Wenhao Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenhao Huang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Fang Tian
School of Architecture and Art, Hebei University of Engineering, Handan 056038, China
2 shared publications - Tengfei Huang
College of Architecture and Art, Hebei University of Engineering, Handan 056038, China
1 shared publication - Tengfei Huang
School of Architecture and Art, Hebei University of Engineering, Handan 056038, China
1 shared publication
Latest Publications
- Open Access
Multi-Objective Optimization of Residential Block Space Morphology in Xingtai City Under Energy-Saving Orientation
Studies have shown that the morphology of residential blocks has a significant impact on the buildings’ energy use intensity (EUI), solar energy utilization potential (SEUP), and average sunlight hours (ASH). This paper utilizes the Rhino and Grasshopper platforms, employing the Wallacei multi-objective optimization algorithm, to study the relationship between the morphology of residential blocks in Xingtai City, EUI, SEUP, and ASH. First, 108 residential blocks in Xingtai City were surveyed, based on varying design criteria, they were classified into three categories: multi-story, high-rise Type I, and high-rise Type II. Next, after integrating microclimatic factors, the Wallacei multi-objective optimization algorithm was employed to optimize three objectives: EUI, SEUP, and ASH. Finally, the simulation results were subjected to a quantitative analysis using statistical methods, such as K-means clustering. The spatial morphology of residential blocks had a maximum impact of 11.69% on EUI, 39.8% on SEUP, and 36.85% on ASH. Therefore, energy saving can be achieved by controlling the building density, average number of floors, building shape factor and other morphological indicators of residential blocks.
Open AccessMulti-Objective Optimization of Residential Block Space Morphology in Xingtai City Under Energy-Saving Orientation
Studies have shown that the morphology of residential blocks has a significant impact on the buildings’ energy use intensity (EUI), solar energy utilization potential (SEUP), and average sunlight hours (ASH). This paper utilizes the Rhino and Grasshopper platforms, employing the Wallacei multi-objective optimization algorithm, to study the relationship between the morphology of residential blocks in Xingtai City, EUI, SEUP, and ASH. First, 108 residential blocks in Xingtai City were surveyed, based on varying design criteria, they were classified into three categories: multi-story, high-rise Type I, and high-rise Type II. Next, after integrating microclimatic factors, the Wallacei multi-objective optimization algorithm was employed to optimize three objectives: EUI, SEUP, and ASH. Finally, the simulation results were subjected to a quantitative analysis using statistical methods, such as K-means clustering. The spatial morphology of residential blocks had a maximum impact of 11.69% on EUI, 39.8% on SEUP, and 36.85% on ASH. Therefore, energy saving can be achieved by controlling the building density, average number of floors, building shape factor and other morphological indicators of residential blocks.
- Open Access
Energy Performance-Oriented Multi-Objective Optimization of Spatial Form of High-Rise Residential Blocks in the Changsha Region
Optimizing urban spatial form has become an important research topic for promoting urban sustainable development and improving energy efficiency. This study selects 164 high-rise residential blocks in the Changsha area as the research object and constructs three multi-objective optimization frameworks and mathematical models for the spatial form of high-rise residential blocks based on the Rhino and Grasshopper parametric platform. The TOPSIS comprehensive evaluation method is combined to further screen the Pareto front solutions, and global sensitivity analysis of spatial form parameters is conducted using Simlab to explore the multi-objective optimization strategies for the spatial form of high-rise residential blocks in the Changsha area, guided by energy performance. Practical cases are selected for verification. The results show that, (1) after multi-objective optimization, the optimal scheme for the determinant type reduces EUI by 7.22%, increases PVP by 28.84%, and reduces CGR by 2.21%. The optimal scheme for the point-cluster type reduces EUI by 3.80%, increases PVP by 7.34%, and reduces CGR by 2.30%. The optimal scheme for the staggered type reduces EUI by 6.66%, increases PVP by 17.65%, and reduces CGR by 2.26%. (2) The potential order of spatial form optimization for the three types of high-rise residential blocks in the Changsha area is determinant type > staggered type > point-cluster type. (3) The spatial form parameters most sensitive to the three architectural performance goals of EUI, PVP, and CGR are floor area ratio and average number of floors. The research results will provide quantifiable references for scientific decision-making in the design practice of high-rise residential blocks in the Changsha area and even in regions with hot summers and cold winters.
Open AccessEnergy Performance-Oriented Multi-Objective Optimization of Spatial Form of High-Rise Residential Blocks in the Changsha Region
Optimizing urban spatial form has become an important research topic for promoting urban sustainable development and improving energy efficiency. This study selects 164 high-rise residential blocks in the Changsha area as the research object and constructs three multi-objective optimization frameworks and mathematical models for the spatial form of high-rise residential blocks based on the Rhino and Grasshopper parametric platform. The TOPSIS comprehensive evaluation method is combined to further screen the Pareto front solutions, and global sensitivity analysis of spatial form parameters is conducted using Simlab to explore the multi-objective optimization strategies for the spatial form of high-rise residential blocks in the Changsha area, guided by energy performance. Practical cases are selected for verification. The results show that, (1) after multi-objective optimization, the optimal scheme for the determinant type reduces EUI by 7.22%, increases PVP by 28.84%, and reduces CGR by 2.21%. The optimal scheme for the point-cluster type reduces EUI by 3.80%, increases PVP by 7.34%, and reduces CGR by 2.30%. The optimal scheme for the staggered type reduces EUI by 6.66%, increases PVP by 17.65%, and reduces CGR by 2.26%. (2) The potential order of spatial form optimization for the three types of high-rise residential blocks in the Changsha area is determinant type > staggered type > point-cluster type. (3) The spatial form parameters most sensitive to the three architectural performance goals of EUI, PVP, and CGR are floor area ratio and average number of floors. The research results will provide quantifiable references for scientific decision-making in the design practice of high-rise residential blocks in the Changsha area and even in regions with hot summers and cold winters.