Hadaate Ullah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hadaate Ullah has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abdullah Yahya Mohammed Muaad
Department of Studies in Computer Science, University of Mysore, Manasagangothri, Mysore 570006, India
1 shared publication - Belal Bin Heyat
School of Engineering, Westlake University, Hangzhou, China
1 shared publication - Dakun Lai
School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
1 shared publication - Faijan Akhtar
Medical Research Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences Southern Medical University Guangzhou China
1 shared publication Min Gao
State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, Sichuan, China
1 shared publicationSajjatul Islam
College of Computer Science, Data Intelligence and Computing Art Lab, Sichuan University, Chengdu 610065, China
1 shared publication
Latest Publications
- Open Access
- 29 September 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-23
An End-to-End Cardiac Arrhythmia Recognition Method with an Effective DenseNet Model on Imbalanced Datasets Using ECG Signal
Electrocardiography (ECG) is a well-known noninvasive technique in medical science that provides information about the hearts rhythm and current conditions. Automatic ECG arrhythmia diagnosis relieves doctors workload and improves diagnosis effectiveness and efficiency. This study proposes an automatic end-to-end 2D CNN (two-dimensional convolution neural networks) deep learning method with an effective DenseNet model for addressing arrhythmias recognition. To begin, the proposed model is trained and evaluated on the 97720 and 141404 beat images extracted from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia and St. Petersburg Institute of Cardiological Technics (INCART) datasets (both are imbalanced class datasets) using a stratified 5-fold evaluation strategy. The data is classified into four groups: N (normal), V (ventricular ectopic), S (supraventricular ectopic), and F (fusion), based on the Association for the Advancement of Medical Instrumentation® (AAMI). The experimental results show that the proposed model outperforms state-of-the-art models for recognizing arrhythmias, with the accuracy of 99.80 and 99.63, precision of 98.34 and 98.94, and F1-score of 98.91 and 98.91 on the MIT-BIH arrhythmia and INCART datasets, respectively. Using a transfer learning mechanism, the proposed model is also evaluated with only five individuals of supraventricular MIT-BIH arrhythmia and five individuals of European ST-T datasets (both of which are also class imbalanced) and achieved satisfactory results. So, the proposed model is more generalized and could be a prosperous solution for arrhythmias recognition from class imbalance datasets in real-life applications.
- 29 September 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-23
Open AccessAn End-to-End Cardiac Arrhythmia Recognition Method with an Effective DenseNet Model on Imbalanced Datasets Using ECG Signal
Electrocardiography (ECG) is a well-known noninvasive technique in medical science that provides information about the hearts rhythm and current conditions. Automatic ECG arrhythmia diagnosis relieves doctors workload and improves diagnosis effectiveness and efficiency. This study proposes an automatic end-to-end 2D CNN (two-dimensional convolution neural networks) deep learning method with an effective DenseNet model for addressing arrhythmias recognition. To begin, the proposed model is trained and evaluated on the 97720 and 141404 beat images extracted from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia and St. Petersburg Institute of Cardiological Technics (INCART) datasets (both are imbalanced class datasets) using a stratified 5-fold evaluation strategy. The data is classified into four groups: N (normal), V (ventricular ectopic), S (supraventricular ectopic), and F (fusion), based on the Association for the Advancement of Medical Instrumentation® (AAMI). The experimental results show that the proposed model outperforms state-of-the-art models for recognizing arrhythmias, with the accuracy of 99.80 and 99.63, precision of 98.34 and 98.94, and F1-score of 98.91 and 98.91 on the MIT-BIH arrhythmia and INCART datasets, respectively. Using a transfer learning mechanism, the proposed model is also evaluated with only five individuals of supraventricular MIT-BIH arrhythmia and five individuals of European ST-T datasets (both of which are also class imbalanced) and achieved satisfactory results. So, the proposed model is more generalized and could be a prosperous solution for arrhythmias recognition from class imbalance datasets in real-life applications.