Mustafa Haider
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mustafa Haider has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Aaron So
Imaging Program, Lawson Research Institute, London, ON N6A 4V2, Canada
2 shared publications Akshaye Goela
Medical Biophysics, Schulich School of Medicine and Dentistry, Western University , London, ON N6A 5C1
1 shared publication- Christian Rogers
Department of Medical Biophysics, Western University, London, ON N6A 5C1, Canada
1 shared publication - Ji Won Lee
Department of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.
1 shared publication - Kakuya Kitagawa
Department of Radiology, Mie University Hospital, Tsu 514-8507, Japan
1 shared publication - Ki Seok Choo
Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (15) , 2408
Fractional Flow Reserve Measurement Using Dynamic CT Perfusion Imaging in Patients with Heavy Coronary Calcification and Stent
Background/Objectives: A novel CT dynamic angiographic imaging (CT-DAI) analytic algorithm was evaluated against the clinical gold standard for fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD) characterized by diffuse dense calcification and previous stent implantation. Methods: This retrospective feasibility study included 24 coronary arteries in 16 patients (age 69.9 ± 8.9 years, 11 males) with CAD who underwent dynamic CT myocardial perfusion scanning using a dual-source CT scanner after intravenous infusion of adenosine triphosphate. The included patients had analyzable proximal and distal coronary artery segments adjacent to the stenosis in the myocardial perfusion images and had corresponding invasive catheter-based FFR measurements for that stenosis. An in-house software based on the CT-DAI algorithm was used to compute FFR using the coronary time-enhancement curves sampled across the stenosis from stress myocardial CT perfusion images. The CT-DAI derived FFR values were then compared to the corresponding catheter-based FFR values. A coronary stenosis was considered functionally significant for FFR values below 0.8. Results: The mean axial length and calcium score of the coronary stenoses were 47.9 mm and 1911.63 Agatston Units, respectively. Eight coronary arteries received stents from previous treatments. The CT-DAI derived FFR values (0.822 ± 0.143) showed an excellent linear correlation (R = 0.974) with and were indifferent from the invasive FFR values (0.826 ± 0.147, p = 0.537), resulting in 100% per-vessel and per-patient sensitivity and specificity for the detection of functionally significant coronary stenosis. Bland–Altman analysis revealed a minimal mean difference in FFR measurements (0.004) between the two modalities with the lower and upper limits of agreement at −0.061 and 0.069, respectively. Conclusions: The findings suggest that CT-DAI can derive FFR for the coronary arteries with heavy calcification and stents from dynamic myocardial CT perfusion images.
- 31 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (15) , 2408
Open AccessFractional Flow Reserve Measurement Using Dynamic CT Perfusion Imaging in Patients with Heavy Coronary Calcification and Stent
Background/Objectives: A novel CT dynamic angiographic imaging (CT-DAI) analytic algorithm was evaluated against the clinical gold standard for fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD) characterized by diffuse dense calcification and previous stent implantation. Methods: This retrospective feasibility study included 24 coronary arteries in 16 patients (age 69.9 ± 8.9 years, 11 males) with CAD who underwent dynamic CT myocardial perfusion scanning using a dual-source CT scanner after intravenous infusion of adenosine triphosphate. The included patients had analyzable proximal and distal coronary artery segments adjacent to the stenosis in the myocardial perfusion images and had corresponding invasive catheter-based FFR measurements for that stenosis. An in-house software based on the CT-DAI algorithm was used to compute FFR using the coronary time-enhancement curves sampled across the stenosis from stress myocardial CT perfusion images. The CT-DAI derived FFR values were then compared to the corresponding catheter-based FFR values. A coronary stenosis was considered functionally significant for FFR values below 0.8. Results: The mean axial length and calcium score of the coronary stenoses were 47.9 mm and 1911.63 Agatston Units, respectively. Eight coronary arteries received stents from previous treatments. The CT-DAI derived FFR values (0.822 ± 0.143) showed an excellent linear correlation (R = 0.974) with and were indifferent from the invasive FFR values (0.826 ± 0.147, p = 0.537), resulting in 100% per-vessel and per-patient sensitivity and specificity for the detection of functionally significant coronary stenosis. Bland–Altman analysis revealed a minimal mean difference in FFR measurements (0.004) between the two modalities with the lower and upper limits of agreement at −0.061 and 0.069, respectively. Conclusions: The findings suggest that CT-DAI can derive FFR for the coronary arteries with heavy calcification and stents from dynamic myocardial CT perfusion images.
- Open Access
- 1 October 2024
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 1 (4) , umae031
Fractional flow reserve measurement using dynamic CT perfusion imaging in patients with coronary artery disease
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD). Materials and Methods: This retrospective study included 14 patients (age 58.5 ± 10.6 years, 11 males) with CAD who underwent stress dynamic CT myocardial perfusion scanning with a dual-source CT scanner. The included patients had analyzable proximal and distal coronary artery segments adjacent to the stenosis in the perfusion images and had corresponding invasive catheter-based FFR measurements for that stenosis. An in-house software based on the CT-DAI algorithm was used to compute FFR using the pre- and post- lesion coronary time-enhancement curves obtained from the stress myocardial perfusion images. The CT-DAI derived FFR values were then compared to the corresponding catheter-based invasive FFR values. A coronary artery stenosis was considered functionally significant for FFR value <0.8. Results: The CT-DAI derived FFR values were in agreement with the invasive FFR values in all 15 coronary arteries in 14 patients, resulting in 100% per-vessel and per-patient diagnostic accuracy. FFR derived using CT-DAI (M = 0.768, SD = 0.156) showed an excellent linear correlation (R = 0.910, P < .001) and statistical indifference (P= .655) with that measured using invasive catheter-based method (M = 0.796, SD = 0.149). Bland-Altman analysis showed no significant proportional bias. Conclusion: The novel CT-DAI algorithm can reliably compute FFR across a coronary artery stenosis directly from dynamic CT myocardial perfusion images, facilitating rapid on-site hemodynamic assessment of the epicardial coronary artery stenosis in patients with CAD.
- 1 October 2024
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 1 (4) , umae031
Open AccessFractional flow reserve measurement using dynamic CT perfusion imaging in patients with coronary artery disease
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD). Materials and Methods: This retrospective study included 14 patients (age 58.5 ± 10.6 years, 11 males) with CAD who underwent stress dynamic CT myocardial perfusion scanning with a dual-source CT scanner. The included patients had analyzable proximal and distal coronary artery segments adjacent to the stenosis in the perfusion images and had corresponding invasive catheter-based FFR measurements for that stenosis. An in-house software based on the CT-DAI algorithm was used to compute FFR using the pre- and post- lesion coronary time-enhancement curves obtained from the stress myocardial perfusion images. The CT-DAI derived FFR values were then compared to the corresponding catheter-based invasive FFR values. A coronary artery stenosis was considered functionally significant for FFR value <0.8. Results: The CT-DAI derived FFR values were in agreement with the invasive FFR values in all 15 coronary arteries in 14 patients, resulting in 100% per-vessel and per-patient diagnostic accuracy. FFR derived using CT-DAI (M = 0.768, SD = 0.156) showed an excellent linear correlation (R = 0.910, P < .001) and statistical indifference (P= .655) with that measured using invasive catheter-based method (M = 0.796, SD = 0.149). Bland-Altman analysis showed no significant proportional bias. Conclusion: The novel CT-DAI algorithm can reliably compute FFR across a coronary artery stenosis directly from dynamic CT myocardial perfusion images, facilitating rapid on-site hemodynamic assessment of the epicardial coronary artery stenosis in patients with CAD.