Heidi Hayes
Research Subjects
Research Interests
Heidi Hayes has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- John H. Zimmerman
Watershed and Ecosystem Characterization Division, Center for Environmental Measurement & Modeling (CEMM), Office of Research and Development (ORD), U.S. Environmental Protection Agency (EPA), 109 TW Alexander Dr., Research Triangle Park, NC 27711, USA
2 shared publications Nicola Watson
Eurofins Air Toxics LLC, Folsom, CA 95630, USA
2 shared publicationsAlan Owens
Shimadzu Scientific Instruments, Columbia, MD 21046, USA
1 shared publicationAlan Williams
U.S. Environmental Protection Agency, Office of Research and Development Center for Environmental Measurement and Modeling, Watershed and Ecosystem Characterization Division, Research Triangle Park, NC, USA
1 shared publication- Benjamin Kim
SGS North America Inc., EHS Operations, Dayton, NJ 08810, USA
1 shared publication Bharat Chandramouli
SGS AXYS Analytical Services Ltd., Sidney, BC V8L 5×2, Canada
1 shared publication
Latest Publications
- 21 January 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1769, 466725
Measuring fluorotelomer alcohols by thermal desorption-gas chromatography-tandem mass spectrometry: Interlaboratory study results
- 21 January 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1769, 466725
Measuring fluorotelomer alcohols by thermal desorption-gas chromatography-tandem mass spectrometry: Interlaboratory study results
- Open Access
- 31 July 2025
- Published by MDPI AG in Environments
- Vol. 12 (8) , 267
Long-Term Performance of Passive Volatile Organic Compounds (VOCs) Samplers for Indoor Air
The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive samplers (e.g., Radiello® 130 passive samplers with white diffusive bodies) over exposure periods ranging from 1 week to 1 year in a test house with known vapor intrusion (VI). Chloroform %Bias values exceeded the ±30% acceptance criterion after 4 weeks exposure. Benzene, hexane, and trichloroethylene (TCE) concentrations were within the acceptance criterion for up to three months. Toluene and tetrachloroethylene (PCE), the two least volatile compounds, demonstrated uniform uptake rates over one year. In the second phase of this study, testing of the longer exposure times of 6 months and 1 year were evaluated with three additional passive samplers: Waterloo Membrane SamplerTM (WMSTM), SKC 575 with secondary diffusive cover, and Radiello® 130 passive samplers with yellow diffusive bodies. The SKC 575 and Radiello® 130 passive samplers produced acceptable results (%Bias ≤ 30%) over the 6-month exposure period, while the WMSTM sampler results favored petroleum hydrocarbon more than chlorinated solvent uptake. After the 1-year exposure period, the passive sampler performances were acceptable under specific conditions of this study. The results suggest that all three samplers can produce acceptable results over exposure time periods beyond 30 days and up to a year for some compounds.
- 31 July 2025
- Published by MDPI AG in Environments
- Vol. 12 (8) , 267
Open AccessLong-Term Performance of Passive Volatile Organic Compounds (VOCs) Samplers for Indoor Air
The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive samplers (e.g., Radiello® 130 passive samplers with white diffusive bodies) over exposure periods ranging from 1 week to 1 year in a test house with known vapor intrusion (VI). Chloroform %Bias values exceeded the ±30% acceptance criterion after 4 weeks exposure. Benzene, hexane, and trichloroethylene (TCE) concentrations were within the acceptance criterion for up to three months. Toluene and tetrachloroethylene (PCE), the two least volatile compounds, demonstrated uniform uptake rates over one year. In the second phase of this study, testing of the longer exposure times of 6 months and 1 year were evaluated with three additional passive samplers: Waterloo Membrane SamplerTM (WMSTM), SKC 575 with secondary diffusive cover, and Radiello® 130 passive samplers with yellow diffusive bodies. The SKC 575 and Radiello® 130 passive samplers produced acceptable results (%Bias ≤ 30%) over the 6-month exposure period, while the WMSTM sampler results favored petroleum hydrocarbon more than chlorinated solvent uptake. After the 1-year exposure period, the passive sampler performances were acceptable under specific conditions of this study. The results suggest that all three samplers can produce acceptable results over exposure time periods beyond 30 days and up to a year for some compounds.
- Open Access
- 20 November 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Atmospheres
- Vol. 5 (1) , 94-109
Laboratory development and validation of vapor phase PFAS methods for soil gas, sewer gas, and indoor air
A thermal desorption GC-tandem MS method was developed to measure vapor-phase PFAS and their potential migration into indoor air.
- 20 November 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Atmospheres
- Vol. 5 (1) , 94-109
Open AccessLaboratory development and validation of vapor phase PFAS methods for soil gas, sewer gas, and indoor air
A thermal desorption GC-tandem MS method was developed to measure vapor-phase PFAS and their potential migration into indoor air.