Alexander P. Borisov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander P. Borisov has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Andrey N. Nikolaenko
Samara State Medical University
10 shared publications - Gennadiy P. Kotelnikov
Samara State Medical University
7 shared publications - Viktor V. Ivanov
Samara State Medical University
4 shared publications - Denis V. Lyukshin
Samara State Medical University
2 shared publications - Dmitrii A. Dolgushkin
Samara State Medical University
2 shared publications - Larisa Teodorovna Volova
Samara State Medical University
2 shared publications
Latest Publications
- Open Access
- 19 November 2026
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
Our experience in developing an all-ceramic first carpal-metacarpal joint endoprosthesis
Introduction. Risarthrosis is one of the common causes of disability in patients. Traditional interventions - trapezectomy and arthrodesis - have a number of serious complications. Therefore, the development of alternative surgical methods is relevant, including the arthroplasty of the first carpal-metacarpal joint (CMC-1). The aim of the work was to develop and experimentally substantiate an individual two-component unrelated whole-ceramic endoprosthesis of the CMC-1 for the surgical treatment of risarthrosis. Methods. For this study, cadaveric material was used: 5 male and 7 female hands, a total of 12 operations were performed. At the Research Institute of Bionics and Personalized Medicine, SamSMU designed and developed a two-component all-ceramic CMC-1 endoprosthesis, as well as special tools for installing implant components. Results. Based on computed tomography data, the design of an individual endoprosthesis was simulated. Further, computer modeling was carried out to create an individual virtual model of the implant. The distal and proximal components of the zirconium ceramic implant were manufactured by machining on numerically controlled machines. The proximal component was positioned on the articular surface of the trapezius bone, the distal component was mounted with an impactor and soft hammering. After installing the components of the endoprosthesis, load tests were CMC-1 performed, while the failure of the implant design due to its proximal component was revealed. Discussion. Currently, none of the surgical treatments for risarthrosis have clear benefits. To continue research for the development of an endoprosthesis, it is necessary to rethink the geometry of the implant leg, introduce additional anchor fixation, test various coatings to increase the coefficient of friction and osteointegration. Conclusion. An individual two-component unbound whole-ceramic design of the CMC-1 endoprosthesis for the surgical treatment of risarthrosis was experimentally substantiated. Despite the successful completion of the design and manufacturing stages, the design turned out to be mechanically untenable due to the ineffective fixation of the proximal component. significant experience was gained in the course of work, which can be used to develop new design options.
- 19 November 2026
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
Open AccessOur experience in developing an all-ceramic first carpal-metacarpal joint endoprosthesis
Introduction. Risarthrosis is one of the common causes of disability in patients. Traditional interventions - trapezectomy and arthrodesis - have a number of serious complications. Therefore, the development of alternative surgical methods is relevant, including the arthroplasty of the first carpal-metacarpal joint (CMC-1). The aim of the work was to develop and experimentally substantiate an individual two-component unrelated whole-ceramic endoprosthesis of the CMC-1 for the surgical treatment of risarthrosis. Methods. For this study, cadaveric material was used: 5 male and 7 female hands, a total of 12 operations were performed. At the Research Institute of Bionics and Personalized Medicine, SamSMU designed and developed a two-component all-ceramic CMC-1 endoprosthesis, as well as special tools for installing implant components. Results. Based on computed tomography data, the design of an individual endoprosthesis was simulated. Further, computer modeling was carried out to create an individual virtual model of the implant. The distal and proximal components of the zirconium ceramic implant were manufactured by machining on numerically controlled machines. The proximal component was positioned on the articular surface of the trapezius bone, the distal component was mounted with an impactor and soft hammering. After installing the components of the endoprosthesis, load tests were CMC-1 performed, while the failure of the implant design due to its proximal component was revealed. Discussion. Currently, none of the surgical treatments for risarthrosis have clear benefits. To continue research for the development of an endoprosthesis, it is necessary to rethink the geometry of the implant leg, introduce additional anchor fixation, test various coatings to increase the coefficient of friction and osteointegration. Conclusion. An individual two-component unbound whole-ceramic design of the CMC-1 endoprosthesis for the surgical treatment of risarthrosis was experimentally substantiated. Despite the successful completion of the design and manufacturing stages, the design turned out to be mechanically untenable due to the ineffective fixation of the proximal component. significant experience was gained in the course of work, which can be used to develop new design options.
- Open Access
- 21 May 2026
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 26 (2) , 34-42
Analysis of the incidence, prevalence of hip joint pathology in the Samara region and outcomes of endoprosthetics according to a multidisciplinary hospital based on evidence-based medicine indicators
Aim: to analyze the incidence and prevalence of complex hip joint pathology in the Samara region for the period 2015–2024 and the outcomes of endoprosthetics at the V.D. Seredavin Joint Surgery Center in the period 2006–2025. from the standpoint of evidence-based medicine. Material and methods. 9472 patients with hip joint pathology who underwent primary hospital surgery and 721 (7.6%) who underwent revision were studied. The statistical analysis was carried out using standard statistical processing methods by using the Data Analysis add-on in Microsoft Office Excel 2021. Results. The prevalence of dysplastic coxarthrosis (CA) at the end of 2024 in Samara was 43.95 per 100,000 population. Among the patients who required re-hospitalization (n=721), 53.7% were diagnosed with dysplastic CA. After hip joint replacement, complications were detected in 5/1% (35 cases), including 9 dislocations (1.2%) and 5 deaths (0.7%). Our approach in endoprosthetics allows us to achieve better results compared to the control group: reduce the risk of death by 23.7% and reduce the chances of death by 2.2 times. Conclusion. Our research has proved the need to form a unified register of patients with hip joint pathology and with surgical interventions at the level of the Ministry of Health of the Samara Region, which will make it possible to update the lists of patients in need of endoprosthetics and improve the system of organization of high-tech treatment methods.
- 21 May 2026
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 26 (2) , 34-42
Open AccessAnalysis of the incidence, prevalence of hip joint pathology in the Samara region and outcomes of endoprosthetics according to a multidisciplinary hospital based on evidence-based medicine indicators
Aim: to analyze the incidence and prevalence of complex hip joint pathology in the Samara region for the period 2015–2024 and the outcomes of endoprosthetics at the V.D. Seredavin Joint Surgery Center in the period 2006–2025. from the standpoint of evidence-based medicine. Material and methods. 9472 patients with hip joint pathology who underwent primary hospital surgery and 721 (7.6%) who underwent revision were studied. The statistical analysis was carried out using standard statistical processing methods by using the Data Analysis add-on in Microsoft Office Excel 2021. Results. The prevalence of dysplastic coxarthrosis (CA) at the end of 2024 in Samara was 43.95 per 100,000 population. Among the patients who required re-hospitalization (n=721), 53.7% were diagnosed with dysplastic CA. After hip joint replacement, complications were detected in 5/1% (35 cases), including 9 dislocations (1.2%) and 5 deaths (0.7%). Our approach in endoprosthetics allows us to achieve better results compared to the control group: reduce the risk of death by 23.7% and reduce the chances of death by 2.2 times. Conclusion. Our research has proved the need to form a unified register of patients with hip joint pathology and with surgical interventions at the level of the Ministry of Health of the Samara Region, which will make it possible to update the lists of patients in need of endoprosthetics and improve the system of organization of high-tech treatment methods.
- 31 March 2026
- Published by LLC Science and Innovations in Saratov Journal of Medical Scientific Research
- Vol. 22 (1)
Research of experimental samples of implants with different types of coatings in an experiment in vivo
Objective: Evaluation of safety and osteointegrative properties of experimental samples of implants with different types of coatings in the experiment in vivo in rats. Material and methods. Morphological study is performed on 60 laboratory sexually mature rats. The materials of the study were samples of 4 groups of groups with various types of coatings based on titanium BT6. Results. The biological compatibility of all samples of implants has been proved. In the group of implants without covering, there was no pronounced bone formation, the stability of the implant remained low by 2 months (2.9±1.1 points on the implant stability scale). Hitosan coating implants showed low stability indicators (1.8±0.1 points by week 2), however, pronounced stimulation of osseogenesis was observed. In a group with antibacterial coating, good integration and small mobility of the implant was noted (3.4±0.3 points by 1 month), apnibacterial coating was preserved for 2 weeks. Conclusions. Hydroxyapatite and chitosan coatings contributed to the acceleration of osteointegration, by stimulating angiogenesis, synthesis of stroma collagen and bone formation, with a full degree of biocompatibility and rapid biodegradation. The antibacterial coating ensured the rapid relief of inflammatory phenomena in the field of postoperative wound.
- 31 March 2026
- Published by LLC Science and Innovations in Saratov Journal of Medical Scientific Research
- Vol. 22 (1)
Research of experimental samples of implants with different types of coatings in an experiment in vivo
Objective: Evaluation of safety and osteointegrative properties of experimental samples of implants with different types of coatings in the experiment in vivo in rats. Material and methods. Morphological study is performed on 60 laboratory sexually mature rats. The materials of the study were samples of 4 groups of groups with various types of coatings based on titanium BT6. Results. The biological compatibility of all samples of implants has been proved. In the group of implants without covering, there was no pronounced bone formation, the stability of the implant remained low by 2 months (2.9±1.1 points on the implant stability scale). Hitosan coating implants showed low stability indicators (1.8±0.1 points by week 2), however, pronounced stimulation of osseogenesis was observed. In a group with antibacterial coating, good integration and small mobility of the implant was noted (3.4±0.3 points by 1 month), apnibacterial coating was preserved for 2 weeks. Conclusions. Hydroxyapatite and chitosan coatings contributed to the acceleration of osteointegration, by stimulating angiogenesis, synthesis of stroma collagen and bone formation, with a full degree of biocompatibility and rapid biodegradation. The antibacterial coating ensured the rapid relief of inflammatory phenomena in the field of postoperative wound.
- 31 March 2026
- Published by LLC Science and Innovations in Saratov Medical Journal
- Vol. 7 (1)
Studying implants with different coating types in an in vivo experiment
Objective: to evaluate the safety and osseointegration properties of experimental implant specimens with different types of coatings in an in vivo experiment in rats. Materials and Methods. A morphological study was performed on 60 laboratory sexually mature rats. The study materials were implant specimens from four groups with different types of VT6 titanium alloy coatings. Results. Biological compatibility of all implant specimens was confirmed. In the uncoated implant group, no significant bone formation was observed, and implant stability remained low by Month 2 (2.9±1.1 pts on the implant stability scale). Chitosan-coated implants exhibited low stability (1.8±0.1 pts by Week 2), but significant stimulation of osteogenesis was observed. In the antibacterial coating group, good integration and minimal implant mobility were noted (3.4±0.3 pts after one), and the antibacterial coating was preserved for two weeks. Conclusion: Hydroxyapatite and chitosan coatings contributed to quicker osseointegration via stimulating angiogenesis, stromal collagen synthesis, and bone formation, while maintaining full biocompatibility and rapid biodegradation. The antibacterial coating ensured rapid relief of inflammation in the postoperative wound area.
- 31 March 2026
- Published by LLC Science and Innovations in Saratov Medical Journal
- Vol. 7 (1)
Studying implants with different coating types in an in vivo experiment
Objective: to evaluate the safety and osseointegration properties of experimental implant specimens with different types of coatings in an in vivo experiment in rats. Materials and Methods. A morphological study was performed on 60 laboratory sexually mature rats. The study materials were implant specimens from four groups with different types of VT6 titanium alloy coatings. Results. Biological compatibility of all implant specimens was confirmed. In the uncoated implant group, no significant bone formation was observed, and implant stability remained low by Month 2 (2.9±1.1 pts on the implant stability scale). Chitosan-coated implants exhibited low stability (1.8±0.1 pts by Week 2), but significant stimulation of osteogenesis was observed. In the antibacterial coating group, good integration and minimal implant mobility were noted (3.4±0.3 pts after one), and the antibacterial coating was preserved for two weeks. Conclusion: Hydroxyapatite and chitosan coatings contributed to quicker osseointegration via stimulating angiogenesis, stromal collagen synthesis, and bone formation, while maintaining full biocompatibility and rapid biodegradation. The antibacterial coating ensured rapid relief of inflammation in the postoperative wound area.
- 19 December 2025
- Published by Russian Ilizarov Scientific Centre Restorative Traumatology and Orthopaedics in Genij Ortopedii
- Vol. 31 (6)
Algorithm for postoperative management of patients after ankle replacement surgery
Introduction Total ankle arthroplasty (TAA) can be associated with postoperative difficulties during the rehabilitation phase. A unified, tailored approach to rehabilitation and postoperative care is essential for the patients.The objective was to evaluate clinical effectiveness of the algorithm developed for postoperative management of TAA patients to improve functional recovery, reduce postoperative complications for greater patient satisfaction. Material and methods The study included 28 patients with impaired distal tibia and the ankle. The surgical treatment performed after a comprehensive examination included segmental resection of the distal tibia and ankle replacement of the original design. The implant had an articulating ankle joint and the distal tibia replacement. The algorithm developed for postoperative rehabilitation relied on a six-level approach borrowed from rehabilitation guidelines for total ankle arthroplasty devised at the Massachusetts General Hospital. Results Postoperative management included multimodal analgesia with a regional component, multi‑level prophylaxis of infection, antithrombotic protection and staged immobilization with early controlled loading. Primary wound healing was observed in all patients. The mean postoperative swelling measured with the visual swelling scale decreased from (3.8 ± 0.6) to (0.9 ± 0.4) scores after six weeks. Dorsiflexion measured (20 ± 3)°, plantar flexion was (36 ± 4)°, and 100 % of patients could regain a stable biphasic gait pattern at 16 weeks. Discussion There are few detailed protocols for postoperative care and rehabilitation of TAA patients. The algorithm offered showed the effectiveness with the gait being almost normal with the range of motion and strength restored at four months. Patients reported high satisfaction measured with functional scales and subjective quality of life assessment. Conclusion The step-by-step six-phase algorithm developed for postoperative management and rehabilitation of patients treated with segmental tibia resection and TAA facilitated a lower risk of postoperative complications, reduced function recovery time and high satisfaction ratings.
- 19 December 2025
- Published by Russian Ilizarov Scientific Centre Restorative Traumatology and Orthopaedics in Genij Ortopedii
- Vol. 31 (6)
Algorithm for postoperative management of patients after ankle replacement surgery
Introduction Total ankle arthroplasty (TAA) can be associated with postoperative difficulties during the rehabilitation phase. A unified, tailored approach to rehabilitation and postoperative care is essential for the patients.The objective was to evaluate clinical effectiveness of the algorithm developed for postoperative management of TAA patients to improve functional recovery, reduce postoperative complications for greater patient satisfaction. Material and methods The study included 28 patients with impaired distal tibia and the ankle. The surgical treatment performed after a comprehensive examination included segmental resection of the distal tibia and ankle replacement of the original design. The implant had an articulating ankle joint and the distal tibia replacement. The algorithm developed for postoperative rehabilitation relied on a six-level approach borrowed from rehabilitation guidelines for total ankle arthroplasty devised at the Massachusetts General Hospital. Results Postoperative management included multimodal analgesia with a regional component, multi‑level prophylaxis of infection, antithrombotic protection and staged immobilization with early controlled loading. Primary wound healing was observed in all patients. The mean postoperative swelling measured with the visual swelling scale decreased from (3.8 ± 0.6) to (0.9 ± 0.4) scores after six weeks. Dorsiflexion measured (20 ± 3)°, plantar flexion was (36 ± 4)°, and 100 % of patients could regain a stable biphasic gait pattern at 16 weeks. Discussion There are few detailed protocols for postoperative care and rehabilitation of TAA patients. The algorithm offered showed the effectiveness with the gait being almost normal with the range of motion and strength restored at four months. Patients reported high satisfaction measured with functional scales and subjective quality of life assessment. Conclusion The step-by-step six-phase algorithm developed for postoperative management and rehabilitation of patients treated with segmental tibia resection and TAA facilitated a lower risk of postoperative complications, reduced function recovery time and high satisfaction ratings.
- Open Access
- 18 July 2025
- Published by FSPSI SCFHHRP in Acta Biomedica Scientifica
- Vol. 10 (3) , 183-190
The use of the endoprosthesis of the first plusnephalanx joint of the original design (clinical case)
Background. Currently, the replacement surgery of the first metatarsophalangeal joint (MTP joint) is considered to be one of the effective, invasive method for treating severe forms of osteoarthritis of the MTP joint. However, there are a number of postoperative complications that may be caused by the prosthesis itself. Research in this area can provide valuable information that will assist specialists in making decisions regarding the most suitable implant for each patient. Additionally, improvements in the design of implants for MTP joint replacement and further studies will help make them more effective, durable, and biocompatible. The aim. To present a clinical case of osteoarthritis of the first metatarsophalangeal joint (Hallux rigidus) treated surgically by conducting total joint replacement with a monolithic ceramic implant featuring an optimal stem design. Materials and methods. A clinical case is a 47-year-old patient presenting with deforming osteoarthritis of the 1st MTP joint. It was managed by arthroplasty of 1st MTP joint using an all-ceramic endoprosthesis with an optimal leg (RU № 226697). Results. Three months after the operation, the pronounced significant increase in the range of movement and pain reduction in the 1st MTP joint were observed. Positive dynamics was preserved 6 and 12 months postoperatively. Conclusion. The results of the surgery indicate that the replacement of the first metatarsophalangeal joint replacement using a monolithic ceramic implant with an optimal stem design is efficient surgical intervention. This approach significantly not only alleviates pain, but improves the quality of life for patients overall. However, to fully assess the long-term results and sustainability of the achieved effects, further studies are needed to analyze the distant outcomes of this intervention.
- 18 July 2025
- Published by FSPSI SCFHHRP in Acta Biomedica Scientifica
- Vol. 10 (3) , 183-190
Open AccessThe use of the endoprosthesis of the first plusnephalanx joint of the original design (clinical case)
Background. Currently, the replacement surgery of the first metatarsophalangeal joint (MTP joint) is considered to be one of the effective, invasive method for treating severe forms of osteoarthritis of the MTP joint. However, there are a number of postoperative complications that may be caused by the prosthesis itself. Research in this area can provide valuable information that will assist specialists in making decisions regarding the most suitable implant for each patient. Additionally, improvements in the design of implants for MTP joint replacement and further studies will help make them more effective, durable, and biocompatible. The aim. To present a clinical case of osteoarthritis of the first metatarsophalangeal joint (Hallux rigidus) treated surgically by conducting total joint replacement with a monolithic ceramic implant featuring an optimal stem design. Materials and methods. A clinical case is a 47-year-old patient presenting with deforming osteoarthritis of the 1st MTP joint. It was managed by arthroplasty of 1st MTP joint using an all-ceramic endoprosthesis with an optimal leg (RU № 226697). Results. Three months after the operation, the pronounced significant increase in the range of movement and pain reduction in the 1st MTP joint were observed. Positive dynamics was preserved 6 and 12 months postoperatively. Conclusion. The results of the surgery indicate that the replacement of the first metatarsophalangeal joint replacement using a monolithic ceramic implant with an optimal stem design is efficient surgical intervention. This approach significantly not only alleviates pain, but improves the quality of life for patients overall. However, to fully assess the long-term results and sustainability of the achieved effects, further studies are needed to analyze the distant outcomes of this intervention.
- Open Access
- 11 June 2025
- Published by ECO-Vector LLC in Traumatology and Orthopedics of Russia
- Vol. 31 (2) , 178-189
Complications of Osseointegrated Prostheses and Comparison of Quality of Life in Patients with Different Prosthetic Systems: A Review
Background. Despite recent advances in medicine, the amputation rate remains quite high. Among civilians, vascular diseases (82%) and injuries (17%) are the main causes leading to disability. Half of the patients who have undergone amputation have difficulty using a traditional prosthetic socket (PS). An alternative to PS are osseointegrated (OI) prostheses that transmit loads through the bones, provide increased comfort and the possibility of fitting faulty and short stumps. The aim — based on a literature review, to determine the mechanical and infectious complications rate of osseointegrated prosthetic systems and compare the quality of life in patients with osseointegrated prostheses and prosthetic in sockets. Methods. The search for scientific publications was performed in Scopus, PubMed, ResearchGate, Google Scholar, and eLIBRARY databases using the keywords related to osseointegration and quality of life, from 2000 to 2024. Results. Infections in the stoma area may develop in 11-67% of patients, with 5-8% of cases requiring surgical intervention. Use of ОI prostheses significantly improved functional indicators: the proportion of patients with a K-level ≥3 increased from 5 to 100%, and the results of the six-minute walk test increased from 292 to 448 meters. All indicators of quality of life according to the SF-36 scale improved, and the proportion of patients using the prosthesis for more than 13 hours a day increased from 43 to 95%. Osseointegrated prosthetics is superior to traditional methods in all Q-TFA indicators. Conclusions. Osseointegrated implants improve patient’s perception of the prosthesis and feel like a part of the body rather than a prosthetic device compared to dentures with stump sleeves. Osseointegrated prosthetics is a promising technology, but requires further research and improvement of the soft tissue interface for wider application.
- 11 June 2025
- Published by ECO-Vector LLC in Traumatology and Orthopedics of Russia
- Vol. 31 (2) , 178-189
Open AccessComplications of Osseointegrated Prostheses and Comparison of Quality of Life in Patients with Different Prosthetic Systems: A Review
Background. Despite recent advances in medicine, the amputation rate remains quite high. Among civilians, vascular diseases (82%) and injuries (17%) are the main causes leading to disability. Half of the patients who have undergone amputation have difficulty using a traditional prosthetic socket (PS). An alternative to PS are osseointegrated (OI) prostheses that transmit loads through the bones, provide increased comfort and the possibility of fitting faulty and short stumps. The aim — based on a literature review, to determine the mechanical and infectious complications rate of osseointegrated prosthetic systems and compare the quality of life in patients with osseointegrated prostheses and prosthetic in sockets. Methods. The search for scientific publications was performed in Scopus, PubMed, ResearchGate, Google Scholar, and eLIBRARY databases using the keywords related to osseointegration and quality of life, from 2000 to 2024. Results. Infections in the stoma area may develop in 11-67% of patients, with 5-8% of cases requiring surgical intervention. Use of ОI prostheses significantly improved functional indicators: the proportion of patients with a K-level ≥3 increased from 5 to 100%, and the results of the six-minute walk test increased from 292 to 448 meters. All indicators of quality of life according to the SF-36 scale improved, and the proportion of patients using the prosthesis for more than 13 hours a day increased from 43 to 95%. Osseointegrated prosthetics is superior to traditional methods in all Q-TFA indicators. Conclusions. Osseointegrated implants improve patient’s perception of the prosthesis and feel like a part of the body rather than a prosthetic device compared to dentures with stump sleeves. Osseointegrated prosthetics is a promising technology, but requires further research and improvement of the soft tissue interface for wider application.
- 29 April 2025
- Published by Media Sphere Publishing Group in Pirogov Russian Journal of Surgery
- No. 5,p. 72-78
Testing of friction node simulators for hip prostheses
Objective. To estimate advisability of prototypes of ultra-high molecular weight polyethylene (UHMWPE) in hip arthroplasty. Material and methods. We used 34 UHMWPE specimens for tests and developed a test program consisting of incoming control of specimen geometrical parameters, tribotechnical tests, assessment of liner surface condition and deviation from roundness. Results. Input control of geometrical parameters of specimens showed their heterogeneity. UHMWPE specimens with negative value (Dc—Dh) failed tribotechnical tests. Specimens with value (Dc—Dh) within 0.6—0.8 mm demonstrated lower value of T moment compared to other specimens. Conclusion. About 75% of UHMWPE prototype liners are suitable for arthroplasty.
- 29 April 2025
- Published by Media Sphere Publishing Group in Pirogov Russian Journal of Surgery
- No. 5,p. 72-78
Testing of friction node simulators for hip prostheses
Objective. To estimate advisability of prototypes of ultra-high molecular weight polyethylene (UHMWPE) in hip arthroplasty. Material and methods. We used 34 UHMWPE specimens for tests and developed a test program consisting of incoming control of specimen geometrical parameters, tribotechnical tests, assessment of liner surface condition and deviation from roundness. Results. Input control of geometrical parameters of specimens showed their heterogeneity. UHMWPE specimens with negative value (Dc—Dh) failed tribotechnical tests. Specimens with value (Dc—Dh) within 0.6—0.8 mm demonstrated lower value of T moment compared to other specimens. Conclusion. About 75% of UHMWPE prototype liners are suitable for arthroplasty.
- Open Access
- 19 December 2024
- Published by Russian Ilizarov Scientific Centre Restorative Traumatology and Orthopaedics in Genij Ortopedii
- Vol. 30 (6) , 906-915
Stenosing tenosynovitis
Introduction Stenosing tenosynovitis or trigger finger is a common cause of hand disability. With the 174year history of the condition, treatment strategy and new minimally invasive surgical approaches are essential for researchers around the world.The objective was to determine the current treatment options of the stenosing tenosynovitis using the Russian and foreign literature.Material and methods The original literature search was conducted on key resources including Scientific Electronic Library (www.elibrary.ru), the National Library of Medicine (www.pubmed.org) and MedLine. Seventy contributions were identified published for the last 10 years.Results and discussion Treatment of stenosing ligamentitis can be initiated depending on the stage of the disease, the duration, relapses or complications, comorbidities. Conservative orthopaedic treatment includes joint immobilization and/or corticosteroid injections. Although percutaneous dissection of the annular ligament is minimally invasive and has advantages of less tissue trauma, shorter recovery time, absence of painful scars open ligamentotomy can help to minimize complications and relapses of the disease.Conclusion Conservative treatment of trigger finger is effective in 47 to 93 % and surgical procedures are practical in 94–99 %. Surgical treatment can be employed with failure of conservative treatment and has been shown to be effective and with a low rate of complications and relapses.
- 19 December 2024
- Published by Russian Ilizarov Scientific Centre Restorative Traumatology and Orthopaedics in Genij Ortopedii
- Vol. 30 (6) , 906-915
Open AccessStenosing tenosynovitis
Introduction Stenosing tenosynovitis or trigger finger is a common cause of hand disability. With the 174year history of the condition, treatment strategy and new minimally invasive surgical approaches are essential for researchers around the world.The objective was to determine the current treatment options of the stenosing tenosynovitis using the Russian and foreign literature.Material and methods The original literature search was conducted on key resources including Scientific Electronic Library (www.elibrary.ru), the National Library of Medicine (www.pubmed.org) and MedLine. Seventy contributions were identified published for the last 10 years.Results and discussion Treatment of stenosing ligamentitis can be initiated depending on the stage of the disease, the duration, relapses or complications, comorbidities. Conservative orthopaedic treatment includes joint immobilization and/or corticosteroid injections. Although percutaneous dissection of the annular ligament is minimally invasive and has advantages of less tissue trauma, shorter recovery time, absence of painful scars open ligamentotomy can help to minimize complications and relapses of the disease.Conclusion Conservative treatment of trigger finger is effective in 47 to 93 % and surgical procedures are practical in 94–99 %. Surgical treatment can be employed with failure of conservative treatment and has been shown to be effective and with a low rate of complications and relapses.
- Open Access
- 15 December 2024
- Published by ECO-Vector LLC in Journal of Clinical Practice
- Vol. 15 (4) , 89-96
The effects of dental implant macrodesign on the success of prosthetic replacement
Currently dental implantation is widely used in the areas of denture defects during the orthopedic rehabilitation of the patients. The clinical success of the implantation-related prosthetic replacement depends on multiple factors, including the macrodesign of the implant (the specific features of its structure: the shape, the characteristics and the number of thread turns). However, there are not so many comparative clinical trials exploring the effects of the main characteristics of the implant on the success of prosthetic procedures. For the practical dentist, the problem of selecting the implant system remains topical, which is why the proposed review is focused on the effects of the dental implant macrodesign on the success of implantation. The search of publications was arranged in the PubMed and eLibrary search engines using the “dental implant”, “dental implant macro-design”, “number of dental implant turns” and “implant thread characteristics” search enquiries with focusing on the research works evaluating the effects of the main characteristics of the implant in terms of primary stability and osteointegration. Various geometric parameters of the implant were analyzed, such as the shape, the length, the diameter and the thread characteristics, with further evaluating their significance for optimal tension distribution, as well as the effects on bone remodeling during the process of osteointegration. The successful implantation is being achieved by synergetic combination of numerous factors. The majority of investigators adhere to the opinion that implants shall be selected individually for each specific case with taking into consideration the local and general factors. However, the characteristics of the implant thread and the number of its thread turns improve the primary stability and represent a prerequisite for successful osteointegration. The choice of implant thread construction plays an important role for a treatment result. It was shown that the macrodesign of the implant, specifically its shape (cone), its length and diameter, higher thread width and depth, lesser thread pitch and higher numbers of thread turns influence the primary stability. Specifically these characteristics, according to our opinion, assure the success of dental implantation.
- 15 December 2024
- Published by ECO-Vector LLC in Journal of Clinical Practice
- Vol. 15 (4) , 89-96
Open AccessThe effects of dental implant macrodesign on the success of prosthetic replacement
Currently dental implantation is widely used in the areas of denture defects during the orthopedic rehabilitation of the patients. The clinical success of the implantation-related prosthetic replacement depends on multiple factors, including the macrodesign of the implant (the specific features of its structure: the shape, the characteristics and the number of thread turns). However, there are not so many comparative clinical trials exploring the effects of the main characteristics of the implant on the success of prosthetic procedures. For the practical dentist, the problem of selecting the implant system remains topical, which is why the proposed review is focused on the effects of the dental implant macrodesign on the success of implantation. The search of publications was arranged in the PubMed and eLibrary search engines using the “dental implant”, “dental implant macro-design”, “number of dental implant turns” and “implant thread characteristics” search enquiries with focusing on the research works evaluating the effects of the main characteristics of the implant in terms of primary stability and osteointegration. Various geometric parameters of the implant were analyzed, such as the shape, the length, the diameter and the thread characteristics, with further evaluating their significance for optimal tension distribution, as well as the effects on bone remodeling during the process of osteointegration. The successful implantation is being achieved by synergetic combination of numerous factors. The majority of investigators adhere to the opinion that implants shall be selected individually for each specific case with taking into consideration the local and general factors. However, the characteristics of the implant thread and the number of its thread turns improve the primary stability and represent a prerequisite for successful osteointegration. The choice of implant thread construction plays an important role for a treatment result. It was shown that the macrodesign of the implant, specifically its shape (cone), its length and diameter, higher thread width and depth, lesser thread pitch and higher numbers of thread turns influence the primary stability. Specifically these characteristics, according to our opinion, assure the success of dental implantation.