ESErik Sandblom

Erik Sandblom

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Erik Sandblom has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Anthony P. Farrell

    Faculty of Agricultural Sciences and Department of Zoology, University of British Columbia, Vancouver, BC, V6T 1Z4, Canada

    1 shared publication
  • Guy Claireaux

    Centre de Recherche sur les Ecosystèmes Marins et Aquacoles(CNRS-IFREMER), Place du Séminaire, F-17137, L'Houmeau,France

    1 shared publication
  • Jordi Altimiras

    Department of Biology, Institute of Physics and Measurement Technology,Linköpings Universitet, S-58183 Linköping, Sweden

    1 shared publication
  • Michael Axelsson

    Department of Zoology, Göteborg University, Box 463, S-405 30 Göteborg, Sweden

    1 shared publication

Latest Publications

  • Open Access

    Cardiac preload and venous return in swimming sea bass (Dicentrarchus labraxL.)

    by Erik Sandblom, Anthony P. Farrell, Jordi Altimiras, Michael Axelsson, Guy Claireaux

    SUMMARY: Cardiac preload (central venous pressure, Pcv), mean circulatory filling pressure (MCFP), dorsal aortic blood pressure(Pda) and relative cardiac output(Q̇) were measured in sea bass(Dicentrarchus labrax) at rest and while swimming at 1 and 2 BL s-1. MCFP, an index of venous capacitance and the upstream venous pressure driving the return of venous blood to the heart, was measured as the plateau in Pcv during ventral aortic occlusion. Compared with resting values, swimming at 1 and 2 BLs-1 increased Q̇ (by 15±1.5 and 38±6.5%, respectively), Pcv (from 0.11±0.01 kPa to 0.12±0.01 and 0.16±0.02 kPa,respectively), MCFP (from 0.27±0.02 kPa to 0.31±0.02 and 0.40±0.04 kPa, respectively) and the calculated pressure gradient for venous return (ΔPv, from 0.16±0.01 kPa to 0.18±0.02 and 0.24±0.02 kPa, respectively), but not Pda. In spite of an increased preload, the increase in Q̇ was exclusively mediated by an increased heart rate (fh, from 80±4 beats min-1 to 88±4 and 103±3 beats min-1,respectively), and stroke volume (Vs) remained unchanged. Prazosin treatment (1 mg kg-1Mb) abolished pressure and flow changes during swimming at 1 BL s-1, but not 2 BL s-1, indicating that other control systems besides an α-adrenoceptor control are involved. This study is the first to address the control of venous capacitance in swimming fish. It questions the generality that increased Q̇ during swimming is regulated primarily through Vs and shows that an increased cardiac filling pressure does not necessarily lead to an increased Vs in fish, but may instead compensate for a reduced cardiac filling time.