M. LaCapra
Research Subjects
M. LaCapra has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Michael Rosenthal
Commonwealth Fusion Systems 2 , Devens, Massachusetts 01434
2 shared publications - J. N. Hawke
Commonwealth Fusion Systems 1 , Devens, Massachusetts 01434
2 shared publications - M. Silva Sa
Commonwealth Fusion Systems 2 , Devens, Massachusetts 01434
2 shared publications - Matthew L. Reinke
Commonwealth Fusion Systems , Devens, Massachusetts 01434
2 shared publications - R. Zubieta Lupo
Commonwealth Fusion Systems 1 , Devens, Massachusetts 01434
2 shared publications A. A. Saltos
Commonwealth Fusion Systems 1 , Devens, Massachusetts 01434
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Measurements for fusion power to demonstrate Q fus > 1 on SPARC (invited)
The SPARC tokamak’s primary goal in the first operational campaign is achieving net fusion energy gain (Qfus> 1), targeting a fusion power (Pfus) of 8–30 MW in deuterium–tritium (DT) plasma. For an optimally accurate and widely accepted demonstration of breakeven, the SPARC team is preparing for three independent methodologies to measure Pfus. The first method relies on neutron flux monitors and a neutron activation system, which together offer high time-resolution data using ionization chambers and dosimetry foils for absolute yield measurements. These are calibrated via an in situ DT neutron generator and detailed neutronics models. The second method employs collimated neutron diagnostics. A core-viewing magnetic-proton recoil spectrometer analyzes the neutron energy spectrum, while a poloidal profiler uses scintillator and diamond detectors to derive the DT neutron emissivity profile. Together, these diagnostics allow for a precise reconstruction of Pfus from core emissions. The third method calculates Pfus by volume-integrating the fusion reactivity using data from an array of kinetic profile diagnostics. Key inputs include temperature profiles from x-ray spectroscopy and electron–cyclotron emission measurements, plasma/electron density from Thomson-scattering, interferometry and edge-reflectometry, and fuel ion and impurity levels (Zeff) from optical and vacuum-UV spectroscopy. Neutral gas diagnostics and optical spectroscopy provide the critical fuel ion concentrations, which are also needed for corrections for the non-DT neutron contributions. By integrating these complementary techniques, SPARC ensures a robust and verified demonstration of Qfus > 1 in its first campaign.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessMeasurements for fusion power to demonstrate Q fus > 1 on SPARC (invited)
The SPARC tokamak’s primary goal in the first operational campaign is achieving net fusion energy gain (Qfus> 1), targeting a fusion power (Pfus) of 8–30 MW in deuterium–tritium (DT) plasma. For an optimally accurate and widely accepted demonstration of breakeven, the SPARC team is preparing for three independent methodologies to measure Pfus. The first method relies on neutron flux monitors and a neutron activation system, which together offer high time-resolution data using ionization chambers and dosimetry foils for absolute yield measurements. These are calibrated via an in situ DT neutron generator and detailed neutronics models. The second method employs collimated neutron diagnostics. A core-viewing magnetic-proton recoil spectrometer analyzes the neutron energy spectrum, while a poloidal profiler uses scintillator and diamond detectors to derive the DT neutron emissivity profile. Together, these diagnostics allow for a precise reconstruction of Pfus from core emissions. The third method calculates Pfus by volume-integrating the fusion reactivity using data from an array of kinetic profile diagnostics. Key inputs include temperature profiles from x-ray spectroscopy and electron–cyclotron emission measurements, plasma/electron density from Thomson-scattering, interferometry and edge-reflectometry, and fuel ion and impurity levels (Zeff) from optical and vacuum-UV spectroscopy. Neutral gas diagnostics and optical spectroscopy provide the critical fuel ion concentrations, which are also needed for corrections for the non-DT neutron contributions. By integrating these complementary techniques, SPARC ensures a robust and verified demonstration of Qfus > 1 in its first campaign.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
In-vessel design of a two-color heterodyne laser interferometer system for SPARC
This article covers the in-vessel design of the SPARC interferometry diagnostic system, highlighting unique aspects of the systems design and port plug integration in preparation for “day-1” plasma operations as a critical diagnostic for density feedback control. An early decision for the diagnostic was to deploy two lasers in the infrared wavelength spectrum, allowing the system to have a higher optical throughput. The optimization of the in-vessel geometry for the diagnostic follows a similar approach, focusing on de-risking possible damage to the plasma facing optical components by moving them further from the plasma with an orientation that provides a greater possibility for protective features to be added. The inclusion of in-vessel optical assemblies requires detailed design efforts of custom all-metal parts, designed to remain functional when subjected to harsh operational conditions, in many cases for the entire SPARC lifetime. The details presented here were included in the design to ensure that the assemblies can not only withstand a major electromagnetic disruption or thermal event but also maintain good stability through normal operations. The design also addresses more nuanced effects, such as the transient heat loading of the plasma facing mirrors. Through the utilization of modeling and design tools, these effects were brought into the design and simulation workflow, further reducing uncertainty as the system moves toward system commissioning.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
In-vessel design of a two-color heterodyne laser interferometer system for SPARC
This article covers the in-vessel design of the SPARC interferometry diagnostic system, highlighting unique aspects of the systems design and port plug integration in preparation for “day-1” plasma operations as a critical diagnostic for density feedback control. An early decision for the diagnostic was to deploy two lasers in the infrared wavelength spectrum, allowing the system to have a higher optical throughput. The optimization of the in-vessel geometry for the diagnostic follows a similar approach, focusing on de-risking possible damage to the plasma facing optical components by moving them further from the plasma with an orientation that provides a greater possibility for protective features to be added. The inclusion of in-vessel optical assemblies requires detailed design efforts of custom all-metal parts, designed to remain functional when subjected to harsh operational conditions, in many cases for the entire SPARC lifetime. The details presented here were included in the design to ensure that the assemblies can not only withstand a major electromagnetic disruption or thermal event but also maintain good stability through normal operations. The design also addresses more nuanced effects, such as the transient heat loading of the plasma facing mirrors. Through the utilization of modeling and design tools, these effects were brought into the design and simulation workflow, further reducing uncertainty as the system moves toward system commissioning.