Jia Yi Loh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jia Yi Loh has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Lei Jiang
Department of Orthopaedic Surgery, Singapore General Hospital, Singapore
3 shared publications - Kenny Tay
Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore
2 shared publications - Yee Gen Lim
Singapore General Hospital, Singapore, Singapore
2 shared publications - Chengjun Teo
Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore
1 shared publication - Dickson Hong Him Chau
Department of Orthopaedic Surgery, Sengkang General Hospital, Singapore 544886, Singapore
1 shared publication - Joyce Suang Bee Koh
Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore
1 shared publication
Latest Publications
- 24 March 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 177
Determinants of patient satisfaction and expectation after hip fracture surgery: a multidimensional perspective on association between clinical outcomes, subjective expectations and psychosocial factors
- 24 March 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 177
Determinants of patient satisfaction and expectation after hip fracture surgery: a multidimensional perspective on association between clinical outcomes, subjective expectations and psychosocial factors
- Open Access
- 2 March 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (3) , 533-540
Computer-navigated transfacet uniportal endoscopic lumbar interbody fusion: a novel technique and illustrative case series
Conventional interlaminar and trans-Kambin uniportal endoscopic lumbar interbody fusion (U-ELIF) approaches have inherent limitations and risk of injury to neural structures.
- 2 March 2026
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 20 (3) , 533-540
Open AccessComputer-navigated transfacet uniportal endoscopic lumbar interbody fusion: a novel technique and illustrative case series
Conventional interlaminar and trans-Kambin uniportal endoscopic lumbar interbody fusion (U-ELIF) approaches have inherent limitations and risk of injury to neural structures.
- Open Access
- 1 January 2026
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 34 (1)
Big data and artificial intelligence in Orthopaedics: Trends and future directions
Orthopaedic surgery is on the cusp of entering a new data-driven era, fuelled by big data and Artificial Intelligence (AI). Medical data is traditional derived from manually inputted medical records. A far richer set of data may be collected via automated means and from population registries leading to an explosion of large and complex datasets termed “big data” which are not well handled by traditional processing tools. Big data truly becomes useful when coupled with the ability to meaningfully process it with current generation AI. These two advances have reshaped possibilities in research and clinical applications. This narrative review outlines emerging opportunities and challenges brought about big data and AI while also exploring the necessary guardrails that are needed for safe application and sustainable progress.
- 1 January 2026
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 34 (1)
Open AccessBig data and artificial intelligence in Orthopaedics: Trends and future directions
Orthopaedic surgery is on the cusp of entering a new data-driven era, fuelled by big data and Artificial Intelligence (AI). Medical data is traditional derived from manually inputted medical records. A far richer set of data may be collected via automated means and from population registries leading to an explosion of large and complex datasets termed “big data” which are not well handled by traditional processing tools. Big data truly becomes useful when coupled with the ability to meaningfully process it with current generation AI. These two advances have reshaped possibilities in research and clinical applications. This narrative review outlines emerging opportunities and challenges brought about big data and AI while also exploring the necessary guardrails that are needed for safe application and sustainable progress.
- Open Access
- 31 December 2024
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (1)
Hypermagnesemia- and Hyperphosphatemia-Associated Cardiac Arrest after Injection of a Novel Magnesium-Based Bone Cement in Spinal Surgery
We report a case of pulseless electrical activity (PEA) associated with profound hypermagnesemia immediately after cementation of a novel magnesium-based cement in spine surgery. During T8 to T12 posterior instrumentation and decompression laminectomy for vertebral metastasis secondary to lung cancer, a 61-year-old Chinese woman developed sudden hypotension and went into PEA immediately after injection of a novel magnesium-based cement. Intraoperative fluoroscopic imaging did not show any notable cement extravasation. Resuscitation using intravenous epinephrine with five doses of 1-mg epinephrine in 1:10,000 dilution was instituted, and the patient had return of spontaneous circulation after 5 minutes. After successful resuscitation, surgery was expedited and completed. Intraoperative and postoperative investigations were notable for profound hypermagnesemia and hyperphosphatemia requiring diuresis. No echocardiographic or computerized tomographic evidence of pulmonary embolism was found. The patient was transferred to the surgical intensive care unit and remained on dual inotropic support over the next few days. She subsequently weaned off inotropic support and electrolyte imbalances resolved before making a full recovery. This case report demonstrates the severe magnesium toxicity and PEA related to the use of novel magnesium-based cement in spine surgery. Further studies need to be conducted to understand the potential complications related to its use and compare them to the standard bone cement implantation syndrome.
- 31 December 2024
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (1)
Open AccessHypermagnesemia- and Hyperphosphatemia-Associated Cardiac Arrest after Injection of a Novel Magnesium-Based Bone Cement in Spinal Surgery
We report a case of pulseless electrical activity (PEA) associated with profound hypermagnesemia immediately after cementation of a novel magnesium-based cement in spine surgery. During T8 to T12 posterior instrumentation and decompression laminectomy for vertebral metastasis secondary to lung cancer, a 61-year-old Chinese woman developed sudden hypotension and went into PEA immediately after injection of a novel magnesium-based cement. Intraoperative fluoroscopic imaging did not show any notable cement extravasation. Resuscitation using intravenous epinephrine with five doses of 1-mg epinephrine in 1:10,000 dilution was instituted, and the patient had return of spontaneous circulation after 5 minutes. After successful resuscitation, surgery was expedited and completed. Intraoperative and postoperative investigations were notable for profound hypermagnesemia and hyperphosphatemia requiring diuresis. No echocardiographic or computerized tomographic evidence of pulmonary embolism was found. The patient was transferred to the surgical intensive care unit and remained on dual inotropic support over the next few days. She subsequently weaned off inotropic support and electrolyte imbalances resolved before making a full recovery. This case report demonstrates the severe magnesium toxicity and PEA related to the use of novel magnesium-based cement in spine surgery. Further studies need to be conducted to understand the potential complications related to its use and compare them to the standard bone cement implantation syndrome.