Li Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Li Ji has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Wenlu Song
Guangdong Provincial Engineering Research Center of Oral Orthodontics, Guangzhou, 510080, China
3 shared publicationsZiyang Chen
Guangdong Provincial Engineering Research Center of Oral Orthodontics, Guangzhou, 510080, China
3 shared publications- Bing Guo
Department of Stomatology, the First Affiliated Hospital, Sun Yat-sen University, Guangzhou, 510080, China.
2 shared publications Jiahao Hua
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, 510640, China
2 shared publicationsLongmei Guo
Department of Stomatology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China
2 shared publications- Taicong Chen
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, 510640, China.
2 shared publications
Latest Publications
- Open Access
- 12 June 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Finite element analysis of the nonlinear response of oral mucosa in labial tissue induced by spherical versus square self-ligating brackets
This study employs finite element analysis (FEA) to compare the biomechanical effects of spherical versus square self-ligating brackets on the labial mucosa. Two distinct tooth-bracket-lip models, featuring spherical and square brackets, were developed to simulate labial tissue mechanical responses under various incisor spatial configurations. Each model incorporated five clinical scenarios and employed a hyperelastic Ogden model, a two-stage simulation process (bracket placement followed by orthodontic sliding), and a hierarchical computational framework for localized stress analysis. Nonlinear interactions-including contact, material, and geometric couplings-were rigorously resolved. The stress concentration areas on the labial mucosa are primarily attributed to the clip groove of the spherical bracket and the edge angle of the square bracket, respectively. Under various loading conditions, the maximum stress exerted on the labial mucosa by the spherical bracket consistently remains lower than that induced by the square bracket. Furthermore, compared to the square bracket, the spherical bracket features a smoother surface profile, which significantly reduces mechanical stress on the labial mucosa and achieves a more uniform pressure distribution. Spherical brackets significantly reduce biomechanical stress on the labial mucosa by optimizing surface topography. This advantage may result in a lower incidence of mucosal lesions and improved clinical comfort, supporting their preferential application in orthodontic practice.
- 12 June 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessFinite element analysis of the nonlinear response of oral mucosa in labial tissue induced by spherical versus square self-ligating brackets
This study employs finite element analysis (FEA) to compare the biomechanical effects of spherical versus square self-ligating brackets on the labial mucosa. Two distinct tooth-bracket-lip models, featuring spherical and square brackets, were developed to simulate labial tissue mechanical responses under various incisor spatial configurations. Each model incorporated five clinical scenarios and employed a hyperelastic Ogden model, a two-stage simulation process (bracket placement followed by orthodontic sliding), and a hierarchical computational framework for localized stress analysis. Nonlinear interactions-including contact, material, and geometric couplings-were rigorously resolved. The stress concentration areas on the labial mucosa are primarily attributed to the clip groove of the spherical bracket and the edge angle of the square bracket, respectively. Under various loading conditions, the maximum stress exerted on the labial mucosa by the spherical bracket consistently remains lower than that induced by the square bracket. Furthermore, compared to the square bracket, the spherical bracket features a smoother surface profile, which significantly reduces mechanical stress on the labial mucosa and achieves a more uniform pressure distribution. Spherical brackets significantly reduce biomechanical stress on the labial mucosa by optimizing surface topography. This advantage may result in a lower incidence of mucosal lesions and improved clinical comfort, supporting their preferential application in orthodontic practice.
- 1 February 2026
- Vol. 44 (1) , 48-53
[Comparative study on the clinical performance of concealable traction hook spherical buccal tubes versus conventional rectangular buccal tubes].
This study comprehensively compares the differences between concealable traction hook spherical buccal tubes (concealable spherical tubes) and conventional rectangular buccal tubes in terms of patient comfort, incidence of buccal mucosal injury, periodontal health indices, and clinical bond failure rate to provide evidence for clinical application. Thirty subjects were enrolled and treated using a split-mouth design, where the two sides of each patient's oral cavity were randomly assigned to receive either conventional rectangular buccal tubes (group A) or concealable spherical buccal tubes (group B). During treatment, pain scores, ulcer occurrence, and bond failure of the first molar buccal tubes were recorded. Periodontal indices, including plaque index (PLI), gingival index (GI), and sulcus bleeding index (SBI) of the first molars, were assessed before treatment (T0) and 30 days after tube bonding (T1). The pain scores in group A were significantly higher than those in group B (Z=-5.231, PZ=-4.508, PPPP<0.001). The clinical performance of concealable spherical buccal tubes is significantly superior to that of conventional rectangular buccal tubes in improving patient comfort, reducing the incidence of mucosal injury and clinical bond failure, and maintaining periodontal health. This design offers patients a more comfortable and healthier orthodontic treatment experience.
- 1 February 2026
- Vol. 44 (1) , 48-53
[Comparative study on the clinical performance of concealable traction hook spherical buccal tubes versus conventional rectangular buccal tubes].
This study comprehensively compares the differences between concealable traction hook spherical buccal tubes (concealable spherical tubes) and conventional rectangular buccal tubes in terms of patient comfort, incidence of buccal mucosal injury, periodontal health indices, and clinical bond failure rate to provide evidence for clinical application. Thirty subjects were enrolled and treated using a split-mouth design, where the two sides of each patient's oral cavity were randomly assigned to receive either conventional rectangular buccal tubes (group A) or concealable spherical buccal tubes (group B). During treatment, pain scores, ulcer occurrence, and bond failure of the first molar buccal tubes were recorded. Periodontal indices, including plaque index (PLI), gingival index (GI), and sulcus bleeding index (SBI) of the first molars, were assessed before treatment (T0) and 30 days after tube bonding (T1). The pain scores in group A were significantly higher than those in group B (Z=-5.231, PZ=-4.508, PPPP<0.001). The clinical performance of concealable spherical buccal tubes is significantly superior to that of conventional rectangular buccal tubes in improving patient comfort, reducing the incidence of mucosal injury and clinical bond failure, and maintaining periodontal health. This design offers patients a more comfortable and healthier orthodontic treatment experience.
- Open Access
- 6 January 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Comparative study of torque expression and its biomechanical effects: spherical self-ligating bracket with lock-hook system versus passive self-ligating bracket and conventional bracket
Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression. A maxillary right central incisor, along with its PDL and alveolar bone, were modeled. Three types of brackets were selected: a spherical self-ligating bracket with a lock-hook system, a passive self-ligating bracket (Damon), and a conventional bracket (Discovery). Each bracket was equipped with a 0.022-inch slot and a 0.019 × 0.025-inch stainless steel archwire. A palatal root torque of 20° was applied. The torque moment, as well as the von Mises stress and strain in the PDL, were calculated. A clinical case involving the lingual inclination of the upper anterior teeth was utilized to assess the feasibility of using the spherical self-ligating bracket with the lock-hook system to express torque. At a twist angle of 20°, the maximum torque generated by the spherical self-ligating bracket with a lock-hook system (27.8 N·mm) was approximately 1.6 times greater than that of the Damon bracket (17.5 N·mm) and the Discovery bracket (17.3 N·mm). As the twist angle increased, both the von Mises stress and the strain in the PDL also increased. When the maximum PDL stress was less than 0.026 MPa and the percentage of the PDL good strain area (defined as the area with PDL strain ≥ 0.3%) exceeded 50%, the torque range for the maxillary incisor was between 10.2 and 17.5 N·mm. The clinical case demonstrated that the use of the spherical self-ligating bracket with the lock-hook system effectively corrected the unfavorable linguoclination of the maxillary incisors. The spherical self-ligating bracket with a lock-hook system can significantly enhance torque expression. The optimal torque range for the maxillary incisor is between 10.2 and 17.5 N·mm.
- 6 January 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-12
Open AccessComparative study of torque expression and its biomechanical effects: spherical self-ligating bracket with lock-hook system versus passive self-ligating bracket and conventional bracket
Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression. A maxillary right central incisor, along with its PDL and alveolar bone, were modeled. Three types of brackets were selected: a spherical self-ligating bracket with a lock-hook system, a passive self-ligating bracket (Damon), and a conventional bracket (Discovery). Each bracket was equipped with a 0.022-inch slot and a 0.019 × 0.025-inch stainless steel archwire. A palatal root torque of 20° was applied. The torque moment, as well as the von Mises stress and strain in the PDL, were calculated. A clinical case involving the lingual inclination of the upper anterior teeth was utilized to assess the feasibility of using the spherical self-ligating bracket with the lock-hook system to express torque. At a twist angle of 20°, the maximum torque generated by the spherical self-ligating bracket with a lock-hook system (27.8 N·mm) was approximately 1.6 times greater than that of the Damon bracket (17.5 N·mm) and the Discovery bracket (17.3 N·mm). As the twist angle increased, both the von Mises stress and the strain in the PDL also increased. When the maximum PDL stress was less than 0.026 MPa and the percentage of the PDL good strain area (defined as the area with PDL strain ≥ 0.3%) exceeded 50%, the torque range for the maxillary incisor was between 10.2 and 17.5 N·mm. The clinical case demonstrated that the use of the spherical self-ligating bracket with the lock-hook system effectively corrected the unfavorable linguoclination of the maxillary incisors. The spherical self-ligating bracket with a lock-hook system can significantly enhance torque expression. The optimal torque range for the maxillary incisor is between 10.2 and 17.5 N·mm.