SLShudong Li

Shudong Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shudong Li has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MPicker: visualizing and picking membrane proteins for cryo-electron tomography

    by Xiaofeng Yan, Shudong Li, Weilin Huang, Hao Wang, Tianfang Zhao, Mingtao Huang, Niyun Zhou, Yuan Shen, Xueming Li

    Advancements in cryo-electron tomography (cryoET) allow the structure of macromolecules to be determined in situ, which is crucial for studying membrane protein structures and their interactions in the cellular environment. However, membranes are often highly curved and have a strong contrast in cryoET tomograms, which masks the signals from membrane proteins. These factors pose difficulties in observing and revealing the structures of membrane proteins in situ. Here, we report a membrane-flattening method and the corresponding software, MPicker, designed for the visualization, localization, and orientation determination of membrane proteins in cryoET tomograms. This method improves the visualization of proteins on and around membranes by generating a flattened tomogram that eliminates membrane curvature and reduces the spatial complexity of membrane protein analysis. In MPicker, we integrated approaches for automated particle picking and coarse alignment of membrane proteins for sub-tomogram averaging. MPicker was tested on tomograms of various cells to evaluate the method for visualizing, picking, and analyzing membrane proteins.


  • Open Access

    Strategies for CT Reconstruction using Diffusion Posterior Sampling with a Nonlinear Model

    by Xiao Jiang, Shudong Li, Peiqing Teng, Grace Gang, J. Webster Stayman

    Diffusion Posterior Sampling(DPS) methodology is a novel framework that permits nonlinear CT reconstruction by integrating a diffusion prior and an analytic physical system model, allowing for one-time training for different applications. However, baseline DPS can struggle with large variability, hallucinations, and slow reconstruction. This work introduces a number of strategies designed to enhance the stability and efficiency of DPS CT reconstruction. Specifically, jumpstart sampling allows one to skip many reverse time steps, significantly reducing the reconstruction time as well as the sampling variability. Additionally, the likelihood update is modified to simplify the Jacobian computation and improve data consistency more efficiently. Finally, a hyperparameter sweep is conducted to investigate the effects of parameter tuning and to optimize the overall reconstruction performance. Simulation studies demonstrated that the proposed DPS technique achieves up to 46.72% PSNR and 51.50% SSIM enhancement in a low-mAs setting, and an over 31.43% variability reduction in a sparse-view setting. Moreover, reconstruction time is sped up from >23.5 s/slice to <1.5 s/slice. In a physical data study, the proposed DPS exhibits robustness on an anthropomorphic phantom reconstruction which does not strictly follow the prior distribution. Quantitative analysis demonstrates that the proposed DPS can accommodate various dose levels and number of views. With 10% dose, only a 5.60% and 4.84% reduction of PSNR and SSIM was observed for the proposed approach. Both simulation and phantom studies demonstrate that the proposed method can significantly improve reconstruction accuracy and reduce computational costs, greatly enhancing the practicality of DPS CT reconstruction.

  • CT reconstruction using diffusion posterior sampling conditioned on a nonlinear measurement model

    by Shudong Li, Xiao Jiang, Matthew Tivnan, Grace J. Gang, Yuan Shen, J. Webster Stayman

    PurposeRecently, diffusion posterior sampling (DPS), where score-based diffusion priors are combined with likelihood models, has been used to produce high-quality computed tomography (CT) images given low-quality measurements. This technique permits one-time, unsupervised training of a CT prior, which can then be incorporated with an arbitrary data model. However, current methods rely on a linear model of X-ray CT physics to reconstruct. Although it is common to linearize the transmission tomography reconstruction problem, this is an approximation to the true and inherently nonlinear forward model. We propose a DPS method that integrates a general nonlinear measurement model.ApproachWe implement a traditional unconditional diffusion model by training a prior score function estimator and apply Bayes’ rule to combine this prior with a measurement likelihood score function derived from the nonlinear physical model to arrive at a posterior score function that can be used to sample the reverse-time diffusion process. We develop computational enhancements for the approach and evaluate the reconstruction approach in several simulation studies.ResultsThe proposed nonlinear DPS provides improved performance over traditional reconstruction methods and DPS with a linear model. Moreover, as compared with a conditionally trained deep learning approach, the nonlinear DPS approach shows a better ability to provide high-quality images for different acquisition protocols.ConclusionThis plug-and-play method allows the incorporation of a diffusion-based prior with a general nonlinear CT measurement model. This permits the application of the approach to different systems, protocols, etc., without the need for any additional training.