Viola Bader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Viola Bader has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Fabian Niess
High Field MR Center, Department of Biomedical Imaging and Image‐guided Therapy Medical University of Vienna Vienna Austria
7 shared publications - Wolfgang Bogner
High Field MR Center, Department of Biomedical Imaging and Image‐guided Therapy Medical University of Vienna Vienna Austria
6 shared publications - Bernhard Strasser
High Field MR Center, Department of Biomedical Imaging and Image‐guided Therapy Medical University of Vienna Vienna Austria
4 shared publications - Stanislav Motyka
High Field MR Center, Department of Biomedical Imaging and Image‐guided Therapy Medical University of Vienna Vienna Austria
4 shared publications Aaron Osburg
High‐field MR Center, Department of Biomedical Imaging and Image‐guided Therapy Medical University of Vienna Vienna Austria
3 shared publicationsAnna Duguid
High‐field MR Center, Department of Biomedical Imaging and Image‐guided Therapy Medical University of Vienna Vienna Austria
3 shared publications
Latest Publications
- Open Access
- 20 November 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 40 (1)
Deuterium Metabolic Imaging‐Based Methods for Assessment of the Hepatocellular Lipid Content
As the liver is one of the key organs in the regulation of the lipid metabolism, it is of high interest to get detailed insights into physiological pathways and a better understanding of pathologies. This can be achieved by quantifying liver lipids using proton magnetic resonance spectroscopy ( 1 H‐MRS), for example. Deuterium metabolic imaging (DMI) offers a new way to derive the hepatic content of lipids (HCL), enabling dynamic studies with the administration of deuterated substances. The present study is a first step towards this goal, demonstrating successful DMI‐based HCL assessment without deuterium enrichment. Therefore, two different spatial encoding schemes for magnetic resonance spectroscopic imaging (MRSI) were applied: conventional phase encoding (PHE) and concentric ring trajectories (CRT). The results are in good agreement with a well‐established 1 H‐MRS technique, with Pearson correlation coefficients of 0.82 and 0.84 for the methylene only content and linear regression coefficients of 0.85 and 0.75 for the thereof derived HCL for both PHE and CRT, respectively. The feasibility of assessing the naturally abundant deuterium liver lipids with DMI lays the foundation for dynamic studies using 2 H‐enriched tracers in order to investigate the hepatic lipid metabolism in more detail as an accompanying method to 1 H‐based techniques.
- 20 November 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 40 (1)
Open AccessDeuterium Metabolic Imaging‐Based Methods for Assessment of the Hepatocellular Lipid Content
As the liver is one of the key organs in the regulation of the lipid metabolism, it is of high interest to get detailed insights into physiological pathways and a better understanding of pathologies. This can be achieved by quantifying liver lipids using proton magnetic resonance spectroscopy ( 1 H‐MRS), for example. Deuterium metabolic imaging (DMI) offers a new way to derive the hepatic content of lipids (HCL), enabling dynamic studies with the administration of deuterated substances. The present study is a first step towards this goal, demonstrating successful DMI‐based HCL assessment without deuterium enrichment. Therefore, two different spatial encoding schemes for magnetic resonance spectroscopic imaging (MRSI) were applied: conventional phase encoding (PHE) and concentric ring trajectories (CRT). The results are in good agreement with a well‐established 1 H‐MRS technique, with Pearson correlation coefficients of 0.82 and 0.84 for the methylene only content and linear regression coefficients of 0.85 and 0.75 for the thereof derived HCL for both PHE and CRT, respectively. The feasibility of assessing the naturally abundant deuterium liver lipids with DMI lays the foundation for dynamic studies using 2 H‐enriched tracers in order to investigate the hepatic lipid metabolism in more detail as an accompanying method to 1 H‐based techniques.
- Open Access
Experimental hypoxia to probe neuro-metabolic and vascular dysregulation in ME/CFS: a multimodal proof-of-concept MRI study
Background Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) is a poorly understood, debilitating multisystem condition. Converging evidence implicates impaired cellular bioenergetics, neuroinflammation and defective neurovascular coupling that may manifest as "virtual hypoxia" only under physiological stress. Methods We performed a single-session multimodal 3T MRI study combining brain volumetry, arterial spin labelling (ASL) and multivoxel proton magnetic resonance spectroscopy under normoxia and two controlled hypoxic challenges (oxygen saturation 87 ± 3%) in 26 ME/CFS patients and 27 age- and sex-matched healthy controls. Results After intracranial-volume normalization, patients showed a reduced brainstem volume (1.46 0.14 vs. 1.55 ± 0.18 % of eTIV; p = 0.013, FDR-p = 0.039), whereas deep grey matter and whole-brain parenchymal fraction did not differ between groups. Whole-brain cerebral blood flow (CBF) rose under hypoxia in both groups (controls +4.8 ± 13.0%, patients +3.7 ± 11.7%), with greater initial inter-individual variability in patients (patient-to-control variance ratio up to 6.94; FDR-p = 0.001). Thalamic lactate-to-creatine (Lac/tCr) ratios increased with hypoxia in controls (FDR-p = 0.028) but were already elevated at normoxia in patients (0.171 vs. 0.135; FDR-p = 0.021) and did not rise further (FDR-p = 0.38). In exploratory analyses, patients showed exaggerated inverse coupling between thalamic total N-acetylaspartate (tNAA/tCr) and white-matter CBF. Conclusions These findings provide in vivo evidence of impaired neuro-metabolic and vascular adaptive capacity in ME/CFS, supporting the virtual hypoxia hypothesis and highlighting candidate imaging markers for stratification that warrant validation.
Open AccessExperimental hypoxia to probe neuro-metabolic and vascular dysregulation in ME/CFS: a multimodal proof-of-concept MRI study
Background Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS) is a poorly understood, debilitating multisystem condition. Converging evidence implicates impaired cellular bioenergetics, neuroinflammation and defective neurovascular coupling that may manifest as "virtual hypoxia" only under physiological stress. Methods We performed a single-session multimodal 3T MRI study combining brain volumetry, arterial spin labelling (ASL) and multivoxel proton magnetic resonance spectroscopy under normoxia and two controlled hypoxic challenges (oxygen saturation 87 ± 3%) in 26 ME/CFS patients and 27 age- and sex-matched healthy controls. Results After intracranial-volume normalization, patients showed a reduced brainstem volume (1.46 0.14 vs. 1.55 ± 0.18 % of eTIV; p = 0.013, FDR-p = 0.039), whereas deep grey matter and whole-brain parenchymal fraction did not differ between groups. Whole-brain cerebral blood flow (CBF) rose under hypoxia in both groups (controls +4.8 ± 13.0%, patients +3.7 ± 11.7%), with greater initial inter-individual variability in patients (patient-to-control variance ratio up to 6.94; FDR-p = 0.001). Thalamic lactate-to-creatine (Lac/tCr) ratios increased with hypoxia in controls (FDR-p = 0.028) but were already elevated at normoxia in patients (0.171 vs. 0.135; FDR-p = 0.021) and did not rise further (FDR-p = 0.38). In exploratory analyses, patients showed exaggerated inverse coupling between thalamic total N-acetylaspartate (tNAA/tCr) and white-matter CBF. Conclusions These findings provide in vivo evidence of impaired neuro-metabolic and vascular adaptive capacity in ME/CFS, supporting the virtual hypoxia hypothesis and highlighting candidate imaging markers for stratification that warrant validation.
- Open Access
- 2 December 2025
- Published by Elsevier in NeuroImage
- Vol. 324, 121632
A deep autoencoder for fast spectral–temporal fitting of dynamic deuterium metabolic imaging data at 7T
- 2 December 2025
- Published by Elsevier in NeuroImage
- Vol. 324, 121632
Open AccessA deep autoencoder for fast spectral–temporal fitting of dynamic deuterium metabolic imaging data at 7T
- Open Access
A Deep Autoencoder for Fast Spectral-Temporal Fitting of Dynamic Deuterium Metabolic Imaging Data at 7T
Deuterium metabolic imaging (DMI) is a non-invasive magnetic resonance spectroscopic imaging technique enabling in vivo mapping of glucose metabolism. Dynamic DMI provides time-resolved metabolite maps and allows spatially resolved fitting of metabolic models to capture metabolite concentration dynamics. However, conventional fitting tools often require long processing times for high-resolution datasets, limiting their practical utility. To address this bottleneck, we propose a deep autoencoder (DAE) for rapid spectral–temporal fitting of dynamic DMI data, supporting arbitrary parametric model constraints to describe metabolite concentration dynamics. The DAE was benchmarked against spectral-temporal fitting using FSL-MRS and LCModel. Fitting accuracy was evaluated on in vivo and synthetic whole-brain dynamic DMI data acquired at 7T using Bland-Altman metrics, Pearson correlation coefficients, structural similarity index measures, and root mean squared errors for both metabolite concentrations and model constraint parameters. The DAE achieved processing times of 0.29 ms per voxel, corresponding to an acceleration of more than three orders of magnitude compared to LCModel/FSL-MRS (0.55/0.65 s per voxel). On in vivo data, it showed excellent agreement with LCModel, and on synthetic data, it consistently outperformed both reference methods across all evaluation metrics. The proposed DAE enables accurate spectral-temporal fitting for whole-brain dynamic DMI scans within less than a second, matching or exceeding the performance of conventional state-of-the-art fitting methods. This makes it a promising tool for integration into efficient post-processing pipelines for research and clinical DMI workflows.
Open AccessA Deep Autoencoder for Fast Spectral-Temporal Fitting of Dynamic Deuterium Metabolic Imaging Data at 7T
Deuterium metabolic imaging (DMI) is a non-invasive magnetic resonance spectroscopic imaging technique enabling in vivo mapping of glucose metabolism. Dynamic DMI provides time-resolved metabolite maps and allows spatially resolved fitting of metabolic models to capture metabolite concentration dynamics. However, conventional fitting tools often require long processing times for high-resolution datasets, limiting their practical utility. To address this bottleneck, we propose a deep autoencoder (DAE) for rapid spectral–temporal fitting of dynamic DMI data, supporting arbitrary parametric model constraints to describe metabolite concentration dynamics. The DAE was benchmarked against spectral-temporal fitting using FSL-MRS and LCModel. Fitting accuracy was evaluated on in vivo and synthetic whole-brain dynamic DMI data acquired at 7T using Bland-Altman metrics, Pearson correlation coefficients, structural similarity index measures, and root mean squared errors for both metabolite concentrations and model constraint parameters. The DAE achieved processing times of 0.29 ms per voxel, corresponding to an acceleration of more than three orders of magnitude compared to LCModel/FSL-MRS (0.55/0.65 s per voxel). On in vivo data, it showed excellent agreement with LCModel, and on synthetic data, it consistently outperformed both reference methods across all evaluation metrics. The proposed DAE enables accurate spectral-temporal fitting for whole-brain dynamic DMI scans within less than a second, matching or exceeding the performance of conventional state-of-the-art fitting methods. This makes it a promising tool for integration into efficient post-processing pipelines for research and clinical DMI workflows.
- Open Access
- 9 September 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (10) , e70139
Feasibility of High‐Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T
The human kidneys play a pivotal role in regulating blood pressure, water, and salt homeostasis, but assessment of renal function typically requires invasive methods. Deuterium metabolic imaging (DMI) is a novel, noninvasive technique for mapping tissue‐specific uptake and metabolism of deuterium‐labeled tracers. This study evaluates the feasibility of renal DMI at 7‐Tesla (7T) to track deuterium‐labeled tracers with high spatial and temporal resolution, aiming to establish a foundation for potential clinical applications in the noninvasive investigation of renal physiology and pathophysiology. Five healthy participants (3 m/2f) underwent renal DMI at 7T using MR spectroscopic imaging with concentric ring trajectory sampling. Two subjects participated in dynamic DMI experiments after oral administration of deuterium‐labeled water (D2O, 0.25, and 0.5 mL/kg) or glucose ([6,6′‐2H]‐Glc, 0.5 g/kg) following 12 h overnight fasting. Continuous glucose monitoring (CGM) was performed using FreeStyle Libre 3 and compared to renal 2H‐glucose levels. Three‐dimensional maps of 2H‐water and 2H‐glucose were acquired every ∼8.5 min at isotropic resolutions of ∼1.8 and ∼0.9 mL, respectively. Tensor Marchenko‐Pastur Principal Component Analysis (tMPPCA) was used for spectral denoising. Renal DMI successfully generated dynamic 3D maps of 2H‐water and 2H‐glucose with improved spatial resolution compared to previous studies. Following D2O ingestion, 2H‐water dynamics (0‐60 min) and steady‐state levels (> 90 min) were assessed. Following 2H‐glucose ingestion, renal 2H‐Glc concentrations peaked at 1.8 ± 1.0 mM on average over both kidneys, and overall dynamics aligned with interstitial glucose levels simultaneously assessed using CGM sensor. This study demonstrates the feasibility of dynamic renal DMI with improved spatial resolution to noninvasively map multiple 2H‐labeled tracers in the human kidney at 7T. Future improvements in signal mitigation and intravenous tracer administration could enhance its clinical utility, potentially aiding in the evaluation of metabolic effects of novel therapies like SGLT‐2 inhibitors for personalized treatment strategies.
- 9 September 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (10) , e70139
Open AccessFeasibility of High‐Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T
The human kidneys play a pivotal role in regulating blood pressure, water, and salt homeostasis, but assessment of renal function typically requires invasive methods. Deuterium metabolic imaging (DMI) is a novel, noninvasive technique for mapping tissue‐specific uptake and metabolism of deuterium‐labeled tracers. This study evaluates the feasibility of renal DMI at 7‐Tesla (7T) to track deuterium‐labeled tracers with high spatial and temporal resolution, aiming to establish a foundation for potential clinical applications in the noninvasive investigation of renal physiology and pathophysiology. Five healthy participants (3 m/2f) underwent renal DMI at 7T using MR spectroscopic imaging with concentric ring trajectory sampling. Two subjects participated in dynamic DMI experiments after oral administration of deuterium‐labeled water (D2O, 0.25, and 0.5 mL/kg) or glucose ([6,6′‐2H]‐Glc, 0.5 g/kg) following 12 h overnight fasting. Continuous glucose monitoring (CGM) was performed using FreeStyle Libre 3 and compared to renal 2H‐glucose levels. Three‐dimensional maps of 2H‐water and 2H‐glucose were acquired every ∼8.5 min at isotropic resolutions of ∼1.8 and ∼0.9 mL, respectively. Tensor Marchenko‐Pastur Principal Component Analysis (tMPPCA) was used for spectral denoising. Renal DMI successfully generated dynamic 3D maps of 2H‐water and 2H‐glucose with improved spatial resolution compared to previous studies. Following D2O ingestion, 2H‐water dynamics (0‐60 min) and steady‐state levels (> 90 min) were assessed. Following 2H‐glucose ingestion, renal 2H‐Glc concentrations peaked at 1.8 ± 1.0 mM on average over both kidneys, and overall dynamics aligned with interstitial glucose levels simultaneously assessed using CGM sensor. This study demonstrates the feasibility of dynamic renal DMI with improved spatial resolution to noninvasively map multiple 2H‐labeled tracers in the human kidney at 7T. Future improvements in signal mitigation and intravenous tracer administration could enhance its clinical utility, potentially aiding in the evaluation of metabolic effects of novel therapies like SGLT‐2 inhibitors for personalized treatment strategies.
- Open Access
- 31 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (10) , e70125
Comparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T
Dynamic deuterium (2H)‐MRSI enables mapping of metabolic fluxes in vivo, but its sensitivity is hampered by the low 2H gyromagnetic ratio and 2H‐labelled metabolite concentrations. Low‐rank denoising can enhance MRSI sensitivity by separating signal from noise. Several methods have been proposed, but the optimal approach for dynamic 2H‐MRSI remains unclear. This work compares six low‐rank denoising methods for dynamic 2H‐MRSI: four variations of spatiospectral partial separability (PS)—Global PS, Local PS, Stacked PS and SPectral and temporal INtegration for SVD (SPIN‐SVD)—as well as global–local higher order singular value decomposition (GL‐HOSVD) and tensor Marchenko–Pastur principal component analysis (tMPPCA). Performance was evaluated using realistic 2H‐MRSI brain simulations across a range of noise and B0 inhomogeneity levels, including a lesion model featuring focal metabolic alteration, and in vivo data. For simulations at the in vivo SNR and B0 level, the concentration root‐mean‐square errors (RMSE) of the fitted metabolite maps against gold standard maps were reduced by 29.3%, 24.4%, 20.2%, 33.4%, 23.5% and 21.9% following denoising with Global PS, Local PS, Stacked PS, SPIN‐SVD, GL‐HOSVD and tMPPCA, respectively. Across all simulated noise levels and all but the highest B0 inhomogeneity level, SPIN‐SVD achieved the lowest concentration RMSE and best preserved spatial distributions of 2H‐labelled water (HDO) and lactate (Lac), including lesion‐associated changes. While Global PS and Stacked PS reduced noise variance, they failed to preserve signal variations in simulated and in vivo data. SPIN‐SVD, GL‐HOSVD and tMPPCA reduced noise in vivo while maintaining spatial and temporal metabolite variations. GL‐HOSVD and tMPPCA performed similarly, with tMPPCA preferred for its computational efficiency. Both SPIN‐SVD and tMPPCA are suitable for denoising dynamic 2H‐MRSI, with SPIN‐SVD preferable for clinical applications owing to its simple implementation and superior preservation of local metabolic alterations, and tMPPCA better suited for absolute quantification of very low SNR metabolites.
- 31 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (10) , e70125
Open AccessComparison of Low‐Rank Denoising Methods for Dynamic Deuterium MRSI at 7 T
Dynamic deuterium (2H)‐MRSI enables mapping of metabolic fluxes in vivo, but its sensitivity is hampered by the low 2H gyromagnetic ratio and 2H‐labelled metabolite concentrations. Low‐rank denoising can enhance MRSI sensitivity by separating signal from noise. Several methods have been proposed, but the optimal approach for dynamic 2H‐MRSI remains unclear. This work compares six low‐rank denoising methods for dynamic 2H‐MRSI: four variations of spatiospectral partial separability (PS)—Global PS, Local PS, Stacked PS and SPectral and temporal INtegration for SVD (SPIN‐SVD)—as well as global–local higher order singular value decomposition (GL‐HOSVD) and tensor Marchenko–Pastur principal component analysis (tMPPCA). Performance was evaluated using realistic 2H‐MRSI brain simulations across a range of noise and B0 inhomogeneity levels, including a lesion model featuring focal metabolic alteration, and in vivo data. For simulations at the in vivo SNR and B0 level, the concentration root‐mean‐square errors (RMSE) of the fitted metabolite maps against gold standard maps were reduced by 29.3%, 24.4%, 20.2%, 33.4%, 23.5% and 21.9% following denoising with Global PS, Local PS, Stacked PS, SPIN‐SVD, GL‐HOSVD and tMPPCA, respectively. Across all simulated noise levels and all but the highest B0 inhomogeneity level, SPIN‐SVD achieved the lowest concentration RMSE and best preserved spatial distributions of 2H‐labelled water (HDO) and lactate (Lac), including lesion‐associated changes. While Global PS and Stacked PS reduced noise variance, they failed to preserve signal variations in simulated and in vivo data. SPIN‐SVD, GL‐HOSVD and tMPPCA reduced noise in vivo while maintaining spatial and temporal metabolite variations. GL‐HOSVD and tMPPCA performed similarly, with tMPPCA preferred for its computational efficiency. Both SPIN‐SVD and tMPPCA are suitable for denoising dynamic 2H‐MRSI, with SPIN‐SVD preferable for clinical applications owing to its simple implementation and superior preservation of local metabolic alterations, and tMPPCA better suited for absolute quantification of very low SNR metabolites.
- Open Access
- 19 December 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (2) , e5311
Concentric Ring Trajectory Sampling With k‐Space Reordering Enables Assessment of Tissue‐Specific T1 and T2 Relaxation for 2H‐Labeled Substrates in the Human Brain at 7 T
Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium‐labeled (2H) glucose as non‐invasive tracer. Reliable concentration estimation of 2H‐Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue‐specific T1 and T2 relaxation times (e.g., in gray and white matter) have not been determined. Such measurements are time‐consuming and particularly challenging in the presence of dynamically changing metabolite levels (e.g. 2H Glc and 2H Glx).This study aimed to assess T1 and T2 relaxation times of deuterated resonances, i.e., water, Glc and Glx in human gray and white matter using inversion recovery and Hahn spin‐echo 2H MRSI (magnetic resonance spectroscopic imaging), respectively, with non‐Cartesian concentric ring trajectory readout (CRT) including specific k‐space reordering at 7 T. The sequence was validated using phantom measurements and all results were compared to unlocalized acquisitions. Thirteen healthy volunteers participated in the study, with 10 of them scanned ~90 min after oral administration of 0.8 g/kg [6,6′‐2H]‐glucose. Significantly different T1 and T2 relaxation was observed between GM and WM for 2H water (T1GM/WM/unlocalized = 358 ± 21/328 ± 12/335 m ± 6 ms, p = 0.01) and 2H Glx (T2GM/WM/unlocalized = 37 ± 2/35 ± 2/33 ± 3 ms, p = 0.02), respectively, consistent with unlocalized acquisitions. No significant regional differences were found for 2H water (T2GM/WM/unlocalized = 36 ± 2/34 ± 2/31 ± 2 ms, p = 0.08), 2H Glc (T1GM/WM/unlocalized = 70 ± 5/73 ± 4/80 ± 5 ms, p = 0.13; T2GM/WM/unlocalized = 36 ± 1/34 ± 2/34 ± 2 ms, p = 0.24) and Glx (T1GM/WM/unlocalized = 172 ± 15/172 ± 12/165 ± 11 ms, p = 1.00).Knowledge of tissue‐specific relaxation times can enhance the accuracy of concentration estimation and metabolic flux rates in future studies, potentially improving our understanding of various brain diseases such as cancer, neurodegenerative diseases or diabetes, which are often linked to impaired glucose metabolism.
- 19 December 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (2) , e5311
Open AccessConcentric Ring Trajectory Sampling With k‐Space Reordering Enables Assessment of Tissue‐Specific T1 and T2 Relaxation for 2H‐Labeled Substrates in the Human Brain at 7 T
Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium‐labeled (2H) glucose as non‐invasive tracer. Reliable concentration estimation of 2H‐Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue‐specific T1 and T2 relaxation times (e.g., in gray and white matter) have not been determined. Such measurements are time‐consuming and particularly challenging in the presence of dynamically changing metabolite levels (e.g. 2H Glc and 2H Glx).This study aimed to assess T1 and T2 relaxation times of deuterated resonances, i.e., water, Glc and Glx in human gray and white matter using inversion recovery and Hahn spin‐echo 2H MRSI (magnetic resonance spectroscopic imaging), respectively, with non‐Cartesian concentric ring trajectory readout (CRT) including specific k‐space reordering at 7 T. The sequence was validated using phantom measurements and all results were compared to unlocalized acquisitions. Thirteen healthy volunteers participated in the study, with 10 of them scanned ~90 min after oral administration of 0.8 g/kg [6,6′‐2H]‐glucose. Significantly different T1 and T2 relaxation was observed between GM and WM for 2H water (T1GM/WM/unlocalized = 358 ± 21/328 ± 12/335 m ± 6 ms, p = 0.01) and 2H Glx (T2GM/WM/unlocalized = 37 ± 2/35 ± 2/33 ± 3 ms, p = 0.02), respectively, consistent with unlocalized acquisitions. No significant regional differences were found for 2H water (T2GM/WM/unlocalized = 36 ± 2/34 ± 2/31 ± 2 ms, p = 0.08), 2H Glc (T1GM/WM/unlocalized = 70 ± 5/73 ± 4/80 ± 5 ms, p = 0.13; T2GM/WM/unlocalized = 36 ± 1/34 ± 2/34 ± 2 ms, p = 0.24) and Glx (T1GM/WM/unlocalized = 172 ± 15/172 ± 12/165 ± 11 ms, p = 1.00).Knowledge of tissue‐specific relaxation times can enhance the accuracy of concentration estimation and metabolic flux rates in future studies, potentially improving our understanding of various brain diseases such as cancer, neurodegenerative diseases or diabetes, which are often linked to impaired glucose metabolism.