Shuang Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shuang Jiang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Tao Le
Chongqing Key Laboratory of Conservation and Utilization of Freshwater Fishes, College of Life Sciences, Chongqing Normal University, Chongqing, China
6 shared publications Xiaoling Zheng
4 shared publicationsJiaming Tang
College of Life Sciences, Chongqing Normal University, Chongqing, China
2 shared publicationsJiaqi Li
2 shared publicationsLingling Chen
2 shared publicationsSixian Wang
2 shared publications
Latest Publications
- Open Access
- 5 February 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (2) , 103
A Simple and Visual Colorimetric Aptasensor Based on AuNPs for the Rapid Detection of Sulfamethazine in Environmental Samples
Sulfamethazine (SMZ) is widely used in livestock production, and its residues can enter water and soil environments, posing potential risks to human health and ecosystems. This study focuses on environmental samples and constructs an AuNP-based colorimetric aptasensor using the SMZ1S aptamer for the rapid visual detection of SMZ. Under optimized conditions, the aptasensor showed a wide linear range from 0.05 to 0.4 µg/mL and a limit of detection of 0.039 µg/mL. Molecular dynamics simulations have demonstrated that the aptamer’s binding to SMZ is stable, providing a theoretical basis for the high selectivity of the aptasensor. Spike-and-recovery experiments yielded recoveries of 87.3–105.5%, 88.6–102.8%, and 87.5–103.4% for SMZ in lake water, tap water, and soil samples, respectively, with relative standard deviations of 5.9–8.3%, 8.0–10.6%, and 4.8–9.6%, showing good agreement with high-performance liquid chromatography (HPLC) results (R2 ≥ 0.981). Overall, the proposed aptasensor provides a simple and effective approach for rapid detection of SMZ in environmental samples.
- 5 February 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (2) , 103
Open AccessA Simple and Visual Colorimetric Aptasensor Based on AuNPs for the Rapid Detection of Sulfamethazine in Environmental Samples
Sulfamethazine (SMZ) is widely used in livestock production, and its residues can enter water and soil environments, posing potential risks to human health and ecosystems. This study focuses on environmental samples and constructs an AuNP-based colorimetric aptasensor using the SMZ1S aptamer for the rapid visual detection of SMZ. Under optimized conditions, the aptasensor showed a wide linear range from 0.05 to 0.4 µg/mL and a limit of detection of 0.039 µg/mL. Molecular dynamics simulations have demonstrated that the aptamer’s binding to SMZ is stable, providing a theoretical basis for the high selectivity of the aptasensor. Spike-and-recovery experiments yielded recoveries of 87.3–105.5%, 88.6–102.8%, and 87.5–103.4% for SMZ in lake water, tap water, and soil samples, respectively, with relative standard deviations of 5.9–8.3%, 8.0–10.6%, and 4.8–9.6%, showing good agreement with high-performance liquid chromatography (HPLC) results (R2 ≥ 0.981). Overall, the proposed aptasensor provides a simple and effective approach for rapid detection of SMZ in environmental samples.
- Open Access
- 8 January 2025
- Published by MDPI AG in Preprints.org
A Label-Free Aptasensor for the Detection of Sulfaquinoxaline Using AuNPs and Aptamer in Water Environment
Sulfaquinoxaline (SQX) is used extensively in aquaculture and animal husbandry due to its broad antimicrobial spectrum and low cost. However, it is difficult to degrade and there are relevant residues in the aquatic environment, which could be harmful to both the ecological environment and human health. As a new recognition molecule, the aptamer can be recognized with SQX with high affinity and specificity, and the aptamer is no longer adsorbed to AuNPs after binding to SQX, which makes the catalytic effect of AuNPs weakened, an aptasensor for the detection of SQX was successfully constructed. With a linear range of 40-640 ng/mL and a detection limit of 36.95 ng/mL, the aptasensor demonstrated good sensitivity and selectivity. The recoveries of this aptasensor in water samples ranged from 90 to 109.9%, which was quite in line with the high performance liquid chromatography. This indicates that the aptasensor is a useful instrument for detecting SQX in aqueous environmental samples.
- 8 January 2025
- Published by MDPI AG in Preprints.org
Open AccessA Label-Free Aptasensor for the Detection of Sulfaquinoxaline Using AuNPs and Aptamer in Water Environment
Sulfaquinoxaline (SQX) is used extensively in aquaculture and animal husbandry due to its broad antimicrobial spectrum and low cost. However, it is difficult to degrade and there are relevant residues in the aquatic environment, which could be harmful to both the ecological environment and human health. As a new recognition molecule, the aptamer can be recognized with SQX with high affinity and specificity, and the aptamer is no longer adsorbed to AuNPs after binding to SQX, which makes the catalytic effect of AuNPs weakened, an aptasensor for the detection of SQX was successfully constructed. With a linear range of 40-640 ng/mL and a detection limit of 36.95 ng/mL, the aptasensor demonstrated good sensitivity and selectivity. The recoveries of this aptasensor in water samples ranged from 90 to 109.9%, which was quite in line with the high performance liquid chromatography. This indicates that the aptasensor is a useful instrument for detecting SQX in aqueous environmental samples.
- Open Access
- 8 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 30
A Label-Free Aptasensor for the Detection of Sulfaquinoxaline Using AuNPs and Aptamer in Water Environment
Sulfaquinoxaline (SQX) is widely utilized in aquaculture and animal husbandry due to its broad antimicrobial spectrum and low cost. However, it is difficult to degrade, and there are relevant residues in the aquatic environment, which could be harmful to both the ecological environment and human health. As a new recognition molecule, the aptamer can be recognized with SQX with high affinity and specificity, and the aptamer is no longer adsorbed to AuNPs after binding to SQX, which weakens the catalytic effect of AuNPs. Consequently, an aptasensor for the detection of SQX was successfully developed. This aptasensor exhibits a linear range of 40–640 ng/mL, with a detection limit of 36.95 ng/mL, demonstrating both sensitivity and selectivity. The recoveries of this aptasensor in water samples ranged from 90 to 109.9%, which was quite in line with high-performance liquid chromatography. These findings suggest that the aptasensor is a valuable tool for detecting SQX in aqueous environmental samples.
- 8 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 30
Open AccessA Label-Free Aptasensor for the Detection of Sulfaquinoxaline Using AuNPs and Aptamer in Water Environment
Sulfaquinoxaline (SQX) is widely utilized in aquaculture and animal husbandry due to its broad antimicrobial spectrum and low cost. However, it is difficult to degrade, and there are relevant residues in the aquatic environment, which could be harmful to both the ecological environment and human health. As a new recognition molecule, the aptamer can be recognized with SQX with high affinity and specificity, and the aptamer is no longer adsorbed to AuNPs after binding to SQX, which weakens the catalytic effect of AuNPs. Consequently, an aptasensor for the detection of SQX was successfully developed. This aptasensor exhibits a linear range of 40–640 ng/mL, with a detection limit of 36.95 ng/mL, demonstrating both sensitivity and selectivity. The recoveries of this aptasensor in water samples ranged from 90 to 109.9%, which was quite in line with high-performance liquid chromatography. These findings suggest that the aptasensor is a valuable tool for detecting SQX in aqueous environmental samples.
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Screening and Application of a Truncated Aptamer for Highly Sensitive and Selective Detection of 1-Aminohydantoin
The nitrofurantoin metabolite 1-aminohydantoin (AHD) is present in animal-derived foods and can be hazardous to human health. There is an urgent need to develop simple, rapid and effective methods to detect AHD levels in meat and other animal products. In this study, we screened for AHD specific aptamers using magnetic cross-linking precipitation-SELEX (MCP-SELEX), and identified the optimal aptamer through molecular docking. The affinity of the aptamer was further improved by truncation after elucidating its structure and mechanism of action through simulated molecular dynamics (MD). Finally, this optimal aptamer was used to construct a novel fluorescent aptasensor based on graphene oxide (GO) to detect AHD in animal-derived foods. The AHD aptasensor has a broad linear detection range from 0.25 to 150 ng/mL, and a limit of detection (LOD) of 0.2 ng/mL. In addition, the recovery rate of the aptasensor was 89.4% – 110.04%, and the coefficient of variation was lower than 13%. A positive correlation was also observed between this aptasensor and the HPLC (R2 > 0.999). Taken together, we developed a novel aptasensor for detecting AHD in animal-derived foods.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessScreening and Application of a Truncated Aptamer for Highly Sensitive and Selective Detection of 1-Aminohydantoin
The nitrofurantoin metabolite 1-aminohydantoin (AHD) is present in animal-derived foods and can be hazardous to human health. There is an urgent need to develop simple, rapid and effective methods to detect AHD levels in meat and other animal products. In this study, we screened for AHD specific aptamers using magnetic cross-linking precipitation-SELEX (MCP-SELEX), and identified the optimal aptamer through molecular docking. The affinity of the aptamer was further improved by truncation after elucidating its structure and mechanism of action through simulated molecular dynamics (MD). Finally, this optimal aptamer was used to construct a novel fluorescent aptasensor based on graphene oxide (GO) to detect AHD in animal-derived foods. The AHD aptasensor has a broad linear detection range from 0.25 to 150 ng/mL, and a limit of detection (LOD) of 0.2 ng/mL. In addition, the recovery rate of the aptasensor was 89.4% – 110.04%, and the coefficient of variation was lower than 13%. A positive correlation was also observed between this aptasensor and the HPLC (R2 > 0.999). Taken together, we developed a novel aptasensor for detecting AHD in animal-derived foods.
- Open Access
- 21 December 2022
- Published by Frontiers Media SA in Frontiers in Nutrition
- Vol. 9, 1077893
Dual fluorescent aptasensor for simultanous and quantitative detection of sulfadimethoxine and oxytetracycin residues in animal-derived foods tissues based on mesoporous silica
Herein, we developed a dual fluorescent aptasensor based on mesoporous silica to simultaneously detect sulfadimethoxine (SDM) and oxytetracycline (OTC) in animal-derived foods. We immobilized two types of aptamers modified with FAM and CY5 on the silica surface by base complementary pairing reaction with the cDNA modified with a carboxyl group and finally formed the aptasensor detection platform. Under optimal conditions, the detection range of the aptasensor for SDM and OTC was 3–150 ng/mL (R2 = 0.9831) and 5–220 ng/mL (R2 = 0.9884), respectively. The limits of detection for SDM and OTC were 2.2 and 1.23 ng/mL, respectively. The limits of quantification for SDM and OTC were 7.3 and 4.1 ng/mL, respectively. Additionally, the aptasensor was used to analyze spiked samples. The average recovery rates ranged from 91.75 to 114.65% for SDM and 89.66 to 108.94% for OTC, and all coefficients of variation were below 15%. Finally, the performance and practicability of our aptasensor were confirmed by HPLC, demonstrating good consistency. In summary, this study was the first to use the mesoporous silica-mediated fluorescence aptasensor for simultaneous detection of SDM and OTC, offering a new possibility to analyze other antibiotics, biotoxins, and biomolecules.
- 21 December 2022
- Published by Frontiers Media SA in Frontiers in Nutrition
- Vol. 9, 1077893
Open AccessDual fluorescent aptasensor for simultanous and quantitative detection of sulfadimethoxine and oxytetracycin residues in animal-derived foods tissues based on mesoporous silica
Herein, we developed a dual fluorescent aptasensor based on mesoporous silica to simultaneously detect sulfadimethoxine (SDM) and oxytetracycline (OTC) in animal-derived foods. We immobilized two types of aptamers modified with FAM and CY5 on the silica surface by base complementary pairing reaction with the cDNA modified with a carboxyl group and finally formed the aptasensor detection platform. Under optimal conditions, the detection range of the aptasensor for SDM and OTC was 3–150 ng/mL (R2 = 0.9831) and 5–220 ng/mL (R2 = 0.9884), respectively. The limits of detection for SDM and OTC were 2.2 and 1.23 ng/mL, respectively. The limits of quantification for SDM and OTC were 7.3 and 4.1 ng/mL, respectively. Additionally, the aptasensor was used to analyze spiked samples. The average recovery rates ranged from 91.75 to 114.65% for SDM and 89.66 to 108.94% for OTC, and all coefficients of variation were below 15%. Finally, the performance and practicability of our aptasensor were confirmed by HPLC, demonstrating good consistency. In summary, this study was the first to use the mesoporous silica-mediated fluorescence aptasensor for simultaneous detection of SDM and OTC, offering a new possibility to analyze other antibiotics, biotoxins, and biomolecules.
- 20 July 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 10 (32) , 6187-6193
A label-free dual-modal aptasensor for colorimetric and fluorescent detection of sulfadiazine
Sulfadiazine (SDZ) residues in food products and the environment pose a serious threat to human health and ecological balance, thereby warranting the development of new methods for simple, rapid and accurate detection of these compounds. To this end, we developed a novel label-free dual-modal aptasensor for SDZ detection based on distance-dependent color change of gold nanoparticles (AuNPs) and fluorescence resonance energy transfer between AuNPs and rhodamine B (RhoB). In this aptasensor, the binding of the aptamer to SDZ causes unprotected AuNPs to aggregate in NaCl solution, which alters the color of the solution and restores the fluorescence of RhoB. Under optimal conditions, the aptasensor exhibited a linear colorimetric response in the SDZ concentration range of 50–1000 ng mL−1, and a linear fluorescence response in the SDZ concentration range of 4–256 ng mL−1. The limits of detection for colorimetric and fluorescent readings were 28 ng mL−1 and 2 ng mL−1 respectively. The recoveries of SDZ in the spiked real samples were 88.28–108.44% by colorimetry and 90.27–106.04% by fluorometry. Furthermore, the results of this aptasensor showed excellent correlation (R2 ≥ 0.9858) with HPLC findings. Taken together, these experimental results demonstrate that the proposed label-free dual-modal aptasensor can be employed to screen for SDZ contamination in food and environmental samples.
- 20 July 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 10 (32) , 6187-6193
A label-free dual-modal aptasensor for colorimetric and fluorescent detection of sulfadiazine
Sulfadiazine (SDZ) residues in food products and the environment pose a serious threat to human health and ecological balance, thereby warranting the development of new methods for simple, rapid and accurate detection of these compounds. To this end, we developed a novel label-free dual-modal aptasensor for SDZ detection based on distance-dependent color change of gold nanoparticles (AuNPs) and fluorescence resonance energy transfer between AuNPs and rhodamine B (RhoB). In this aptasensor, the binding of the aptamer to SDZ causes unprotected AuNPs to aggregate in NaCl solution, which alters the color of the solution and restores the fluorescence of RhoB. Under optimal conditions, the aptasensor exhibited a linear colorimetric response in the SDZ concentration range of 50–1000 ng mL−1, and a linear fluorescence response in the SDZ concentration range of 4–256 ng mL−1. The limits of detection for colorimetric and fluorescent readings were 28 ng mL−1 and 2 ng mL−1 respectively. The recoveries of SDZ in the spiked real samples were 88.28–108.44% by colorimetry and 90.27–106.04% by fluorometry. Furthermore, the results of this aptasensor showed excellent correlation (R2 ≥ 0.9858) with HPLC findings. Taken together, these experimental results demonstrate that the proposed label-free dual-modal aptasensor can be employed to screen for SDZ contamination in food and environmental samples.