Ekrem Sağtaş
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ekrem Sağtaş has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Sedat Kaygusuz
KIRIKKALE ÜNİVERSİTESİ, TIP FAKÜLTESİ
2 shared publications - Ahmet İrGin
National HPV Laboratory, Department of National Reference Laboratories and Biological Products, Public Health General Directorate, Ministry of Health, Ankara, Turkey
1 shared publication - Biran Musul
World Health Organization Country Office in Türkiye, Ankara, Türkiye
1 shared publication - Ege Dedeoğlu
World Health Organization Country Office in Türkiye, Ankara, Türkiye
1 shared publication - Fatih Çubuk
Department of Medical Microbiology, Sivas State Hospital, Sivas, Türkiye
1 shared publication - Fikrican Balcı
Pharmaline Sağlık Hizmetleri San. Tic. A.Ş, Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
- 10 July 2025
- Published by Microbiology Society in Microbial Genomics
- Vol. 11 (7) , 001357
Enhancing public health surveillance: a comparative study of platform-specific and hybrid assembly approaches in SARS-CoV-2 genome sequencing
During the COVID-19 pandemic, next-generation sequencing (NGS) has been instrumental for public health laboratories in tracking severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) mutations and informing responses. Illumina systems and Oxford Nanopore Technologies (ONT) have been primary tools for NGS, each presenting unique advantages. The hybrid assembly (HA) approach, integrating short- and long-read sequencing methods, has been developed to improve genome accuracy by utilizing the combined advantages of both techniques. While HA has been used to enhance SARS-CoV-2 genome quality, its optimal applications for SARS-CoV-2 sequencing and surveillance have not been systematically studied. This study seeks to address this gap by evaluating the conditions under which HA improves SARS-CoV-2 genomic surveillance, analysing 192 samples using eight bioinformatics methods across both platforms. HA was evaluated against single-technology approaches for its genome assembly and mutation detection performance. While HA did not outperform single-technology methods in detecting unique mutations, it produced marginally more complete genomes than Illumina-based methods. Importantly, mutations identified by HA were consistently detected across all eight methodologies, demonstrating its reliability in mutation detection. Moreover, our research underlines the critical need for in-house validation of methods and exposes the limitations inherent in proprietary pipelines. Our findings suggest that an HA approach could be used as a quality control tool in genomic surveillance, particularly for improving low-quality ONT sequencing data by integrating high-quality Illumina sequencing data. However, implementing HA demands the presence of both sequencing platforms and additional resources, such as hands-on time, expensive sequencing reagents and bioinformatics know-how. A decision-tree analysis identified the percentage of trimmed ONT reads relative to total reads as crucial for HA success, emphasizing the significance of high-quality ONT reads. This comprehensive approach provides public health laboratories insights to refine genomic surveillance strategies for SARS-CoV-2, potentially influencing future research and response efforts.
- 10 July 2025
- Published by Microbiology Society in Microbial Genomics
- Vol. 11 (7) , 001357
Open AccessEnhancing public health surveillance: a comparative study of platform-specific and hybrid assembly approaches in SARS-CoV-2 genome sequencing
During the COVID-19 pandemic, next-generation sequencing (NGS) has been instrumental for public health laboratories in tracking severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) mutations and informing responses. Illumina systems and Oxford Nanopore Technologies (ONT) have been primary tools for NGS, each presenting unique advantages. The hybrid assembly (HA) approach, integrating short- and long-read sequencing methods, has been developed to improve genome accuracy by utilizing the combined advantages of both techniques. While HA has been used to enhance SARS-CoV-2 genome quality, its optimal applications for SARS-CoV-2 sequencing and surveillance have not been systematically studied. This study seeks to address this gap by evaluating the conditions under which HA improves SARS-CoV-2 genomic surveillance, analysing 192 samples using eight bioinformatics methods across both platforms. HA was evaluated against single-technology approaches for its genome assembly and mutation detection performance. While HA did not outperform single-technology methods in detecting unique mutations, it produced marginally more complete genomes than Illumina-based methods. Importantly, mutations identified by HA were consistently detected across all eight methodologies, demonstrating its reliability in mutation detection. Moreover, our research underlines the critical need for in-house validation of methods and exposes the limitations inherent in proprietary pipelines. Our findings suggest that an HA approach could be used as a quality control tool in genomic surveillance, particularly for improving low-quality ONT sequencing data by integrating high-quality Illumina sequencing data. However, implementing HA demands the presence of both sequencing platforms and additional resources, such as hands-on time, expensive sequencing reagents and bioinformatics know-how. A decision-tree analysis identified the percentage of trimmed ONT reads relative to total reads as crucial for HA success, emphasizing the significance of high-quality ONT reads. This comprehensive approach provides public health laboratories insights to refine genomic surveillance strategies for SARS-CoV-2, potentially influencing future research and response efforts.
- Open Access
- 11 January 2025
- Published by Springer Nature in Virology Journal
- Vol. 22 (1) , 1-7
A new approach for detecting HPV DNA in cervical swabs: comparison of nucleic acid extraction with direct PCR
Almost all cases of cervical cancer are associated with persistent high-risk HPV infection. WHO prioritizes primary HPV testing for cervical cancer screening. Cervical cancer screening programs require the ability to process a large number of samples in a simple and standardized manner and obtain reliable results. The workload, time, and cost associated with the number of samples to be processed encourage the development of alternative methods to the traditional nucleic acid extraction method for population-based screening. In this study, we aimed to compare the performance of a commercial pre-denaturation solution with nucleic acid extraction in HPV DNA detection by PCR in cervical swab samples. The study was designed in two phases: an experimental phase and a clinical phase. A total of 1200 cervical swabs were included in the clinical phase of the study. Positive results were obtained in 143 (11.9%) samples by nucleic acid extraction and 137 (11.4%) samples by PharmaDirect. Discordant results were detected in 28 (2.3%) samples. PharmaDirect provided 88.1% sensitivity compared to nucleic acid extraction. PharmaDirect provided high sensitivity for HPV genotype 16 (92.3%) and relatively limited sensitivity for mixed genotype infections (73.7%). This study demonstrates the potential of an alternative commercial pre-denaturation product that does not require nucleic acid extraction for HPV DNA detection in cervical swab samples. Such approaches may represent a useful alternative for population-based screening studies. Not applicable.
- 11 January 2025
- Published by Springer Nature in Virology Journal
- Vol. 22 (1) , 1-7
Open AccessA new approach for detecting HPV DNA in cervical swabs: comparison of nucleic acid extraction with direct PCR
Almost all cases of cervical cancer are associated with persistent high-risk HPV infection. WHO prioritizes primary HPV testing for cervical cancer screening. Cervical cancer screening programs require the ability to process a large number of samples in a simple and standardized manner and obtain reliable results. The workload, time, and cost associated with the number of samples to be processed encourage the development of alternative methods to the traditional nucleic acid extraction method for population-based screening. In this study, we aimed to compare the performance of a commercial pre-denaturation solution with nucleic acid extraction in HPV DNA detection by PCR in cervical swab samples. The study was designed in two phases: an experimental phase and a clinical phase. A total of 1200 cervical swabs were included in the clinical phase of the study. Positive results were obtained in 143 (11.9%) samples by nucleic acid extraction and 137 (11.4%) samples by PharmaDirect. Discordant results were detected in 28 (2.3%) samples. PharmaDirect provided 88.1% sensitivity compared to nucleic acid extraction. PharmaDirect provided high sensitivity for HPV genotype 16 (92.3%) and relatively limited sensitivity for mixed genotype infections (73.7%). This study demonstrates the potential of an alternative commercial pre-denaturation product that does not require nucleic acid extraction for HPV DNA detection in cervical swab samples. Such approaches may represent a useful alternative for population-based screening studies. Not applicable.