesion microenvironment. Hence, our computational framework provides an in silico platform for investigating the role of mechanical cues in axon regeneration in the injured spinal cord.

  • Open Access

    Mechanical characteristics of spinal cord tissue by indentation

    by Oskar Neumann, Harsh Vardhan Surana, Stephen Melly, Paul Steinmann, Silvia Budday