YSYasaman Safarkhanlo

Yasaman Safarkhanlo

*This is an algorithmically generated author record based on publicly available information.

Yasaman Safarkhanlo has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Jessica A. M. Bastiaansen

    Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital Bern University Hospital, University of Bern Bern Switzerland

    4 shared publications
  • Adèle L. C. Mackowiak

    Department of Radiology Lausanne University Hospital and University of Lausanne Lausanne Switzerland

    3 shared publications
  • Nils M. J. Plähn

    Department of Diagnostic, Interventional and Pediatric Radiology (DIPR) Inselspital, Bern University Hospital, University of Bern Bern Switzerland

    3 shared publications
  • Benedikt Bernhard

    Noninvasive Cardiovascular Imaging Section, Cardiovascular Division, Department of Medicine and Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts, USA

    2 shared publications
  • Berk C. Açikgöz

    Department of Diagnostic, Interventional and Pediatric Radiology (DIPR) Inselspital, Bern University Hospital, University of Bern Bern Switzerland

    2 shared publications
  • Davide Piccini

    Scientific Collaborations and Strategic Partnerships, Siemens Healthcare Srl Milano Italy

    2 shared publications

Latest Publications

  • Open Access

    Pole‐To‐Pole 3D Radial Trajectory Designs Improve Image Quality and Quantitative Parametric Mapping in the Brain and Heart

    by Eva S. Peper, Grzegorz Bauman, Matteo Tagliabue, Berk C. Açikgöz, Nils M. J. Plähn, Adèle L. C. Mackowiak, Yasaman Safarkhanlo, Joseph G. Woods, Davide Piccini, Li Feng, et al.

    Purpose: To design 3D radial spiral phyllotaxis trajectories aimed at removing phase inconsistencies, improving image quality, and enhancing parametric mapping accuracy by acquiring nearly opposing spokes starting from both hemispheres in 3D radial k ‐space. Methods: Two 3D radial trajectories, pole‐to‐pole and continuous spiral phyllotaxis, were developed and implemented on a 3T MRI scanner in a phase‐cycled balanced steady‐state free precession (bSSFP) and a spoiled gradient‐echo (GRE) sequence. Image quality and k ‐space center phase variations were evaluated in a spherical phantom using the original and new radial phyllotaxis designs. T1/T2 was quantified and compared using phase‐cycled bSSFP data acquired with the new radial trajectory designs, as well as the original phyllotaxis trajectory and a Cartesian trajectory as references, in both an MRI system phantom and the brains of three healthy volunteers. ECG‐triggered whole‐heart GRE data were acquired using the original and pole‐to‐pole phyllotaxis trajectories in three healthy volunteers and compared for image quality improvement. Results: All 3D radial trajectory designs showed variations in the k ‐space center phase depending on the orientation of the readout spokes. Image quality improved when using the pole‐to‐pole and continuous phyllotaxis over the original trajectory. Scans using the original trajectory had higher T1/T2 estimation errors in comparison to the new trajectories and the Cartesian trajectory. The pole‐to‐pole and continuous trajectories improved T1/T2 maps of the brain and image quality for all cardiac images. Conclusion: Acquiring nearly opposing spokes in 3D radial trajectory designs compensates phase inconsistencies without requiring additional corrections, which improves quantitative imaging and anatomical visualizations.


  • Open Access

    Quantitative susceptibility mapping in the human brain at 7T with phase‐cycled balanced SSFP

    by Berk Can Acikgoz, Cristina Sainz Martinez, Adèle L. C. Mackowiak, Nils M. J. Plähn, Yasaman Safarkhanlo, Eva S. Peper, Piotr Radojewski, Gabriele Bonanno, João Jorge, Jessica A. M. Bastiaansen

    Purpose: To demonstrate the feasibility of QSM and to show the potential of simultaneous , , and proton density (PD) mapping in the human brain at 7T based on phase‐cycled balanced SSFP (bSSFP) MRI. Methods: An algorithm was developed to estimate off‐resonance frequency in multi‐compartment scenarios by combining elliptic phase‐cycled bSSFP signal fitting with dictionary matching. Phase‐cycled bSSFP‐based tissue phase and susceptibility maps were compared with multi‐echo gradient‐echo (MEGRE)‐based maps in the brains of eight healthy subjects at 7T. Additionally, , , and PD maps were obtained from the same phase‐cycled bSSFP data. To demonstrate the potential of matching scan time with MEGRE, bSSFP profiles were subsampled by 50% and resulting maps compared with the reference data. Results: The tissue phase maps obtained from phase‐cycled bSSFP data agreed well with the reference, with a mean absolute deviation of Hz in the entire brain of all subjects. The mean absolute deviation of tissue susceptibility was parts‐per‐billion (ppb). Susceptibility in the globus pallidus was overestimated by 67 ppb ( p < 0.05), while no significant biases were observed in other regions: 3.2 ppb in putamen, 15.5 ppb in thalamus, and 11.9 ppb in caudate nucleus (all p > 0.05). Quantitative maps showed good contrast between different regions of the brain, aligning well with the literature. Profile subsampling did not significantly ( p > 0.05) change the quantitative susceptibility maps. Conclusion: The feasibility of phase‐cycled bSSFP for QSM at 7T was demonstrated, with the added benefit of simultaneous , , and PD mapping, with a total scan time of ˜20 min.


  • Open Access

    Evaluating rapid water excitation techniques for 5D whole-heart fat-suppressed free-running cardiac MRI at 1.5T scanner

    by Yasaman Safarkhanlo, Jérôme Yerly, Mariana B. L. Falcão, Adele L. C. Mackowiak, Davide Piccini, Matthias Stuber, Bernd Jung, Christoph Graeni, Jessica A. M. Bastiaansen

    Background: Balanced steady-state free precession (bSSFP) sequences offer high SNR and excellent tissue contrast for whole-heart MRI. However, inadequate fat suppression can introduce artifacts, particularly with non-Cartesian readouts. This study aimed to compare novel rapid water-excitation (WE) pulses for 3D radial whole-heart free-running MRI at 1.5T, specifically Binomial Off-Resonant Rectangular (BORR), Lipid Insensitive Binomial Off-Resonant RF Excitation (LIBRE), and Lipid Insensitive Binomial Off-Resonant (LIBOR) pulses, alongside a Fast Interrupted Steady-State (FISS) and non-fat suppressed free-running bSSFP sequence. Methods: Three free-running MRI protocols (BORR, LIBRE, LIBOR) were optimized for fat suppression at 1.5T using a phantom. These protocols, along with FISS and non-fat suppressed bSSFP, were tested in phantom and five volunteers, with each acquisition lasting 3min and 41sec. SNR and CNR Water-Fat were measured in phantom data, while SNR and CNR Blood-Myocardium were assessed in volunteers using static gridded reconstructions. Motion-resolved reconstructions were used for qualitative assessments. SAR values were measured for each sequence, and statistical differences were analyzed using one-way ANOVA (p < 0.05). The pulse with the best combination of high SNR and low SAR was identified for further applications. Results: In phantom studies, LIBOR had the highest CNR Water-Fat (276.8 ± 2.5), followed by LIBRE (268.1 ± 2.6), BORR (249.9 ± 2.2), and FISS (212.7 ± 2.7), though these differences were not statistically significant (p > 0.05). FISS showed the highest SAR (1.41 W.kg -1 ), while LIBOR had the lowest (0.23 W.kg -1 ). In volunteers, BORR had the highest SNR in the ventricular blood pool (17.0 ± 1.5), and LIBRE had the highest CNR Blood-Fat (29.4 ± 9.3). FISS had the highest CNR Blood-Myocardium (29.0 ± 8.9), but the differences were not significant (p > 0.05). LIBOR consistently had the lowest SAR (0.26 W.kg -1 ). Conclusion: This study compared various fat-signal-suppression approaches in 3D contrast-free whole-heart free-running bSSFP MRI at 1.5T. Although the sequences performed similarly in SNR and CNR, LIBOR offered the lowest SAR, making it a promising candidate for future whole-heart MRI applications, particularly where RF energy deposition is a concern.

  • ORACLE: An analytical approach for T 1 , T 2 , proton density, and off‐resonance mapping with phase‐cycled balanced steady‐state free precession

    by Nils M. J. Plähn, Yasaman Safarkhanlo, Berk C. Açikgöz, Adèle L. C. Mackowiak, Piotr Radojewski, Gabriele Bonanno, Eva S. Peper, Rahel Heule, Jessica A. M. Bastiaansen

    Purpose: To develop and validate a novel analytical approach simplifying , , proton density (PD), and off‐resonance quantifications from phase‐cycled balanced steady‐state free precession (bSSFP) data. Additionally, to introduce a method to correct aliasing effects in undersampled bSSFP profiles. Theory and Methods: Off‐resonant‐encoded analytical parameter quantification using complex linearized equations (ORACLE) provides analytical solutions for bSSFP profiles. which instantaneously quantify , , proton density (PD), and . An aliasing correction formalism was derived to allow undersampling of bSSFP profiles. ORACLE was used to quantify , , PD, /, and based on fully sampled () bSSFP profiles from numerical simulations and 3T MRI experiments in phantom and 10 healthy subjects' brains. Obtained values were compared with reference scans in the same scan session. Aliasing correction was validated in subsampled () bSSFP profiles in numerical simulations and human brains. Results: ORACLE quantifications agreed well with input values from simulations and phantom reference values ( R 2 = 0.99). In human brains, and quantifications when compared with reference methods showed coefficients of variation below 2.9% and 3.9%, biases of 182 and 16.6 ms, and mean white‐matter values of 642 and 51 ms using ORACLE. The quantification differed less than 3 Hz between both methods. PD and maps had comparable histograms. The maps effectively identified cerebrospinal fluid. Aliasing correction removed aliasing‐related quantification errors in undersampled bSSFP profiles, significantly reducing scan time. Conclusion: ORACLE enables simplified and rapid quantification of , , PD, and from phase‐cycled bSSFP profiles, reducing acquisition time and eliminating biomarker maps' coregistration issues.


  • Open Access

    Predictive value of diastolic function assessed by CMR feature tracking in patients with suspected myocarditis and preserved left ventricular ejection fraction

    by J Schuetze, A W Stark, B Bernhard, Y Safarkhanlo, G Spano, M Boscolo, R Y Kwong, C Graeni

    Funding Acknowledgements: Type of funding sources: None. Background: Reduced left ventricular systolic function is a well established predictor for outcome in Patients with myocarditis. However, the predictive role of diastolic function in patients with suspected myocarditis and preserved ejection fraction is unknown. Purpose: Assess the predicative value of diastolic left ventricular function in patients with suspected myocarditis. Methods: Late and early radial, circumferential and longitudinal diastolic strain rate was assessed as using CMR feature tracking in patients with clinically suspected myocarditis being referred for cardiac magnetic resonance imaging (CMR). The primary endpoint was defined as a composite of first major adverse cardiovascular events (MACE) including all-cause mortality, sustained ventricular tachycardia and hospitalization for heart failure. Results: 755 consecutive patients with suspected myocarditis and referred for CMR (277, 37% female; mean age 48 ± 16years) were included. Of those late gadolinium enhancement (LGE) was present in 417 (55.2%). 416 had a preserved ejection fraction >50% (55.1%). Mace was documented in 123 patients (16.3%) during a median observational time of 3.77 years. After adjustment for LVEF, LGE extend, age, and gender early circumferential strain rate (HR=0.35 95% CI 0.16–0.77, p = 0.009), early longitudinal diastolic strain rate (HR=0.40 95% CI 0.17–0.96, p = 0.042) and late diastolic strain rate (HR=0.23 95% CI 0.07–0.74, p = 0.013) remained independent predictors of MACE. Conclusion: CMR feature tracking diastolic strain rate is independently associated with outcome, beyond LVEF and LGE in patients with myocarditis, and might therefore contribute to improved risk stratification in this sclinical setting.


  • Open Access

    Mitral valve regurgitation assessed by intraventricular CMR 4D-flow: a systematic review on the technological aspects and potential clinical applications

    by Yasaman Safarkhanlo, Bernd Jung, Benedikt Bernhard, Eva S. Peper, Raymond Y. Kwong, Jessica A. M. Bastiaansen, Christoph Gräni

    Cardiac magnetic resonance (CMR) four-dimensional (4D) flow is a novel method for flow quantification potentially helpful in management of mitral valve regurgitation (MVR). In this systematic review, we aimed to depict the clinical role of intraventricular 4D-flow in MVR. The reproducibility, technical aspects, and comparison against conventional techniques were evaluated. Published studies on SCOPUS, MEDLINE, and EMBASE were included using search terms on 4D-flow CMR in MVR. Out of 420 screened articles, 18 studies fulfilled our inclusion criteria. All studies (n = 18, 100%) assessed MVR using 4D-flow intraventricular annular inflow (4D-flowAIM) method, which calculates the regurgitation by subtracting the aortic forward flow from the mitral forward flow. Thereof, 4D-flow jet quantification (4D-flowjet) was assessed in 5 (28%), standard 2D phase-contrast (2D-PC) flow imaging in 8 (44%) and the volumetric method (the deviation of left ventricle stroke volume and right ventricular stroke volume) in 2 (11%) studies. Inter-method correlations among the 4 MVR quantification methods were heterogeneous across studies, ranging from moderate to excellent correlations. Two studies compared 4D-flowAIM to echocardiography with moderate correlation. In 12 (63%) studies the reproducibility of 4D-flow techniques in quantifying MVR was studied. Thereof, 9 (75%) studies investigated the reproducibility of the 4D-flowAIM method and the majority (n = 7, 78%) reported good to excellent intra- and inter-reader reproducibility. Intraventricular 4D-flowAIM provides high reproducibility with heterogeneous correlations to conventional quantification methods. Due to the absence of a gold standard and unknown accuracies, future longitudinal outcome studies are needed to assess the clinical value of 4D-flow in the clinical setting of MVR.