CXChuangye Xu

Chuangye Xu

*This is an algorithmically generated author record based on publicly available information.

Chuangye Xu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    VentGuard: A Machine Learning-Based Real-Time Anomaly Detection and Early Warning System for Mechanical Ventilator Monitoring

    by Min Tan, Gaosheng Xie, Chuangye Xu, Shuangwei Wang, Jing Xiong

    Mechanical ventilation is a critical life-support intervention for patients with respiratory failure in intensive care units. However, timely detection of ventilator-related anomalies remains challenging due to the complexity of respiratory data streams. This paper presents VentGuard, a web-based platform that combines real-time data visualization with machine learning algorithms for automated anomaly detection in mechanical ventilator monitoring. Our system implements six unsupervised learning algorithms including Isolation Forest, One-Class SVM, and DBSCAN, enabling comparative analysis and flexible model deployment. We propose a ML-enhanced detection approach that augments traditional rule-based clinical thresholds with machine learning pattern recognition. Experimental evaluation on 8,115 real-world ventilator records demonstrates that ML enhancement achieves 78-89% anomaly detection rates, providing consistent improvements of 3-10 percentage points over rule-based baseline methods, with Isolation Forest and One-Class SVM showing the most stable performance across varying training data volumes. The system’s modular architecture supports configurable training and real-time alert generation, making it suitable for deployment in critical care environments.

  • NUMERICAL SIMULATION OF TRANSIENT EDGE VASCULAR RESPONSE THROUGH VIRTUAL STENTING DEPLOYMENT WITHIN PATIENT-SPECIFIC CORONARY ARTERIES

    by Chuangye Xu, Hang Su, Shuangwei Wang, Zhe Wang, Guifeng Gao, Xiujian Liu

    Late stent edge restenosis (SER) following percutaneous coronary intervention (PCI) remains a significant complication with unclear etiology. This study aims to investigate the transient edge vascular response (EVR) using virtual stenting technology. Methods: Six finite element analysis (FEA) models were constructed to simulate stenting procedures. Profiles of lumen diameter, ellipticity, and maximum principal stress (MPS) distribution of the vascular wall were calculated and analyzed at four typical time points: the initial state, post-balloon pre-dilation analysis, maximum stent expansion, and final configuration. Results: Balloon pre-dilation significantly increased lumen diameters in the stented segments but had a minimal impact on the nonstented segments. At maximum stent expansion, the diameter of the stented segments showed a substantial increase compared to the post-balloon pre-dilation phase. Subsequently, a reduction in diameter was observed the following recoil of the vascular wall. The ellipticity of stenotic segments decreased markedly at maximum stent expansion. Following balloon pre-dilation, the stress within the artery wall was relatively low and did not differ significantly between stented and nonstented segments. At maximum stent expansion, MPS was elevated in both the stented and nonstented segments, particularly near the stent end. In the final configuration, there was a significant reduction in MPS, especially in the stented sections. Conclusion: The virtual stenting method allows for the simulation of transient EVR and facilitates the analysis of geometric and biomechanical changes. This approach aids in understanding the mechanical factors involved in late SER.