Guillem Muntané-Carol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guillem Muntané-Carol has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Josep Rodés-Cabau
Laval University
5 shared publications - Luis Nombela-Franco
Cardiovascular Institute, Hospital Clínico San Carlos, IdISSC, Madrid, Spain
4 shared publications - Gabriela Veiga-Fernandez
University Hospital Marqués de Valdecilla
3 shared publications Ander Regueiro
2 shared publications- Ander Regueiro
Cardiovascular Institute, Hospital Clinic, Institut D’investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), 08036 Barcelona, Spain
2 shared publications - David del Val
Cardiology Department, Hospital de La Princesa, Madrid, Spain (D.V., F.A.).
2 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (10)
Temporary Active Fixation Leads in Transcatheter Aortic Valve Replacement Patients With Baseline Right Bundle Branch Block
- 26 August 2026
- Published by Elsevier in Structural Heart
- Vol. 10 (10)
Open AccessTemporary Active Fixation Leads in Transcatheter Aortic Valve Replacement Patients With Baseline Right Bundle Branch Block
- 1 May 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (5) , e015991
Cardiac Structural Complications Following TAVR
BACKGROUND: Cardiac structural complications (CSCs) have been recently established by the Valve Academic Research Consortium 3 consensus as a combined end point including multiple life-threatening periprocedural events following transcatheter aortic valve replacement. The objective was to assess the incidence, timing, management, and clinical impact of CSCs in the contemporary transcatheter aortic valve replacement era. METHODS: Multicenter study including consecutive patients undergoing transcatheter aortic valve replacement in 18 European and Canadian centers from 2014 to 2024. According to the Valve Academic Research Consortium 3 criteria, CSCs included cardiac structure perforation, injury or compromise, new pericardial effusion, and coronary obstruction. Data was collected in a dedicated database, and patients were followed at 30 days, 1 year, and yearly thereafter. RESULTS: Among a total of 10 541 patients, CSCs occurred in 221 (2.1%), with 126 (1.2%) patients exhibiting >1 CSC: 146 (1.4%) cardiac structure compromise events (annular rupture: 41.1%, left ventricular perforation: 26.0%; right ventricular perforation: 24.0%, other injuries: 8.9%), 150 (1.4%) new pericardial effusions, and 59 (0.6%) coronary obstructions. Up to 75.6% of CSCs occurred intraprocedurally, and 61 (27.6%) patients had conversion to open heart surgery. The incidence of CSCs remained similar throughout the study period (from 1.3% to 3.2%, median annual rate of 2.3%). Thirty-day mortality was 35.3% (52.5% among patients requiring conversion to surgery), with annular rupture associated with the highest (41.0%) mortality rate. CONCLUSIONS: About 2% of contemporary transcatheter aortic valve replacement recipients presented CSCs, which did not decrease over time, required conversion to surgery in more than one-fourth of cases, and were associated with very high periprocedural mortality rates. Further research is needed regarding potential preventive strategies and optimal surgical bailout management.
- 1 May 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (5) , e015991
Cardiac Structural Complications Following TAVR
BACKGROUND: Cardiac structural complications (CSCs) have been recently established by the Valve Academic Research Consortium 3 consensus as a combined end point including multiple life-threatening periprocedural events following transcatheter aortic valve replacement. The objective was to assess the incidence, timing, management, and clinical impact of CSCs in the contemporary transcatheter aortic valve replacement era. METHODS: Multicenter study including consecutive patients undergoing transcatheter aortic valve replacement in 18 European and Canadian centers from 2014 to 2024. According to the Valve Academic Research Consortium 3 criteria, CSCs included cardiac structure perforation, injury or compromise, new pericardial effusion, and coronary obstruction. Data was collected in a dedicated database, and patients were followed at 30 days, 1 year, and yearly thereafter. RESULTS: Among a total of 10 541 patients, CSCs occurred in 221 (2.1%), with 126 (1.2%) patients exhibiting >1 CSC: 146 (1.4%) cardiac structure compromise events (annular rupture: 41.1%, left ventricular perforation: 26.0%; right ventricular perforation: 24.0%, other injuries: 8.9%), 150 (1.4%) new pericardial effusions, and 59 (0.6%) coronary obstructions. Up to 75.6% of CSCs occurred intraprocedurally, and 61 (27.6%) patients had conversion to open heart surgery. The incidence of CSCs remained similar throughout the study period (from 1.3% to 3.2%, median annual rate of 2.3%). Thirty-day mortality was 35.3% (52.5% among patients requiring conversion to surgery), with annular rupture associated with the highest (41.0%) mortality rate. CONCLUSIONS: About 2% of contemporary transcatheter aortic valve replacement recipients presented CSCs, which did not decrease over time, required conversion to surgery in more than one-fourth of cases, and were associated with very high periprocedural mortality rates. Further research is needed regarding potential preventive strategies and optimal surgical bailout management.
- 1 February 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (2) , e015579
Risk of Delayed Atrioventricular Block in TAVR Recipients With Preexisting Right Bundle Branch Block
- 1 February 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (2) , e015579
Risk of Delayed Atrioventricular Block in TAVR Recipients With Preexisting Right Bundle Branch Block
- 18 December 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 105 (3) , 599-601
Immediate Percutaneous Treatment of Aortic Root Rupture During Transcatheter Aortic Valve Implantation
This case shows the combination of two percutaneous techniques to treat an aortic root rupture during transcatheter aortic valve implantation. The patient was discharged at home and no cardiovascular events occurred at 12 months of follow up.
- 18 December 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 105 (3) , 599-601
Immediate Percutaneous Treatment of Aortic Root Rupture During Transcatheter Aortic Valve Implantation
This case shows the combination of two percutaneous techniques to treat an aortic root rupture during transcatheter aortic valve implantation. The patient was discharged at home and no cardiovascular events occurred at 12 months of follow up.
- Open Access
- 24 December 2023
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 40 (7) , 1226-1233
In-hospital Outcomes of Rotational Atherectomy in ST-Elevation Myocardial Infarction: Results From the Multicentre ROTA-STEMI Network
- 24 December 2023
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 40 (7) , 1226-1233
Open AccessIn-hospital Outcomes of Rotational Atherectomy in ST-Elevation Myocardial Infarction: Results From the Multicentre ROTA-STEMI Network
- Open Access
- 1 September 2021
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 14 (9) , e010641
Horizontal Aorta in Transcatheter Self-Expanding Valves: Insights From the HORSE International Multicentre Registry
Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.
- 1 September 2021
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 14 (9) , e010641
Open AccessHorizontal Aorta in Transcatheter Self-Expanding Valves: Insights From the HORSE International Multicentre Registry
Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.
- 1 May 2021
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 14 (9) , 992-994
Managing Conduction Disturbances After TAVR
- 1 May 2021
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 14 (9) , 992-994
Managing Conduction Disturbances After TAVR
- 1 August 2020
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 13 (15) , 1763-1773
Prolonged Continuous Electrocardiographic Monitoring Prior to Transcatheter Aortic Valve Replacement
- 1 August 2020
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 13 (15) , 1763-1773
Prolonged Continuous Electrocardiographic Monitoring Prior to Transcatheter Aortic Valve Replacement