Silong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Silong Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoping Ouyang
School of Physics and Astronomy, Beijing Normal University 4 , Beijing 100875
4 shared publications - Liang Chen
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi’an 710024, China
3 shared publications - Fangbao Wang
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi’an 710024, China
2 shared publications - Leidang Zhou
National Key Laboratory for High Energy Pulsed Power, School of Microelectronics, Xi'an Jiaotong University 1 , Xi'an 710049
2 shared publications - Naizhe Zhao
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi’an 710024, China
2 shared publications - Yang Li
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi’an 710024, China
2 shared publications
Latest Publications
- Open Access
Flexible Cs3Cu2I5 Nanocrystal Thin-Film Scintillators for Efficient α-Particle Detection
Thin-film detection technology plays a significant role in particle physics, X-ray imaging and radiation monitoring. In this paper, the detection capability of a Cs3Cu2I5 thin-film scintillator toward α particles is investigated. The flexible thin-film scintillator is fabricated by a facile and cost-effective in situ strategy, exhibiting excellent scintillation properties. Upon α-particle excitation, the light yield of the Cs3Cu2I5 thin-film is 2400 photons/MeV, which greatly benefits its application for single-particle events detection. Moreover, it shows linear energy response within the range of 4.7–5.5 MeV and moderate decay time of 667 ns. We further explored the cryogenic scintillation performance of Cs3Cu2I5@PMMA film. As the temperature decreases from 300 K to 50 K, its light yield gradually increases to 1.3 fold of its original value, while its decay time remains almost unchanged. This scintillator film also shows excellent low-temperature stability and flexible operational stability. This work demonstrates the great potential of the Cs3Cu2I5@PMMA film for the practical utilization in α-particle detection application.
Open AccessFlexible Cs3Cu2I5 Nanocrystal Thin-Film Scintillators for Efficient α-Particle Detection
Thin-film detection technology plays a significant role in particle physics, X-ray imaging and radiation monitoring. In this paper, the detection capability of a Cs3Cu2I5 thin-film scintillator toward α particles is investigated. The flexible thin-film scintillator is fabricated by a facile and cost-effective in situ strategy, exhibiting excellent scintillation properties. Upon α-particle excitation, the light yield of the Cs3Cu2I5 thin-film is 2400 photons/MeV, which greatly benefits its application for single-particle events detection. Moreover, it shows linear energy response within the range of 4.7–5.5 MeV and moderate decay time of 667 ns. We further explored the cryogenic scintillation performance of Cs3Cu2I5@PMMA film. As the temperature decreases from 300 K to 50 K, its light yield gradually increases to 1.3 fold of its original value, while its decay time remains almost unchanged. This scintillator film also shows excellent low-temperature stability and flexible operational stability. This work demonstrates the great potential of the Cs3Cu2I5@PMMA film for the practical utilization in α-particle detection application.
- Open Access
Scintillation Properties of CsPbBr3 Quantum Dot Film-Enhanced Ga:ZnO Wafer and Its Applications
In high energy density physics, the demand for precise detection of nanosecond-level fast physical processes is high. Ga:ZnO (GZO), GaN, and other fast scintillators are widely used in pulsed signal detection. However, many of them, especially wide-bandgap materials, still face issues of low luminous intensity and significant self-absorption. Therefore, an enhanced method was proposed to tune the wavelength of materials via coating perovskite quantum dot (QD) films. Three-layer samples based on GZO were primarily investigated and characterized. Radioluminescence (RL) spectra from each face of the samples, as well as their decay times, were obtained. Lower temperatures further enhanced the luminous intensity of the samples. Its overall luminous intensity increased by 2.7 times at 60 K compared to room temperature. The changes in the RL processes caused by perovskite QD and low temperatures were discussed using the light tuning and transporting model. In addition, an experiment under a pico-second electron beam was conducted to verify their pulse response and decay time. Accordingly, the samples were successfully applied in beam state monitoring of nanosecond pulsed proton beams, which indicates that GZO wafer coating with perovskite QD films has broad application prospects in pulsed radiation detection.
Open AccessScintillation Properties of CsPbBr3 Quantum Dot Film-Enhanced Ga:ZnO Wafer and Its Applications
In high energy density physics, the demand for precise detection of nanosecond-level fast physical processes is high. Ga:ZnO (GZO), GaN, and other fast scintillators are widely used in pulsed signal detection. However, many of them, especially wide-bandgap materials, still face issues of low luminous intensity and significant self-absorption. Therefore, an enhanced method was proposed to tune the wavelength of materials via coating perovskite quantum dot (QD) films. Three-layer samples based on GZO were primarily investigated and characterized. Radioluminescence (RL) spectra from each face of the samples, as well as their decay times, were obtained. Lower temperatures further enhanced the luminous intensity of the samples. Its overall luminous intensity increased by 2.7 times at 60 K compared to room temperature. The changes in the RL processes caused by perovskite QD and low temperatures were discussed using the light tuning and transporting model. In addition, an experiment under a pico-second electron beam was conducted to verify their pulse response and decay time. Accordingly, the samples were successfully applied in beam state monitoring of nanosecond pulsed proton beams, which indicates that GZO wafer coating with perovskite QD films has broad application prospects in pulsed radiation detection.
- Open Access
- 14 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 339
Performance Degradation of Ga2O3-Based X-Ray Detector Under Gamma-Ray Irradiation
X-ray response performances of a p-NiO/β-Ga2O3 hetero-junction diode (HJD) X-ray detector were studied before and after γ-ray irradiation at −200 V, with a total dose of 13.5 kGy(Si). The response performances of the HJD X-ray detector were influenced by the trap-assistant conductive process of the HJD under reverse bias, which exhibited an increasing net (response) current, nonlinearity, and a long response time. After irradiation, the Poole–Frenkel emission (PFE) dominated the leakage current of HJDs due to the higher electric field caused by the increased net carrier concentration of β-Ga2O3. This conductive process weakened the performance of the HJD X-ray detector in terms of sensitivity, output linearity, and response speed. This study provided valuable insights into the radiation damage and performance degradation mechanisms of Ga2O3-based radiation detectors and offered guidance on improving the reliability and stability of these radiation detectors.
- 14 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 339
Open AccessPerformance Degradation of Ga2O3-Based X-Ray Detector Under Gamma-Ray Irradiation
X-ray response performances of a p-NiO/β-Ga2O3 hetero-junction diode (HJD) X-ray detector were studied before and after γ-ray irradiation at −200 V, with a total dose of 13.5 kGy(Si). The response performances of the HJD X-ray detector were influenced by the trap-assistant conductive process of the HJD under reverse bias, which exhibited an increasing net (response) current, nonlinearity, and a long response time. After irradiation, the Poole–Frenkel emission (PFE) dominated the leakage current of HJDs due to the higher electric field caused by the increased net carrier concentration of β-Ga2O3. This conductive process weakened the performance of the HJD X-ray detector in terms of sensitivity, output linearity, and response speed. This study provided valuable insights into the radiation damage and performance degradation mechanisms of Ga2O3-based radiation detectors and offered guidance on improving the reliability and stability of these radiation detectors.
- Open Access
- 24 December 2024
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 2
X-Ray Performance of SiC NPN Radiation Detector
In this paper, a silicon carbide (SiC) phototransistor based on an open-base structure was fabricated and used as a radiation detector. In contrast to the exposed and thin sensitive region of traditional photo detectors, the sensitive region of the radiation detector was much thicker (30 μm), ensuring the high energy deposition of radiation particles. The response properties of the fabricated SiC npn radiation detector were characterized by high-energy X-ray illumination with a maximum X-ray photon energy of 30 keV. The SiC npn detector featured stable and clear response to the X-ray within 0.0766 Gy∙s−1 to 0.766 Gy∙s−1 below 300 V. Due to to the low leakage current of less than 1 nA and the fully depleted sensitive region, the bipolar-transistor-modeled SiC npn detector exhibited a clear common-emitter current gain of 5.85 at 200 V (under 0.383 Gy∙s−1), where the gain increased with bias voltage due to the Early effect and reached 7.55 at 300 V. In addition, the transient response of the SiC npn detector revealed a longer delay time than the SiC diode of the same size, which was associated with the larger effective capacitance of the npn structure. The npn detector with internal gain showed great potential in radiation detection.
- 24 December 2024
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 2
Open AccessX-Ray Performance of SiC NPN Radiation Detector
In this paper, a silicon carbide (SiC) phototransistor based on an open-base structure was fabricated and used as a radiation detector. In contrast to the exposed and thin sensitive region of traditional photo detectors, the sensitive region of the radiation detector was much thicker (30 μm), ensuring the high energy deposition of radiation particles. The response properties of the fabricated SiC npn radiation detector were characterized by high-energy X-ray illumination with a maximum X-ray photon energy of 30 keV. The SiC npn detector featured stable and clear response to the X-ray within 0.0766 Gy∙s−1 to 0.766 Gy∙s−1 below 300 V. Due to to the low leakage current of less than 1 nA and the fully depleted sensitive region, the bipolar-transistor-modeled SiC npn detector exhibited a clear common-emitter current gain of 5.85 at 200 V (under 0.383 Gy∙s−1), where the gain increased with bias voltage due to the Early effect and reached 7.55 at 300 V. In addition, the transient response of the SiC npn detector revealed a longer delay time than the SiC diode of the same size, which was associated with the larger effective capacitance of the npn structure. The npn detector with internal gain showed great potential in radiation detection.