Xiaobo Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaobo Hu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Jing Quan
Shanghai Center for Clinical Laboratory
2 shared publicationsPengyin Zhang
Shanghai Center for Clinical Laboratory
2 shared publicationsXue Yang
Shanghai Center for Clinical Laboratory
2 shared publications- Yanqun Xiao
Shanghai Center for Clinical Laboratory, 528 Hongshan Road, Shanghai 200126, China
2 shared publications Yun Bao
Shanghai Centre for Clinical Laboratory, 528 Hongshan Road, Shanghai, 200126, PR China
2 shared publications- Yun Bao
Shanghai Center for Clinical Laboratory
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (11) , e0362593
External quality assessment of genetic testing for Glucose-6-phosphate dehydrogenase deficiency in Shanghai and other regions
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most prevalent enzymatic disorder of red blood cells. Early identification of at‑risk individuals through genetic testing facilitates the implementation of targeted preventive measures to reduce disease burden. However, the accuracy and reliability of molecular testing across clinical laboratories have not been systematically established. This pioneering study assessed current laboratory performance in analyzing and reporting G6PD -related variants through an annual external quality assessment (EQA) program. A panel of five dried blood spots (DBS) mimicking samples was prepared from distinct cell lines and distributed to participants. The sample panel contained four positive samples carrying G6PD pathogenic variants, including hemizygous, heterozygous, and compound heterozygous genotypes, and one negative sample. Of 23 participating laboratories, only 14 (60.87%) achieved full marks. Although all participants successfully detected pathogenic mutations, 49 variant reporting errors were identified and categorized into four types. Most laboratories yielded satisfactory results; however, improvements are needed in variant description and result reporting. These findings highlight the necessity of continued education on international reporting standards and robust quality assurance to ensure accurate, consistent genetic variants interpretation across laboratories.
- 16 November 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (11) , e0362593
Open AccessExternal quality assessment of genetic testing for Glucose-6-phosphate dehydrogenase deficiency in Shanghai and other regions
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most prevalent enzymatic disorder of red blood cells. Early identification of at‑risk individuals through genetic testing facilitates the implementation of targeted preventive measures to reduce disease burden. However, the accuracy and reliability of molecular testing across clinical laboratories have not been systematically established. This pioneering study assessed current laboratory performance in analyzing and reporting G6PD -related variants through an annual external quality assessment (EQA) program. A panel of five dried blood spots (DBS) mimicking samples was prepared from distinct cell lines and distributed to participants. The sample panel contained four positive samples carrying G6PD pathogenic variants, including hemizygous, heterozygous, and compound heterozygous genotypes, and one negative sample. Of 23 participating laboratories, only 14 (60.87%) achieved full marks. Although all participants successfully detected pathogenic mutations, 49 variant reporting errors were identified and categorized into four types. Most laboratories yielded satisfactory results; however, improvements are needed in variant description and result reporting. These findings highlight the necessity of continued education on international reporting standards and robust quality assurance to ensure accurate, consistent genetic variants interpretation across laboratories.
- Open Access
- 27 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (7) , 1005
External Quality Assessment of Molecular Testing for HLA-B*58:01 Allele in Shanghai
Background/Objectives: Allopurinol, a first-line drug for gout and hyperuricemia, carries a risk of severe cutaneous adverse reactions (SCARs). Studies have established a strong association between HLA-B*58:01 and this adverse reaction. Although pre-treatment genotyping is recommended, the reliability of HLA-B*58:01 genetic testing varies across laboratories. This study aims to assess the performance of HLA-B*58:01 genetic testing of clinical laboratories in Shanghai through an External Quality Assessment (EQA) program, evaluating accuracy and standardization. Methods: The EQA program was carried out twice a year in 2023 and 2024. Each EQA sample panel consisted of five distinct samples, including HLA-B*58:01 allele-positive and -negative cell cultures. Sample panels were distributed to clinical laboratories through the cold chain system and results were analyzed and scored. Results: EQA samples used in this study were optimized for evaluating current HLA-B*58:01 genotyping assays, and the EQA samples were proved to be homogeneous and stable through each EQA period. In 2023, 17 and 16 clinical laboratories participated in the two EQA schemes; in 2024, 34 and 33 laboratories participated. A total of 14/17 (82.4%), 16/16 (100%), 33/34 (97.1%), and 33/33 (100%) laboratories achieved “optimal” scores. Conclusions: EQA results indicate that most of clinical laboratories in Shanghai exhibit constantly satisfactory performance for HLA-B*58:01 genotyping. However, a few laboratories still need further improvement. Additionally, EQA has demonstrated to be an important method for monitoring clinical laboratories’ performance.
- 27 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (7) , 1005
Open AccessExternal Quality Assessment of Molecular Testing for HLA-B*58:01 Allele in Shanghai
Background/Objectives: Allopurinol, a first-line drug for gout and hyperuricemia, carries a risk of severe cutaneous adverse reactions (SCARs). Studies have established a strong association between HLA-B*58:01 and this adverse reaction. Although pre-treatment genotyping is recommended, the reliability of HLA-B*58:01 genetic testing varies across laboratories. This study aims to assess the performance of HLA-B*58:01 genetic testing of clinical laboratories in Shanghai through an External Quality Assessment (EQA) program, evaluating accuracy and standardization. Methods: The EQA program was carried out twice a year in 2023 and 2024. Each EQA sample panel consisted of five distinct samples, including HLA-B*58:01 allele-positive and -negative cell cultures. Sample panels were distributed to clinical laboratories through the cold chain system and results were analyzed and scored. Results: EQA samples used in this study were optimized for evaluating current HLA-B*58:01 genotyping assays, and the EQA samples were proved to be homogeneous and stable through each EQA period. In 2023, 17 and 16 clinical laboratories participated in the two EQA schemes; in 2024, 34 and 33 laboratories participated. A total of 14/17 (82.4%), 16/16 (100%), 33/34 (97.1%), and 33/33 (100%) laboratories achieved “optimal” scores. Conclusions: EQA results indicate that most of clinical laboratories in Shanghai exhibit constantly satisfactory performance for HLA-B*58:01 genotyping. However, a few laboratories still need further improvement. Additionally, EQA has demonstrated to be an important method for monitoring clinical laboratories’ performance.
- Open Access
- 2 July 2025
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 46, e00488
External quality assessment of genetic testing for hereditary hearing loss in Shanghai and other regions
- 2 July 2025
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 46, e00488
Open AccessExternal quality assessment of genetic testing for hereditary hearing loss in Shanghai and other regions
- 10 January 2025
- Vol. 42 (1) , 1-11
[Expert consensus on the standardized application of whole exome sequencing technology in diagnosis of genetic disorders].
Next generation sequencing (NGS) technology is playing an increasingly important role in the diagnosis of genetic diseases. Whole exome sequencing (WES) which targets the coding regions of the genome has been widely used in the diagnosis of genetic diseases for its low cost and high efficiency. However, compared to conventional methods, the NGS process is intricate, and there is variability in the expertise of data analysts and variant interpreters, which may lead to inconsistencies in the outcomes. To ensure the quality of testing and enhance the diagnostic rate of diseases, this consensus has provided recommendations regarding the laboratory setup, operational procedures, data analysis, result interpretation, and quality control for WES, with an aim to standardize its application in the detection of genetic disorders.
- 10 January 2025
- Vol. 42 (1) , 1-11
[Expert consensus on the standardized application of whole exome sequencing technology in diagnosis of genetic disorders].
Next generation sequencing (NGS) technology is playing an increasingly important role in the diagnosis of genetic diseases. Whole exome sequencing (WES) which targets the coding regions of the genome has been widely used in the diagnosis of genetic diseases for its low cost and high efficiency. However, compared to conventional methods, the NGS process is intricate, and there is variability in the expertise of data analysts and variant interpreters, which may lead to inconsistencies in the outcomes. To ensure the quality of testing and enhance the diagnostic rate of diseases, this consensus has provided recommendations regarding the laboratory setup, operational procedures, data analysis, result interpretation, and quality control for WES, with an aim to standardize its application in the detection of genetic disorders.