Sameh Salem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sameh Salem has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mekhaeel Shehata Fakhry Mekhaeel
RUDN University
9 shared publications - Andrei Dmitrievich Protasov
Department of Operative Surgery and Clinical Anatomy named after I.D. Kirpatovsky, Medical Institute Peoples' Friendship University of Russia named after Patrice Lumumba (RUDN University) Moscow Russia
7 shared publications - Andrey V. Protasov
RUDN University
2 shared publications - Kambiz Ebrahimi
Department of Oral and Maxillofacial Surgery and Surgical Dentistry, Medical Institute, Peoples’ Friendship University of Russia, Named after Patrice Lumumba (RUDN University), Moscow, Russian Federation
2 shared publications - Tahoura Talebidelooei
Department of Oral and Maxillofacial Surgery and Surgical Dentistry, Medical Institute, Peoples’ Friendship University of Russia, Named after Patrice Lumumba (RUDN University), Moscow, Russian Federation
2 shared publications - Watban Khalid Al Tekreeti2 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Wiley in World Journal of Otorhinolaryngology - Head and Neck Surgery
Prognostic Value of Initial CT Imaging for Surgical Planning and Outcomes in Panfacial Fractures: A Systematic Review and Meta‐Analysis
Objective: To evaluate the reported prognostic value of initial computed tomography (CT) imaging for surgical planning and postoperative outcomes in panfacial fractures, and to determine whether CT‐derived variables have been consistently linked to clinically relevant outcomes. Data Sources: PubMed, MEDLINE, Embase, Cochrane Library, CINAHL, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform were searched from database inception to January 1, 2026. Eligible studies were restricted to publications from January 2015 onward. Methods: Studies were eligible if they included patients with panfacial fractures or separately extractable panfacial fracture subgroups, reported CT or imaging‐based assessment for diagnosis or surgical planning, and provided extractable postoperative or surgical‐management outcomes. Study characteristics, CT‐related variables, surgical‐planning data, and postoperative outcomes were extracted. Random‐effects meta‐analysis of single proportions was performed for infection, malocclusion, revision or secondary surgery, and enophthalmos. CT‐derived prognostic evidence was synthesized narratively according to whether imaging variables were directly or indirectly linked to outcomes. Results: Sixteen studies involving 1811 patients were included. Pooled postoperative complication prevalences were 11% for infection (95% CI, 0%–90%), 10% for malocclusion (95% CI, 5%–19%), 2% for revision or secondary surgery (95% CI, 2%–4%), and 5% for enophthalmos (95% CI, 1%–21%). CT, multiplanar imaging, or three‐dimensional reconstruction was frequently reported for fracture characterization and operative planning. However, standardized CT‐derived prognostic variables were inconsistently reported, and few studies directly linked initial imaging findings to postoperative outcomes. Conclusion: Initial CT imaging is essential for assessment and surgical planning in panfacial fractures. Current evidence provides pooled postoperative benchmarks but remains insufficient to establish robust CT‐based prognostic prediction. Standardized CT reporting, fracture‐severity classification, and outcome assessment are needed to clarify whether initial imaging findings can predict surgical complexity and long‐term outcomes.
- 29 September 2026
- Published by Wiley in World Journal of Otorhinolaryngology - Head and Neck Surgery
Open AccessPrognostic Value of Initial CT Imaging for Surgical Planning and Outcomes in Panfacial Fractures: A Systematic Review and Meta‐Analysis
Objective: To evaluate the reported prognostic value of initial computed tomography (CT) imaging for surgical planning and postoperative outcomes in panfacial fractures, and to determine whether CT‐derived variables have been consistently linked to clinically relevant outcomes. Data Sources: PubMed, MEDLINE, Embase, Cochrane Library, CINAHL, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform were searched from database inception to January 1, 2026. Eligible studies were restricted to publications from January 2015 onward. Methods: Studies were eligible if they included patients with panfacial fractures or separately extractable panfacial fracture subgroups, reported CT or imaging‐based assessment for diagnosis or surgical planning, and provided extractable postoperative or surgical‐management outcomes. Study characteristics, CT‐related variables, surgical‐planning data, and postoperative outcomes were extracted. Random‐effects meta‐analysis of single proportions was performed for infection, malocclusion, revision or secondary surgery, and enophthalmos. CT‐derived prognostic evidence was synthesized narratively according to whether imaging variables were directly or indirectly linked to outcomes. Results: Sixteen studies involving 1811 patients were included. Pooled postoperative complication prevalences were 11% for infection (95% CI, 0%–90%), 10% for malocclusion (95% CI, 5%–19%), 2% for revision or secondary surgery (95% CI, 2%–4%), and 5% for enophthalmos (95% CI, 1%–21%). CT, multiplanar imaging, or three‐dimensional reconstruction was frequently reported for fracture characterization and operative planning. However, standardized CT‐derived prognostic variables were inconsistently reported, and few studies directly linked initial imaging findings to postoperative outcomes. Conclusion: Initial CT imaging is essential for assessment and surgical planning in panfacial fractures. Current evidence provides pooled postoperative benchmarks but remains insufficient to establish robust CT‐based prognostic prediction. Standardized CT reporting, fracture‐severity classification, and outcome assessment are needed to clarify whether initial imaging findings can predict surgical complexity and long‐term outcomes.
- Open Access
- 15 March 2026
- Published by Peoples' Friendship University of Russia in RUDN Journal of Medicine
- Vol. 30 (1) , 55-65
Employing seamless mesh implants during Lichtenstein hernia repair with the use of insights enabled by artificial intelligence
Relevance. Globally, there are now 32.53 million hernia cases, up from about 23.92 million during the previous 3 decades. Many authors lack statistical knowledge, which could jeopardize healthcare. The aim was to use artificial intelligence as a statistical technique to assess the potential effects of AdhesixTM self-gripping mesh implants, HertraTM mesh implants, and LintexTM glue-fixed mesh implants on the outcomes of inguinal hernia patients who underwent open inguinal hernia repair in Lichtenstein. Materials and Methods. We performed 120 Liechtenstein-compliant inguinal hernia repair procedures on three evenly split patient groups (n = 40) using AdhesixTM, HertraTM, and LintexTM mesh implants. The parameters for comparison were the time-frame of the procedure, hospital-stays, challenges afterwards surgery, and issues that arose during the brief follow-up. Results and Discussion. Patients of the first group were hospitalized for shorter periods of time than those in the second and third groups (group A-4.9 bed /day, group B-4.9.5 bed /day, and group C-4.95 bed /day), with no statistically significant differences. Patients in the first group experience a significantly shorter procedure time, followed by those in the second and third groups (27.8 min, 31.4 min, and 38.9 min respectively). Unlike the third group, which included 3 patients with postoperative discomfort and 1 with postoperative seroma formation, the first and second groups’ postoperative hospitalization stays were free of complications. In contrast to the third group’s 2 patients who experienced mesh migration and hernia recurrence, the first and second groups’ patients experienced no complications during the short-term follow-up. Conclusion. Compared to LintexTM mesh implants, the operative times using AdhesixTM and HertraTM are significantly shorter with no post-operative complications or hernia recurrence.
- 15 March 2026
- Published by Peoples' Friendship University of Russia in RUDN Journal of Medicine
- Vol. 30 (1) , 55-65
Open AccessEmploying seamless mesh implants during Lichtenstein hernia repair with the use of insights enabled by artificial intelligence
Relevance. Globally, there are now 32.53 million hernia cases, up from about 23.92 million during the previous 3 decades. Many authors lack statistical knowledge, which could jeopardize healthcare. The aim was to use artificial intelligence as a statistical technique to assess the potential effects of AdhesixTM self-gripping mesh implants, HertraTM mesh implants, and LintexTM glue-fixed mesh implants on the outcomes of inguinal hernia patients who underwent open inguinal hernia repair in Lichtenstein. Materials and Methods. We performed 120 Liechtenstein-compliant inguinal hernia repair procedures on three evenly split patient groups (n = 40) using AdhesixTM, HertraTM, and LintexTM mesh implants. The parameters for comparison were the time-frame of the procedure, hospital-stays, challenges afterwards surgery, and issues that arose during the brief follow-up. Results and Discussion. Patients of the first group were hospitalized for shorter periods of time than those in the second and third groups (group A-4.9 bed /day, group B-4.9.5 bed /day, and group C-4.95 bed /day), with no statistically significant differences. Patients in the first group experience a significantly shorter procedure time, followed by those in the second and third groups (27.8 min, 31.4 min, and 38.9 min respectively). Unlike the third group, which included 3 patients with postoperative discomfort and 1 with postoperative seroma formation, the first and second groups’ postoperative hospitalization stays were free of complications. In contrast to the third group’s 2 patients who experienced mesh migration and hernia recurrence, the first and second groups’ patients experienced no complications during the short-term follow-up. Conclusion. Compared to LintexTM mesh implants, the operative times using AdhesixTM and HertraTM are significantly shorter with no post-operative complications or hernia recurrence.
- Open Access
- 27 February 2026
- Published by Elsevier in Surgery Case Reports
- Vol. 8
Multidisciplinary management of complex craniofacial animal bites in children: A case series and review of principles
- 27 February 2026
- Published by Elsevier in Surgery Case Reports
- Vol. 8
Open AccessMultidisciplinary management of complex craniofacial animal bites in children: A case series and review of principles
- 27 April 2025
- Published by European Scientific Society in Archiv Euromedica
- Vol. 15 (2)
AI-Based Evaluation of Polypropylene and Polyester Meshes in Lichtenstein Hernia Repair
Aims: This study aimed to evaluate the clinical outcomes of using polypropylene and polyester mesh implants in inguinal hernia repair via the Lichtenstein technique, employing artificial intelligence and machine learning tools for statistical analysis. Methods: A total of 58 patients with primary unilateral inguinal hernias were operated on using the Lichtenstein technique over a three-year period. They were divided into two groups: Group A (38 patients, mean age 58.05 years; 34 males, 4 females) received polypropylene meshes, while Group B (20 patients, mean age 50.05 years; all males) received polyester meshes. Data analysis was conducted using Python, incorporating machine learning algorithms to assess key clinical parameters including operative time, duration of hospital stay, and postoperative complications. Results: Statistical analysis using independent samples t-tests revealed no significant differences between the two groups in terms of hernia duration, operative time, length of hospital stay, or rate of postoperative complications. Conclusions: Polypropylene and polyester meshes demonstrate comparable performance in Lichtenstein hernia repair with no significant differences in surgical outcomes. Mesh selection may therefore be guided by patient-specific factors, surgeon preference, or cost considerations, rather than expected clinical superiority.
- 27 April 2025
- Published by European Scientific Society in Archiv Euromedica
- Vol. 15 (2)
AI-Based Evaluation of Polypropylene and Polyester Meshes in Lichtenstein Hernia Repair
Aims: This study aimed to evaluate the clinical outcomes of using polypropylene and polyester mesh implants in inguinal hernia repair via the Lichtenstein technique, employing artificial intelligence and machine learning tools for statistical analysis. Methods: A total of 58 patients with primary unilateral inguinal hernias were operated on using the Lichtenstein technique over a three-year period. They were divided into two groups: Group A (38 patients, mean age 58.05 years; 34 males, 4 females) received polypropylene meshes, while Group B (20 patients, mean age 50.05 years; all males) received polyester meshes. Data analysis was conducted using Python, incorporating machine learning algorithms to assess key clinical parameters including operative time, duration of hospital stay, and postoperative complications. Results: Statistical analysis using independent samples t-tests revealed no significant differences between the two groups in terms of hernia duration, operative time, length of hospital stay, or rate of postoperative complications. Conclusions: Polypropylene and polyester meshes demonstrate comparable performance in Lichtenstein hernia repair with no significant differences in surgical outcomes. Mesh selection may therefore be guided by patient-specific factors, surgeon preference, or cost considerations, rather than expected clinical superiority.
- 28 February 2025
- Published by European Scientific Society in Archiv Euromedica
- Vol. 15 (1)
ARTIFICIAL INTELLIGENCE-POWERED INSIGHTS: EXPLORING THE IMPACT OF ARTERIAL HYPERTENSION ON INGUINAL HERNIOPLASTY CONSEQUENCES
Europäische Wissenschaftliche Gesellschaft Home About the Journal Peer Review Editorial Board For Authors Reviewer Recognition Archive Contact Impressum EWG e.V. Elektronische Zeitschriftbibliotek Logo Bielefeld Academic Search Engine Logo Erfolgreich durch internationale Zusammenarbeit AI in Healthcare Cite as: Archiv EuroMedica. 2025. 15; 1. DOI 10.35630/2025/15/1.104 Received 15 January 2025; Accepted 17 February 2025; Published 23 February 2025 ARTIFICIAL INTELLIGENCE-POWERED INSIGHTS: EXPLORING THE IMPACT OF ARTERIAL HYPERTENSION ON INGUINAL HERNIOPLASTY CONSEQUENCES Andrey Protasov 1 orcid id logo, Mekhaeel Mekhaeel1 orcid id logo, Sameh Salem1email orcid id logo, Watban Khalid Al-Tekreeti2 orcid id logo, Eman Abdulqader Abduhalim Abdo3 orcid id logo, Abd Alhakem Alhatem4 orcid id logo 1Department of Operative Surgery and Clinical Anatomy named after I.D. Kirpatovsky. Medical institute. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University), Moscow, Russia 2Department of Mechanical Engineering Technologies, Academy of Engineering. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University), Moscow, Russia. 3Department of Oncology and Roentgenology named after V.P. Kharchenko. Medical Institute. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University), Moscow, Russia 4Department of Surgery. Medical institute. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University). Moscow, Russia download article (pdf) samehhadhoud2020@gmail.com ABSTRACT Aims: To analyze potential influences of primary arterial hypertension in patients with an inguinal hernia after Liechtenstein open inguinal hernia repair by using different types of surgical mesh implants. Method: 40 patients with inguinal hernia were operated by the Lichtenstein repair using different types of mesh implants during the period between January 2022 and the end of December 2024. The patients were splitted into 2 equal groups (no=20); Group A (Normotensive Patients) and Group B (Hypertensive Patients),and the results were analyzed using machine learning Artificial Intelligence programming language; Python. Results: Duration of herniation, total hospitalization stays, time of operation and the incidence of postoperative complications — the results of the t-tests show no statistically significant differences among both groups. Conclusions: In our study, we found that hypertension status does not significantly impacts upon the outcomes of inguinal hernia repair.
- 28 February 2025
- Published by European Scientific Society in Archiv Euromedica
- Vol. 15 (1)
ARTIFICIAL INTELLIGENCE-POWERED INSIGHTS: EXPLORING THE IMPACT OF ARTERIAL HYPERTENSION ON INGUINAL HERNIOPLASTY CONSEQUENCES
Europäische Wissenschaftliche Gesellschaft Home About the Journal Peer Review Editorial Board For Authors Reviewer Recognition Archive Contact Impressum EWG e.V. Elektronische Zeitschriftbibliotek Logo Bielefeld Academic Search Engine Logo Erfolgreich durch internationale Zusammenarbeit AI in Healthcare Cite as: Archiv EuroMedica. 2025. 15; 1. DOI 10.35630/2025/15/1.104 Received 15 January 2025; Accepted 17 February 2025; Published 23 February 2025 ARTIFICIAL INTELLIGENCE-POWERED INSIGHTS: EXPLORING THE IMPACT OF ARTERIAL HYPERTENSION ON INGUINAL HERNIOPLASTY CONSEQUENCES Andrey Protasov 1 orcid id logo, Mekhaeel Mekhaeel1 orcid id logo, Sameh Salem1email orcid id logo, Watban Khalid Al-Tekreeti2 orcid id logo, Eman Abdulqader Abduhalim Abdo3 orcid id logo, Abd Alhakem Alhatem4 orcid id logo 1Department of Operative Surgery and Clinical Anatomy named after I.D. Kirpatovsky. Medical institute. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University), Moscow, Russia 2Department of Mechanical Engineering Technologies, Academy of Engineering. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University), Moscow, Russia. 3Department of Oncology and Roentgenology named after V.P. Kharchenko. Medical Institute. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University), Moscow, Russia 4Department of Surgery. Medical institute. Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University). Moscow, Russia download article (pdf) samehhadhoud2020@gmail.com ABSTRACT Aims: To analyze potential influences of primary arterial hypertension in patients with an inguinal hernia after Liechtenstein open inguinal hernia repair by using different types of surgical mesh implants. Method: 40 patients with inguinal hernia were operated by the Lichtenstein repair using different types of mesh implants during the period between January 2022 and the end of December 2024. The patients were splitted into 2 equal groups (no=20); Group A (Normotensive Patients) and Group B (Hypertensive Patients),and the results were analyzed using machine learning Artificial Intelligence programming language; Python. Results: Duration of herniation, total hospitalization stays, time of operation and the incidence of postoperative complications — the results of the t-tests show no statistically significant differences among both groups. Conclusions: In our study, we found that hypertension status does not significantly impacts upon the outcomes of inguinal hernia repair.
- 26 December 2024
- Published by European Scientific Society in Archiv Euromedica
- Vol. 14 (6)
THE BENEFITS OF USING POLYESTER MESH IMPLANT DURING ANTERIOR INGUINAL HERNIA REPAIR. CASE REPORT
Aims: To find the results of using polyester mesh implant as an optimal alternative to polypropylene for open anterior inguinal hernia repair by Lichtenstein. Case Description: We present a 53-year-old-male patient with uncomplicated right-sided oblique inguinal hernia. Reinforcement of the posterior wall of the inguinal canal was done using polyester mesh implant fixed by dacron sutures. Successful repair was achieved with reduced operative-time and smooth recovery free from complications during post-operative and short-term follow-up intervals. Conclusions: Polyester mesh implant could be considered an optimal alternative to polypropylene for open anterior inguinal hernia repair.
- 26 December 2024
- Published by European Scientific Society in Archiv Euromedica
- Vol. 14 (6)
THE BENEFITS OF USING POLYESTER MESH IMPLANT DURING ANTERIOR INGUINAL HERNIA REPAIR. CASE REPORT
Aims: To find the results of using polyester mesh implant as an optimal alternative to polypropylene for open anterior inguinal hernia repair by Lichtenstein. Case Description: We present a 53-year-old-male patient with uncomplicated right-sided oblique inguinal hernia. Reinforcement of the posterior wall of the inguinal canal was done using polyester mesh implant fixed by dacron sutures. Successful repair was achieved with reduced operative-time and smooth recovery free from complications during post-operative and short-term follow-up intervals. Conclusions: Polyester mesh implant could be considered an optimal alternative to polypropylene for open anterior inguinal hernia repair.
- 26 December 2024
- Published by European Scientific Society in Archiv Euromedica
- Vol. 14 (6)
OUTCOMES OF A PEDIATRIC FACIAL FRACTURE RECONSTRICTION. CASE REPORT
Aims: Studying the results of the reconstruction of pediatric multi-facial fracture. Case Description: In our study we present a 13-year-old boy with facial oedema, oral pain and bleeding due to falling from height. Upon examination, the patient had a left parasymphysial mandibular fracture and maxillary fracture Le fort I. Conclusions: A combined closed reduction with intermaxillary fixation and maxillary-frontal suspension and open reduction using interosseous wiring had restored the preoperative anatomical, functional and cosmetic aspects of the patient, which was found to be a reliable, cost-effective method for surgical management of pediatric facial trauma.
- 26 December 2024
- Published by European Scientific Society in Archiv Euromedica
- Vol. 14 (6)
OUTCOMES OF A PEDIATRIC FACIAL FRACTURE RECONSTRICTION. CASE REPORT
Aims: Studying the results of the reconstruction of pediatric multi-facial fracture. Case Description: In our study we present a 13-year-old boy with facial oedema, oral pain and bleeding due to falling from height. Upon examination, the patient had a left parasymphysial mandibular fracture and maxillary fracture Le fort I. Conclusions: A combined closed reduction with intermaxillary fixation and maxillary-frontal suspension and open reduction using interosseous wiring had restored the preoperative anatomical, functional and cosmetic aspects of the patient, which was found to be a reliable, cost-effective method for surgical management of pediatric facial trauma.
- Open Access
- 15 December 2024
- Published by Peoples' Friendship University of Russia in RUDN Journal of Medicine
- Vol. 28 (4) , 499-507
The choice of the optimal mesh implant for hernioplasty operations depending on the properties of mesh implants
Silver and titanium were the first used elements in the era of hernia-strengthening biomaterials about a hundred years ago, reaching up to 150 types nowadays. The uniqueness of Deeken and Lake Mesh Classification system is its dependence of the properties of the used materials in classifying them, where three main categories of meshes was established; permanent synthetic, absorbable (of biological origin) derived; furtherly divided into composite, non-composite types, and hybrid meshes. The physical characteristics of each category are determined by the pore size, thread diameter, thickness and density. Moreover, tear resistance, suture retention, uniaxial tensile and planar biaxial tensile testing, ball burst, make it possible to refine the properties of the mesh implant. This article is devoted to understanding the types of mesh materials used for repair of the anterolateral abdominal wall hernias by highlighting the properties of their scaffold materials, coating and barriers, as well as their improvement through coating by different several materials improving their properties in order to meet the needs of sufficient and satisfactory hernia repair seeking for leadership in choosing mesh implants.
- 15 December 2024
- Published by Peoples' Friendship University of Russia in RUDN Journal of Medicine
- Vol. 28 (4) , 499-507
Open AccessThe choice of the optimal mesh implant for hernioplasty operations depending on the properties of mesh implants
Silver and titanium were the first used elements in the era of hernia-strengthening biomaterials about a hundred years ago, reaching up to 150 types nowadays. The uniqueness of Deeken and Lake Mesh Classification system is its dependence of the properties of the used materials in classifying them, where three main categories of meshes was established; permanent synthetic, absorbable (of biological origin) derived; furtherly divided into composite, non-composite types, and hybrid meshes. The physical characteristics of each category are determined by the pore size, thread diameter, thickness and density. Moreover, tear resistance, suture retention, uniaxial tensile and planar biaxial tensile testing, ball burst, make it possible to refine the properties of the mesh implant. This article is devoted to understanding the types of mesh materials used for repair of the anterolateral abdominal wall hernias by highlighting the properties of their scaffold materials, coating and barriers, as well as their improvement through coating by different several materials improving their properties in order to meet the needs of sufficient and satisfactory hernia repair seeking for leadership in choosing mesh implants.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Operative Surgery and Clinical Anatomy
- Vol. 8 (4)
Outcomes of using both self-gripping mesh and polypropylene meshes fixed by tacks in Liechtenstein repair
Objective. Finding out the results of using two kinds of mesh implants: self-gripping mesh implants and polypropylene mesh fixed by tacks in open inguinal hernioplasty by Liechtenstein focusing on the way of mesh fixation. Material and methods. Our study was conducted upon 100 patients with inguinal hernia, which were divided into two equal groups (no=50). AdhesixTM self- gripping mesh implants was utilized in the first group, while polypropylene mesh implants fixed by elastic absorb tack fixing device were used in the second group. The duration of the operation, quantity of hospital stays (beds/day), postoperative complications and complications during the short-term follow-up were estimated. Results. Self-gripping mesh implants were superior to polypropylene mesh fixed by elastic tacks regarding operative time (8 minutes less), incidence of post-operative pain (28% less) and also foreign body sensation (34% less) during the short-term follow-up. Conclusion. We can recommend using self-gripping mesh in practice when the choice of surgeon well be between self-gripping mesh and polypropylene mesh fixed by tacks.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Operative Surgery and Clinical Anatomy
- Vol. 8 (4)
Outcomes of using both self-gripping mesh and polypropylene meshes fixed by tacks in Liechtenstein repair
Objective. Finding out the results of using two kinds of mesh implants: self-gripping mesh implants and polypropylene mesh fixed by tacks in open inguinal hernioplasty by Liechtenstein focusing on the way of mesh fixation. Material and methods. Our study was conducted upon 100 patients with inguinal hernia, which were divided into two equal groups (no=50). AdhesixTM self- gripping mesh implants was utilized in the first group, while polypropylene mesh implants fixed by elastic absorb tack fixing device were used in the second group. The duration of the operation, quantity of hospital stays (beds/day), postoperative complications and complications during the short-term follow-up were estimated. Results. Self-gripping mesh implants were superior to polypropylene mesh fixed by elastic tacks regarding operative time (8 minutes less), incidence of post-operative pain (28% less) and also foreign body sensation (34% less) during the short-term follow-up. Conclusion. We can recommend using self-gripping mesh in practice when the choice of surgeon well be between self-gripping mesh and polypropylene mesh fixed by tacks.