Zhuoru Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhuoru Huang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hangming Xiong
Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication - Hao Wan
Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
1 shared publication - Jiaying Sun
Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication - Shimeng Mou
Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication - Weijie Yu
Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication - Wenwu Zhu
Evaluation Center of Medical Device of Zhejiang Province, Hangzhou 310000, China
1 shared publication
Latest Publications
- Open Access
- 25 December 2024
- Published by MDPI AG in Chemosensors
- Vol. 13 (1) , 3
Laser-Induced Graphene-Based Gas Sensor with PEDOT:PSS/Gold–Platinum Nanocomposites for Highly Sensitive Detection of Methane
Methane is a common intestinal gas that has been linked to a variety of gastrointestinal disorders. In this study, we prepared a LIG-based electrochemical sensor modified with PEDOT:PSS/Au-Pt nanocomposites for high-sensitivity methane detection. LIG’s high porosity, flexibility, and excellent electrical conductivity are beneficial for electrochemical detection. The PEDOT:PSS film is electrodeposited on the electrode surface to amplify the signal further. The synergistic effect of bimetallic nanocomposites can improve the electrochemical catalytic activity and increase the specific surface area and the advantages of active sites. The experimental results show that the LIG sensor has a wide linear detection range (2–500 ppm), a low detection limit (about 0.36 ppm), high sensitivity, and good repeatability. The sensor is easy to manufacture, is low-cost, operates at room temperature, has high sensitivity, has a low detection limit, and is expected to be used for methane breath detection in the future.
- 25 December 2024
- Published by MDPI AG in Chemosensors
- Vol. 13 (1) , 3
Open AccessLaser-Induced Graphene-Based Gas Sensor with PEDOT:PSS/Gold–Platinum Nanocomposites for Highly Sensitive Detection of Methane
Methane is a common intestinal gas that has been linked to a variety of gastrointestinal disorders. In this study, we prepared a LIG-based electrochemical sensor modified with PEDOT:PSS/Au-Pt nanocomposites for high-sensitivity methane detection. LIG’s high porosity, flexibility, and excellent electrical conductivity are beneficial for electrochemical detection. The PEDOT:PSS film is electrodeposited on the electrode surface to amplify the signal further. The synergistic effect of bimetallic nanocomposites can improve the electrochemical catalytic activity and increase the specific surface area and the advantages of active sites. The experimental results show that the LIG sensor has a wide linear detection range (2–500 ppm), a low detection limit (about 0.36 ppm), high sensitivity, and good repeatability. The sensor is easy to manufacture, is low-cost, operates at room temperature, has high sensitivity, has a low detection limit, and is expected to be used for methane breath detection in the future.