Xiangliang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiangliang Zhang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jiazhi Lei
School of Intelligent Manufacturing, Huzhou College, Huzhou 313000, China
2 shared publications - Minxiu Guan
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China
1 shared publication - Xiaoyuan Chen
School of Intelligent Manufacturing, Huzhou College, Huzhou 313000, China
1 shared publication
Latest Publications
- Open Access
A Method of Faulty Section Location Based on Algebraic Sum of Feeder Current Fault Component
When a positive pole grounding fault (PPGF) occurs in a certain zone of the straddle-type monorail (STM) DC traction system (DCTS), this causes multiple 64D grounding protections to activate and the circuit breaker of the DC feeder to trip. The protection loses selectivity and leads to a large-area power outage of the DCTS. It is necessary to locate the fault zone as soon as possible in order to reduce the impact of the accident. Firstly, this paper analyzes the simplified equivalent model of the DCTS fault component in case of PPGF and the equivalent model of DCTS in case of sudden entry of a locomotive. Secondly, it analyzes characteristic differences in the magnitude of the algebraic sum of fault current components (M-ASFCC) for the locomotive-free area, faulty area, and locomotive area based on the above two equivalent models, respectively. Then, it derives the characteristic differences in M-ASFCC of the three types of sections when PPGF occurs simultaneously with the sudden entry of the locomotive according to the law of superposition. After that, the faulty section location (FSL) method was proposed based on the feeder algebraic sum of fault current components (ASFCC). It should be noted that the theoretical derivation of the proposed method is based on a linearized small-signal approximation at the fault instant. The constant-power locomotive load with power electronic converters is approximated as a fixed impedance, which is only valid under minor voltage disturbance at the moment of fault inception. If the M-ASFCC of a zone in the DCTS exceeds the setting value, the zone is judged to be faulty; otherwise, it is identified as normal. Finally, the proposed method is verified by MATLAB R2019b simulations that can locate the fault section quickly and accurately, which lays a good foundation for subsequent fault processing. Compared to other methods, the method has higher protection sensitivity and can withstand larger transition resistance (TR).
Open AccessA Method of Faulty Section Location Based on Algebraic Sum of Feeder Current Fault Component
When a positive pole grounding fault (PPGF) occurs in a certain zone of the straddle-type monorail (STM) DC traction system (DCTS), this causes multiple 64D grounding protections to activate and the circuit breaker of the DC feeder to trip. The protection loses selectivity and leads to a large-area power outage of the DCTS. It is necessary to locate the fault zone as soon as possible in order to reduce the impact of the accident. Firstly, this paper analyzes the simplified equivalent model of the DCTS fault component in case of PPGF and the equivalent model of DCTS in case of sudden entry of a locomotive. Secondly, it analyzes characteristic differences in the magnitude of the algebraic sum of fault current components (M-ASFCC) for the locomotive-free area, faulty area, and locomotive area based on the above two equivalent models, respectively. Then, it derives the characteristic differences in M-ASFCC of the three types of sections when PPGF occurs simultaneously with the sudden entry of the locomotive according to the law of superposition. After that, the faulty section location (FSL) method was proposed based on the feeder algebraic sum of fault current components (ASFCC). It should be noted that the theoretical derivation of the proposed method is based on a linearized small-signal approximation at the fault instant. The constant-power locomotive load with power electronic converters is approximated as a fixed impedance, which is only valid under minor voltage disturbance at the moment of fault inception. If the M-ASFCC of a zone in the DCTS exceeds the setting value, the zone is judged to be faulty; otherwise, it is identified as normal. Finally, the proposed method is verified by MATLAB R2019b simulations that can locate the fault section quickly and accurately, which lays a good foundation for subsequent fault processing. Compared to other methods, the method has higher protection sensitivity and can withstand larger transition resistance (TR).
- Open Access
Bi-Level Optimization Scheduling Strategy for PIES Considering Uncertainties of Price-Based Demand Response
The asymmetry-induced uncertainty in both sources and loads is a crucial and continuously spotlighted issue within modern power systems. Applying optimization scheduling method to deal with this asymmetry is a feasible solution. Accordingly, this paper proposes a bi-level park-level integrated energy system (PIES) optimization strategy considering uncertainties of price-based load demand response (PLDR). Firstly, a model for characterizing the uncertainties of the PLDR is developed based on fuzzy theory. Secondly, a bi-level two-stage PIES optimization model that includes multiple device models is established. In the first stage, the dynamic pricing optimization is carried out with the aim of maximizing user satisfaction. In the second stage, the PIES scheduling strategy optimization is performed with the aim of minimizing the operation costs of PIES. Finally, multiple scenarios are set to conduct comparative validation, which demonstrates that the proposed method not only improves the renewable energy integration capacity of the system, optimizes the load profiles, and enhances the economic and low-carbon performance, but also increases user satisfaction, thus providing a reference for the dispatch and operation of the park-level integrated energy system.
Open AccessBi-Level Optimization Scheduling Strategy for PIES Considering Uncertainties of Price-Based Demand Response
The asymmetry-induced uncertainty in both sources and loads is a crucial and continuously spotlighted issue within modern power systems. Applying optimization scheduling method to deal with this asymmetry is a feasible solution. Accordingly, this paper proposes a bi-level park-level integrated energy system (PIES) optimization strategy considering uncertainties of price-based load demand response (PLDR). Firstly, a model for characterizing the uncertainties of the PLDR is developed based on fuzzy theory. Secondly, a bi-level two-stage PIES optimization model that includes multiple device models is established. In the first stage, the dynamic pricing optimization is carried out with the aim of maximizing user satisfaction. In the second stage, the PIES scheduling strategy optimization is performed with the aim of minimizing the operation costs of PIES. Finally, multiple scenarios are set to conduct comparative validation, which demonstrates that the proposed method not only improves the renewable energy integration capacity of the system, optimizes the load profiles, and enhances the economic and low-carbon performance, but also increases user satisfaction, thus providing a reference for the dispatch and operation of the park-level integrated energy system.