Peng Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peng Sun has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Mao Yang
4 shared publications- Mao Yang
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin 132012, China
4 shared publications - Qinghai Hao
Marketing Division of State Grid Gansu Electric Power Company, Lanzhou 730030, China
2 shared publications - Wencheng Li
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology Ministry of Education (Northeast Electric Power‐University) Jilin China
2 shared publications - Yi Chai
Economic and Technological Research Institute of State Grid Gansu Electric Power Company, Lanzhou 730030, China
2 shared publications - Yunfei Tian
Economic and Technological Research Institute of State Grid Gansu Electric Power Company, Lanzhou 730030, China
2 shared publications
Latest Publications
Conjugated Pyrazine Hydrazine Small Molecules Enable Heavy N‐Type Degenerate Doping of Inorganic Perovskites
Inorganic perovskites have attracted considerable attention in photovoltaic applications owing to their ideal tunable bandgaps and exceptional photothermal stability, rendering them a leading candidate for light‐absorbing materials in next‐generation perovskite solar cells. However, pure‐phase CsPbI 3 perovskite thin films suffer from crystalline disorder, high surface defect density, severe non‐radiative carrier recombination, and excessive open‐circuit voltage loss, collectively imposing severe limitations on both the power conversion efficiency ( PCE ) and environmental stability of the resulting optoelectronic devices. This work employs 2‐hydrazinopyrazine (Hdzpz) as a functional additive, leveraging the synergistic effect between its pyrazine‐based conjugated backbone and dual active nitrogen sites on the hydrazine group to rationally modulate the nucleation and growth kinetics, microstructural morphology, energy‐level alignment, interfacial properties, and hydrophobicity of CsPbI 3 perovskite thin films. This strategy effectively passivates undercoordinated lead defects and halide vacancies within the perovskite lattice. Meanwhile, CsPbI 3 is driven into a degenerate semiconductor state, yielding a heavily n‐type degenerately doped perovskite, thereby enhancing interfacial charge‐carrier transport efficiency. Ultimately, a PCE of 20.80% is achieved, accompanied by significantly improved photothermal and moisture stability.
Conjugated Pyrazine Hydrazine Small Molecules Enable Heavy N‐Type Degenerate Doping of Inorganic Perovskites
Inorganic perovskites have attracted considerable attention in photovoltaic applications owing to their ideal tunable bandgaps and exceptional photothermal stability, rendering them a leading candidate for light‐absorbing materials in next‐generation perovskite solar cells. However, pure‐phase CsPbI 3 perovskite thin films suffer from crystalline disorder, high surface defect density, severe non‐radiative carrier recombination, and excessive open‐circuit voltage loss, collectively imposing severe limitations on both the power conversion efficiency ( PCE ) and environmental stability of the resulting optoelectronic devices. This work employs 2‐hydrazinopyrazine (Hdzpz) as a functional additive, leveraging the synergistic effect between its pyrazine‐based conjugated backbone and dual active nitrogen sites on the hydrazine group to rationally modulate the nucleation and growth kinetics, microstructural morphology, energy‐level alignment, interfacial properties, and hydrophobicity of CsPbI 3 perovskite thin films. This strategy effectively passivates undercoordinated lead defects and halide vacancies within the perovskite lattice. Meanwhile, CsPbI 3 is driven into a degenerate semiconductor state, yielding a heavily n‐type degenerately doped perovskite, thereby enhancing interfacial charge‐carrier transport efficiency. Ultimately, a PCE of 20.80% is achieved, accompanied by significantly improved photothermal and moisture stability.
- Open Access
- 9 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4583
Optimal Configuration and Operation of Grid-Forming Electro-Hydrogen Energy Storage in New Power System Considering Power and Energy Balance
Aiming to address the problem of power and energy imbalance caused by a high proportion of new energy grid connections, the influence of fluctuation characteristics of both sides of the load on power and energy balance of new power systems is analyzed, and an evaluation system including core indicators such as power balance margin, peak regulation demand index and source–load power matching degree is proposed. Then, by analyzing the influence of the operation of electrolytic cell, hydrogen fuel cell and Grid-Forming energy storage equipment on the inertia level of a system, the inertia response control strategy of Grid-Forming electro-hydrogen energy storage (GFM-EHS) is proposed. Finally, considering frequency security constraints of the power system, virtual inertia and frequency support of the hydrogen energy system, an optimal configuration and scheduling method of new power system Grid-Forming hydrogen energy storage, considering that inertia support is proposed, which can provide a certain basis for improving new energy consumption capacity, ensuring the safe and stable operation of the new power grid and promoting green and low-carbon transformation of the energy structure.
- 9 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4583
Open AccessOptimal Configuration and Operation of Grid-Forming Electro-Hydrogen Energy Storage in New Power System Considering Power and Energy Balance
Aiming to address the problem of power and energy imbalance caused by a high proportion of new energy grid connections, the influence of fluctuation characteristics of both sides of the load on power and energy balance of new power systems is analyzed, and an evaluation system including core indicators such as power balance margin, peak regulation demand index and source–load power matching degree is proposed. Then, by analyzing the influence of the operation of electrolytic cell, hydrogen fuel cell and Grid-Forming energy storage equipment on the inertia level of a system, the inertia response control strategy of Grid-Forming electro-hydrogen energy storage (GFM-EHS) is proposed. Finally, considering frequency security constraints of the power system, virtual inertia and frequency support of the hydrogen energy system, an optimal configuration and scheduling method of new power system Grid-Forming hydrogen energy storage, considering that inertia support is proposed, which can provide a certain basis for improving new energy consumption capacity, ensuring the safe and stable operation of the new power grid and promoting green and low-carbon transformation of the energy structure.
- Open Access
Coordinated Optimization Strategy for Load Aggregator in Distribution Network Considering Demand Response and Peak Regulation Incentive
With the increasing proportion of flexible resources such as distributed generation, energy storage and demand response in new power systems, load aggregators, as an important subject connecting users and the market, face the challenges of complex load types, large differences in response capabilities, and high peaking costs. Therefore, this paper proposes a coordinated optimization strategy of load and electricity consumption considering aggregator load demand and peak load regulation incentive. Firstly, based on the operating characteristics of load equipment in multiple scenarios, the aggregator load is divided into three categories: energy storage type, elastic electrical equipment and inelastic electrical equipment, and the corresponding electricity cost model is established. Combined with utility theory and user subjective perception, a residential and industrial electricity comfort model is constructed. Secondly, a price-elasticity-based load potential assessment method is developed to quantify response envelopes under time-of-use tariffs, and a bi-level optimization model considering peak load regulation incentives is constructed. Next, in order to solve the bi-level non-convex optimization problem efficiently, a reinforcement learning solution framework based on a multi-agent deep deterministic policy gradient is proposed. The aggregator and user groups are modeled as collaborative agents respectively, and the global optimal strategy is realized by centralized training and decentralized execution. Finally, simulation results show that the proposed strategy can effectively guide the load from the peak period to the trough period, significantly improve the peak load shifting effect, improve the users’ electricity satisfaction, and reduce demand-side response cost.
Open AccessCoordinated Optimization Strategy for Load Aggregator in Distribution Network Considering Demand Response and Peak Regulation Incentive
With the increasing proportion of flexible resources such as distributed generation, energy storage and demand response in new power systems, load aggregators, as an important subject connecting users and the market, face the challenges of complex load types, large differences in response capabilities, and high peaking costs. Therefore, this paper proposes a coordinated optimization strategy of load and electricity consumption considering aggregator load demand and peak load regulation incentive. Firstly, based on the operating characteristics of load equipment in multiple scenarios, the aggregator load is divided into three categories: energy storage type, elastic electrical equipment and inelastic electrical equipment, and the corresponding electricity cost model is established. Combined with utility theory and user subjective perception, a residential and industrial electricity comfort model is constructed. Secondly, a price-elasticity-based load potential assessment method is developed to quantify response envelopes under time-of-use tariffs, and a bi-level optimization model considering peak load regulation incentives is constructed. Next, in order to solve the bi-level non-convex optimization problem efficiently, a reinforcement learning solution framework based on a multi-agent deep deterministic policy gradient is proposed. The aggregator and user groups are modeled as collaborative agents respectively, and the global optimal strategy is realized by centralized training and decentralized execution. Finally, simulation results show that the proposed strategy can effectively guide the load from the peak period to the trough period, significantly improve the peak load shifting effect, improve the users’ electricity satisfaction, and reduce demand-side response cost.
- Open Access
- 23 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (19) , 4381
Event-Triggered Coordinated Control of Frequency and Voltage for Multi-Energy Microgrid
With the increasing proportion of power electronic devices in multi-energy microgrid cluster systems, the inertia level of the system continues to decrease, posing severe challenges to the control of system frequency and voltage stability. To improve the frequency and voltage stability of multi-energy microgrid cluster systems, this paper proposes an event-triggered multi-energy microgrid control method to enhance voltage stability. Firstly, this paper analyzes the reactive power and voltage characteristics of multi-energy systems, and constructs stability control models for multi-energy microgrids considering gas network response and thermal network inertia. Aiming at studying the lagging response characteristic of the gas network, a coupling model including the dynamic characteristics of natural gas pressure regulating stations and gas pipelines is established to reveal the transmission mechanism of gas network pressure fluctuations on the output of distributed power sources. Secondly, focusing on the thermal network inertia, the buffering effect of thermal inertia on the power balance of the power grid is clarified by quantifying the heat storage capacity of the thermal pipelines. Then, for voltage control, an event-triggered mechanism based on model prediction is established to adaptively adjust the update timing of control commands, achieving rapid correction of voltage deviations. Finally, for frequency control, a multi-time-scale response framework is constructed, utilizing the millisecond-level response of energy storage systems, the medium-term support of gas turbines, and the long-term buffering of thermal network inertia to form a frequency stability system covering the entire disturbance cycle.
- 23 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (19) , 4381
Open AccessEvent-Triggered Coordinated Control of Frequency and Voltage for Multi-Energy Microgrid
With the increasing proportion of power electronic devices in multi-energy microgrid cluster systems, the inertia level of the system continues to decrease, posing severe challenges to the control of system frequency and voltage stability. To improve the frequency and voltage stability of multi-energy microgrid cluster systems, this paper proposes an event-triggered multi-energy microgrid control method to enhance voltage stability. Firstly, this paper analyzes the reactive power and voltage characteristics of multi-energy systems, and constructs stability control models for multi-energy microgrids considering gas network response and thermal network inertia. Aiming at studying the lagging response characteristic of the gas network, a coupling model including the dynamic characteristics of natural gas pressure regulating stations and gas pipelines is established to reveal the transmission mechanism of gas network pressure fluctuations on the output of distributed power sources. Secondly, focusing on the thermal network inertia, the buffering effect of thermal inertia on the power balance of the power grid is clarified by quantifying the heat storage capacity of the thermal pipelines. Then, for voltage control, an event-triggered mechanism based on model prediction is established to adaptively adjust the update timing of control commands, achieving rapid correction of voltage deviations. Finally, for frequency control, a multi-time-scale response framework is constructed, utilizing the millisecond-level response of energy storage systems, the medium-term support of gas turbines, and the long-term buffering of thermal network inertia to form a frequency stability system covering the entire disturbance cycle.
- Open Access
- 28 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3335
Cluster Optimization of an Integrated Energy System for a Park Based on Demand Response
To address the issues of insufficient operational flexibility and low energy coordination efficiency of the integrated energy system in the park under the integration of large-scale distributed renewable energy, it is essential to carry out research on multi-energy complementary cluster division and optimal operation to improve regional energy utilization efficiency. Focusing on the multi-energy coupling system of electric heating and gas in the park, this paper proposes a method of electric heating and gas collaborative cluster division that considers the demand response potential. First, the multi-energy coupling topology model of the integrated energy system in the park is constructed, and the demand response potential index of each sub-region is quantitatively evaluated. A modularity evaluation function integrating multi-energy coupling characteristics is proposed. Based on the improved Louvain algorithm, the dynamic cluster division of the electric heating and gas system in the park is realized. On this basis, a cluster-level optimization operation model considering demand response resource integration is established, and optimal scheduling is carried out with the goal of minimizing operating costs. Finally, an industrial park in Northeast China is used as an actual case for verification. The results show that the proposed cluster division method can divide the park into four electricity, heating, and gas integrated energy clusters with clear characteristics and close coupling. After the integration of demand response resources, the overall operating cost of the system is reduced and the new energy consumption rate is increased. This verifies the effectiveness and superiority of the proposed method and provides technical support for the optimal operation of the integrated energy system in the park.
- 28 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3335
Open AccessCluster Optimization of an Integrated Energy System for a Park Based on Demand Response
To address the issues of insufficient operational flexibility and low energy coordination efficiency of the integrated energy system in the park under the integration of large-scale distributed renewable energy, it is essential to carry out research on multi-energy complementary cluster division and optimal operation to improve regional energy utilization efficiency. Focusing on the multi-energy coupling system of electric heating and gas in the park, this paper proposes a method of electric heating and gas collaborative cluster division that considers the demand response potential. First, the multi-energy coupling topology model of the integrated energy system in the park is constructed, and the demand response potential index of each sub-region is quantitatively evaluated. A modularity evaluation function integrating multi-energy coupling characteristics is proposed. Based on the improved Louvain algorithm, the dynamic cluster division of the electric heating and gas system in the park is realized. On this basis, a cluster-level optimization operation model considering demand response resource integration is established, and optimal scheduling is carried out with the goal of minimizing operating costs. Finally, an industrial park in Northeast China is used as an actual case for verification. The results show that the proposed cluster division method can divide the park into four electricity, heating, and gas integrated energy clusters with clear characteristics and close coupling. After the integration of demand response resources, the overall operating cost of the system is reduced and the new energy consumption rate is increased. This verifies the effectiveness and superiority of the proposed method and provides technical support for the optimal operation of the integrated energy system in the park.
- Open Access
- 24 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3272
Multi-Time-Scale Distributionally Robust Dispatch of Hydrogen-Based Integrated Energy System Based on Wasserstein Distance
To address the coordinated economic, low-carbon, and robust operation problem caused by source–load forecast uncertainty in hydrogen-based integrated energy systems, this paper proposes a multi-time-scale distributionally robust scheduling framework based on the Wasserstein distance. First, a hydrogen-based polygeneration model is established by coordinating an electrolyzer, a hydrogen storage tank, a methanation reactor, and a hydrogen fuel cell. A dual-heat-source organic Rankine cycle is further introduced to recover waste heat from the microturbine and hydrogen fuel cell, thereby strengthening the coupling among electricity, heat, gas, and hydrogen. Second, a source–load coordination mechanism is developed by integrating pre-contracted stepped demand response with output-based carbon allocation and stepped carbon trading. On this basis, a two-stage day-ahead Wasserstein distributionally robust optimization model is formulated to account for joint wind-power and multi-energy-load forecast errors, while 15 min intraday and 5 min real-time rolling optimization are used to correct scheduling deviations. Finally, mechanism-ablation, physical-feasibility, uncertainty-handling, and parameter-sensitivity studies are conducted. The results show that M-5 reduces the total operating cost and net carbon emissions by 13.66% and 23.87%, respectively, relative to M-1, while reducing the wind-curtailment rate from 16.43% to zero. Among the tested uncertainty-handling methods, W-DRO achieves the lowest held-out total cost with a 3% shortfall rate, and the lowest-cost range is obtained for Wasserstein radii of 0.02–0.05. These results demonstrate that the proposed framework provides a favorable case-specific trade-off among economic performance, carbon reduction, renewable-energy accommodation, and operational robustness.
- 24 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (15) , 3272
Open AccessMulti-Time-Scale Distributionally Robust Dispatch of Hydrogen-Based Integrated Energy System Based on Wasserstein Distance
To address the coordinated economic, low-carbon, and robust operation problem caused by source–load forecast uncertainty in hydrogen-based integrated energy systems, this paper proposes a multi-time-scale distributionally robust scheduling framework based on the Wasserstein distance. First, a hydrogen-based polygeneration model is established by coordinating an electrolyzer, a hydrogen storage tank, a methanation reactor, and a hydrogen fuel cell. A dual-heat-source organic Rankine cycle is further introduced to recover waste heat from the microturbine and hydrogen fuel cell, thereby strengthening the coupling among electricity, heat, gas, and hydrogen. Second, a source–load coordination mechanism is developed by integrating pre-contracted stepped demand response with output-based carbon allocation and stepped carbon trading. On this basis, a two-stage day-ahead Wasserstein distributionally robust optimization model is formulated to account for joint wind-power and multi-energy-load forecast errors, while 15 min intraday and 5 min real-time rolling optimization are used to correct scheduling deviations. Finally, mechanism-ablation, physical-feasibility, uncertainty-handling, and parameter-sensitivity studies are conducted. The results show that M-5 reduces the total operating cost and net carbon emissions by 13.66% and 23.87%, respectively, relative to M-1, while reducing the wind-curtailment rate from 16.43% to zero. Among the tested uncertainty-handling methods, W-DRO achieves the lowest held-out total cost with a 3% shortfall rate, and the lowest-cost range is obtained for Wasserstein radii of 0.02–0.05. These results demonstrate that the proposed framework provides a favorable case-specific trade-off among economic performance, carbon reduction, renewable-energy accommodation, and operational robustness.
- Open Access
- 31 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2371
Optimal Scheduling Model for Renewable Energy Electrothermal Coupling System Considering Market Clearing Mechanism of Thermal Storage Power Plant
In the context of spot electricity markets, the fluctuation characteristics of node electricity prices play a crucial role in guiding the operational strategies of thermal power plants. However, constrained by the inelastic demand for heat, the strong coupling between electricity and heat in combined heat and power (CHP) units limits their ability to regulate electricity generation. These conditions present considerable difficulties for the economic feasibility and carbon reduction performance of these units, especially with high levels of renewable energy integration and during intensive peak-load shaving operations. In response to these challenges, this paper introduces an optimized dispatch method for renewable energy–electricity–heat coupled systems in thermal power plants with thermal storage, which incorporates the coordinated clearing of nodal electricity prices. First, a spot market clearing mechanism is established based on a DC optimal power flow model, and node electricity price signals reflecting network congestion characteristics are endogenously generated through the Lagrange multiplier of the node power balance constraint. Next, by introducing node injection power as a coupling variable between the grid clearing model and the CHP plant scheduling model, a co-optimization framework with bidirectional feedback between electricity prices and unit output is constructed. In conclusion, the integration of node electricity prices, deep peak-shaving costs, and carbon emission costs into a unified optimization objective leads to the development of a scheduling model for the renewable energy–electricity–heat coupled system, which includes CHP units, thermal storage, and grid interactions. The simulation results show that the proposed method can effectively improve the performance of the electric–thermal coupling system under the condition of a high proportion of renewable energy access. Under the typical daily load and new energy output conditions, the total cost of the system is reduced by about 9.7%, the carbon emission is reduced by about 18.3%, and the peak shaving capacity is increased from 25 MW to 58 MW, thus enhancing the flexible scheduling ability and market adaptability of the heat storage thermal power plant.
- 31 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2371
Open AccessOptimal Scheduling Model for Renewable Energy Electrothermal Coupling System Considering Market Clearing Mechanism of Thermal Storage Power Plant
In the context of spot electricity markets, the fluctuation characteristics of node electricity prices play a crucial role in guiding the operational strategies of thermal power plants. However, constrained by the inelastic demand for heat, the strong coupling between electricity and heat in combined heat and power (CHP) units limits their ability to regulate electricity generation. These conditions present considerable difficulties for the economic feasibility and carbon reduction performance of these units, especially with high levels of renewable energy integration and during intensive peak-load shaving operations. In response to these challenges, this paper introduces an optimized dispatch method for renewable energy–electricity–heat coupled systems in thermal power plants with thermal storage, which incorporates the coordinated clearing of nodal electricity prices. First, a spot market clearing mechanism is established based on a DC optimal power flow model, and node electricity price signals reflecting network congestion characteristics are endogenously generated through the Lagrange multiplier of the node power balance constraint. Next, by introducing node injection power as a coupling variable between the grid clearing model and the CHP plant scheduling model, a co-optimization framework with bidirectional feedback between electricity prices and unit output is constructed. In conclusion, the integration of node electricity prices, deep peak-shaving costs, and carbon emission costs into a unified optimization objective leads to the development of a scheduling model for the renewable energy–electricity–heat coupled system, which includes CHP units, thermal storage, and grid interactions. The simulation results show that the proposed method can effectively improve the performance of the electric–thermal coupling system under the condition of a high proportion of renewable energy access. Under the typical daily load and new energy output conditions, the total cost of the system is reduced by about 9.7%, the carbon emission is reduced by about 18.3%, and the peak shaving capacity is increased from 25 MW to 58 MW, thus enhancing the flexible scheduling ability and market adaptability of the heat storage thermal power plant.
- Open Access
- 11 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2038
Resilience Improvement Method of Distribution Network Based on Optimal Control of FCEV
Aiming at the power fluctuation of the distribution network caused by the fluctuation of renewable energy output in the sending-end power grid. In this paper, a coordinated optimization method of mobile energy storage for distribution networks with a high proportion of renewable energy sending end systems is proposed to improve the energy support of the sending end distribution network and improve the resilience of the distribution network. Firstly, based on the mobile characteristics of mobile energy storage, a space-time transfer and charge-discharge model of mobile energy storage based on the traffic network is established. Secondly, by analyzing the network structure of the distribution network of the sending end system. The mobile energy storage scheduling mode is adopted, and the mobile energy storage support model of the sending end system is established with the minimum cost of load shedding and the minimum cost of mobile energy storage scheduling. Then, the power balance of the sending end system and the power balance of the distribution network are respectively targeted. The power balance equation of the sending end system based on the balance constraint of charging and discharging of mobile energy storage is established. Finally, a distribution network in the sending-end system is taken as an example for simulation. It is verified that the strategy proposed in this paper can effectively improve the stability of the sending power of the sending end system and maintain the balance of the distribution network.
- 11 May 2026
- Published by MDPI AG in Electronics
- Vol. 15 (10) , 2038
Open AccessResilience Improvement Method of Distribution Network Based on Optimal Control of FCEV
Aiming at the power fluctuation of the distribution network caused by the fluctuation of renewable energy output in the sending-end power grid. In this paper, a coordinated optimization method of mobile energy storage for distribution networks with a high proportion of renewable energy sending end systems is proposed to improve the energy support of the sending end distribution network and improve the resilience of the distribution network. Firstly, based on the mobile characteristics of mobile energy storage, a space-time transfer and charge-discharge model of mobile energy storage based on the traffic network is established. Secondly, by analyzing the network structure of the distribution network of the sending end system. The mobile energy storage scheduling mode is adopted, and the mobile energy storage support model of the sending end system is established with the minimum cost of load shedding and the minimum cost of mobile energy storage scheduling. Then, the power balance of the sending end system and the power balance of the distribution network are respectively targeted. The power balance equation of the sending end system based on the balance constraint of charging and discharging of mobile energy storage is established. Finally, a distribution network in the sending-end system is taken as an example for simulation. It is verified that the strategy proposed in this paper can effectively improve the stability of the sending power of the sending end system and maintain the balance of the distribution network.
- Open Access
- 30 April 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 259
Load forecasting and energy storage optimization control for distribution networks with high distributed photovoltaic penetration
- 30 April 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 259
Open AccessLoad forecasting and energy storage optimization control for distribution networks with high distributed photovoltaic penetration