Baozhen Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Baozhen Ren has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chang Wang
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
2 shared publications - Hui Li
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
2 shared publications - Yan Zhao
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
2 shared publications Chang Wang
1 shared publication- Hongliang Ren
The Chinese University of Hong Kong
1 shared publication Hui Li
1 shared publication
Latest Publications
- Open Access
- 12 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8020
Vessel Segmentation Based on a Channel-Attention U-Net Algorithm
Vessel segmentation is a fundamental task in medical image analysis and plays an important role in disease diagnosis and treatment assessment. However, existing segmentation methods often show limited adaptability to feature extraction from single-channel X-ray coronary angiograms, which restricts their performance in segmenting small vessels and low-contrast vascular regions. To address these limitations, this study proposes a Channel-Attention U-Net, termed CA-UNet, which integrates residual connections and a channel attention mechanism. Based on the conventional encoder–decoder architecture of U-Net, the proposed method introduces a residual-enhanced double-convolution block to alleviate gradient vanishing in deeper networks. In addition, a dual-pooling channel attention module is incorporated to enhance the selection of discriminative vascular features. Furthermore, the data loading, normalization, and augmentation strategies are optimized to improve the adaptability of the network to single-channel PGM grayscale images. Under three-fold out-of-fold evaluation, CA-UNet achieved the highest mean Dice coefficient (0.7450) and IoU (0.5972) among the evaluated models, while maintaining real-time-rate inference at 41.7 frames per second. These results indicate that CA-UNet provides an effective balance of segmentation accuracy, stability, and computational efficiency for vessel segmentation.
- 12 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8020
Open AccessVessel Segmentation Based on a Channel-Attention U-Net Algorithm
Vessel segmentation is a fundamental task in medical image analysis and plays an important role in disease diagnosis and treatment assessment. However, existing segmentation methods often show limited adaptability to feature extraction from single-channel X-ray coronary angiograms, which restricts their performance in segmenting small vessels and low-contrast vascular regions. To address these limitations, this study proposes a Channel-Attention U-Net, termed CA-UNet, which integrates residual connections and a channel attention mechanism. Based on the conventional encoder–decoder architecture of U-Net, the proposed method introduces a residual-enhanced double-convolution block to alleviate gradient vanishing in deeper networks. In addition, a dual-pooling channel attention module is incorporated to enhance the selection of discriminative vascular features. Furthermore, the data loading, normalization, and augmentation strategies are optimized to improve the adaptability of the network to single-channel PGM grayscale images. Under three-fold out-of-fold evaluation, CA-UNet achieved the highest mean Dice coefficient (0.7450) and IoU (0.5972) among the evaluated models, while maintaining real-time-rate inference at 41.7 frames per second. These results indicate that CA-UNet provides an effective balance of segmentation accuracy, stability, and computational efficiency for vessel segmentation.
- Open Access
- 31 March 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (4) , 229
A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors
Interventional robots play a crucial role in surgical procedures, where accurate force measurement is essential for enhancing safety. Compliant mechanisms utilize material deformation to achieve millinewton-scale force output and millimeter-level displacement with high repeatability. Motivated by this, we propose a method for measuring the catheter force by integrating a compliant mechanism and a sensor. First, we designed an operating force detection module. It comprises a double-parallelogram structure with four elastic units, a catheter drive module, and a sensor. The sensor connects the compliant mechanism to the base. Second, stiffness and gravity compensation models were established and validated experimentally. Finally, we constructed an experimental platform to evaluate the force measurement accuracy, drive accuracy, and real-time detection capability. Experimental results demonstrate that the proposed method achieves a maximum detection error of 0.1482 N, an average error of 0.0096 N, a resolution of 0.01 N, and an average axial delivery error of 0.8287 mm. Additionally, a master–slave control framework was developed, along with a master controller that manipulates the slave robot to deliver the catheter within a vascular phantom, while simultaneously displaying real-time force information via the human–computer interaction interface.
- 31 March 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (4) , 229
Open AccessA Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors
Interventional robots play a crucial role in surgical procedures, where accurate force measurement is essential for enhancing safety. Compliant mechanisms utilize material deformation to achieve millinewton-scale force output and millimeter-level displacement with high repeatability. Motivated by this, we propose a method for measuring the catheter force by integrating a compliant mechanism and a sensor. First, we designed an operating force detection module. It comprises a double-parallelogram structure with four elastic units, a catheter drive module, and a sensor. The sensor connects the compliant mechanism to the base. Second, stiffness and gravity compensation models were established and validated experimentally. Finally, we constructed an experimental platform to evaluate the force measurement accuracy, drive accuracy, and real-time detection capability. Experimental results demonstrate that the proposed method achieves a maximum detection error of 0.1482 N, an average error of 0.0096 N, a resolution of 0.01 N, and an average axial delivery error of 0.8287 mm. Additionally, a master–slave control framework was developed, along with a master controller that manipulates the slave robot to deliver the catheter within a vascular phantom, while simultaneously displaying real-time force information via the human–computer interaction interface.
- 25 December 2024
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 382
Multi-point bending operation force detection method of catheter-based on rotary clamping delivery
- 25 December 2024
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 382
Multi-point bending operation force detection method of catheter-based on rotary clamping delivery