Arif Mulyanto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Arif Mulyanto has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Farida Dwi Handayani
National Innovation Research Agency (BRIN), Indonesia, Indonesia
2 shared publications - Kurnia Ritma Dhanti
Department of Medical Laboratory Technology, Faculty of Health Science, Universitas Muhammadiyah Purwokerto, Purwokerto, Indonesia, Indonesia
2 shared publications - Budi Prasetyo
Medical Laboratory Technology D4 Study Program, Faculty of Health Sciences, Universitas Muhammadiyah Purwokerto, Banyumas, Indonesia, Indonesia
1 shared publication - Deliza Dhiakhalda Sarinastiti
Department of Medical Laboratory Technology, Faculty of Health Science, Universitas Muhammadiyah Purwokerto, Purwokerto, Indonesia, Indonesia
1 shared publication - Dita Pratiwi Kusuma Wardani
Universitas Muhammadiyah Purwokerto
1 shared publication Fitri Paramitha Annisa
Department of Medical laboratory Technology, Faculty of Health Science, Universitas Muhammadiyah Purwokerto
1 shared publication
Latest Publications
- Open Access
- 10 January 2025
- Published by Poltekkes Kemenkes Yogyakarta in Jurnal Teknologi Laboratorium
- Vol. 14 (1) , 60-72
Evaluating the synergistic antibacterial and anti-inflammatory effects of Kapok banana peel (Musa acuminata balbisiana colla) and Bay leaf (Syzygium polyanthum) extract gel formulation on wound healing
The body's natural healing mechanisms rely significantly on substances that enhance tissue regeneration. Rapid growth of new skin cells can considerably accelerate wound healing. This study investigates the effectiveness of gel formulations derived from Saba banana peel (Musa acuminata balbisiana Colla) and bay leaf (Syzygium polyanthum) extracts as anti-inflammatory and antiseptic agents. Utilizing a true-experimental posttest-only control group design, we evaluated three different gel formulations: F1 (25% banana peel extract : 75% bay leaf extract), F2 (50% banana peel extract : 50% bay leaf extract), and F3 (75% banana peel extract : 25% bay leaf extract). Twenty white rats (Rattus norvegicus) were divided into five groups, each subjected to standardized incision wounds. Treatments were administered three times daily over a seven-day observation period, with wound healing assessed by measuring incision length. Formulation F1 demonstrated notable antibacterial efficacy against Staphylococcus aureus. Conversely, formulation F3 (75% banana peel : 25% bay leaf) exhibited superior wound healing performance, achieving an average healing rate of 42.97%, surpassing the positive control group. These findings indicate that gels containing extracts of Saba banana peel and bay leaf possess significant antibacterial activity against S. aureus and effectively enhance wound healing in animal models.
- 10 January 2025
- Published by Poltekkes Kemenkes Yogyakarta in Jurnal Teknologi Laboratorium
- Vol. 14 (1) , 60-72
Open AccessEvaluating the synergistic antibacterial and anti-inflammatory effects of Kapok banana peel (Musa acuminata balbisiana colla) and Bay leaf (Syzygium polyanthum) extract gel formulation on wound healing
The body's natural healing mechanisms rely significantly on substances that enhance tissue regeneration. Rapid growth of new skin cells can considerably accelerate wound healing. This study investigates the effectiveness of gel formulations derived from Saba banana peel (Musa acuminata balbisiana Colla) and bay leaf (Syzygium polyanthum) extracts as anti-inflammatory and antiseptic agents. Utilizing a true-experimental posttest-only control group design, we evaluated three different gel formulations: F1 (25% banana peel extract : 75% bay leaf extract), F2 (50% banana peel extract : 50% bay leaf extract), and F3 (75% banana peel extract : 25% bay leaf extract). Twenty white rats (Rattus norvegicus) were divided into five groups, each subjected to standardized incision wounds. Treatments were administered three times daily over a seven-day observation period, with wound healing assessed by measuring incision length. Formulation F1 demonstrated notable antibacterial efficacy against Staphylococcus aureus. Conversely, formulation F3 (75% banana peel : 25% bay leaf) exhibited superior wound healing performance, achieving an average healing rate of 42.97%, surpassing the positive control group. These findings indicate that gels containing extracts of Saba banana peel and bay leaf possess significant antibacterial activity against S. aureus and effectively enhance wound healing in animal models.
- Open Access
- 26 August 2024
- Published by Poltekkes Kemenkes Yogyakarta in Jurnal Teknologi Laboratorium
- Vol. 13 (2) , 186-197
Effect of different speed and time of centrifugations on decontamination of Leptospira spp. cultures from rat’s kidney
The centrifugal force in the centrifuge is able to change the surface properties of bacterial cells and the inner structure, including DNA, so that it can damage bacterial cells. The pathogenic bacterium Leptospira spp is a zoonosis that lives in the kidneys of rats as a natural reservoir, but breeding it is still a challenge because it can be contaminated with other bacteria. Decontamination methods are needed to obtain clean and pure Leptospira spp cultures for further examination and epidemiology. This study aims to obtain an appropriate decontamination method for the sustainability of Leptospira spp cultures in the laboratory using a combination of centrifugation speeds. Leptospira spp cultures were obtained from leptospirosis endemic areas in Central Java Province, Demak Regency, Gebang Village and Tridonorejo as many as 13 Leptospira spp cultures contaminated with cocci, coma, and filaments. Cultures were observed at 20x magnification under a dark field microscope at 8 weeks old. Contaminated cultures were centrifuged at 3000, 6000, and 8000 rpm for 5 and 10 minutes, then recultured into new media. The media used in this study were EMJH + STAFF and V5FU media. The results showed that rat kidney cultures showed 7 and 6 positives from the Gebang and Tridonorejo areas. Data on the results of bacterial decontamination obtained at a speed of 3000 rpm for 5 minutes has a greater percentage than the speed of 6000 and 8000 rpm with a result of 30.8%. This is in the process of purifying Leptospira spp using centrifugation proven to remove contaminant bacteria such as cocci, coma, and filaments. This is because centrifugation speed is able to change the nature of the surface structure and interior of bacterial cells, including DNA, so that it can damage bacterial cells.
- 26 August 2024
- Published by Poltekkes Kemenkes Yogyakarta in Jurnal Teknologi Laboratorium
- Vol. 13 (2) , 186-197
Open AccessEffect of different speed and time of centrifugations on decontamination of Leptospira spp. cultures from rat’s kidney
The centrifugal force in the centrifuge is able to change the surface properties of bacterial cells and the inner structure, including DNA, so that it can damage bacterial cells. The pathogenic bacterium Leptospira spp is a zoonosis that lives in the kidneys of rats as a natural reservoir, but breeding it is still a challenge because it can be contaminated with other bacteria. Decontamination methods are needed to obtain clean and pure Leptospira spp cultures for further examination and epidemiology. This study aims to obtain an appropriate decontamination method for the sustainability of Leptospira spp cultures in the laboratory using a combination of centrifugation speeds. Leptospira spp cultures were obtained from leptospirosis endemic areas in Central Java Province, Demak Regency, Gebang Village and Tridonorejo as many as 13 Leptospira spp cultures contaminated with cocci, coma, and filaments. Cultures were observed at 20x magnification under a dark field microscope at 8 weeks old. Contaminated cultures were centrifuged at 3000, 6000, and 8000 rpm for 5 and 10 minutes, then recultured into new media. The media used in this study were EMJH + STAFF and V5FU media. The results showed that rat kidney cultures showed 7 and 6 positives from the Gebang and Tridonorejo areas. Data on the results of bacterial decontamination obtained at a speed of 3000 rpm for 5 minutes has a greater percentage than the speed of 6000 and 8000 rpm with a result of 30.8%. This is in the process of purifying Leptospira spp using centrifugation proven to remove contaminant bacteria such as cocci, coma, and filaments. This is because centrifugation speed is able to change the nature of the surface structure and interior of bacterial cells, including DNA, so that it can damage bacterial cells.
- Open Access
- 26 August 2024
- Published by Poltekkes Kemenkes Yogyakarta in Jurnal Teknologi Laboratorium
- Vol. 13 (2) , 156-165
Optimizing DNA extraction methods for enhanced detection of pathogenic Leptospira spp. in cultures using PCR
Leptospirosis is a worldwide zoonosis caused by Leptospira interrogans. Laboratory diagnosis of leptospirosis can be done through sample culture. However, microscopic observation of positive Leptospira spp. culture need to be supported by molecular detection to confirm the presence of pathogenic Leptospira spp. This study aimed to compare the effectiveness of two DNA extraction kits, from QIAGEN and Zymo Research, to extract bacterial DNA genome from positive Leptospira spp. culture for downstream molecular detection. This study is an analytical observational study with a cross-sectional design conducted in June-September 2023, and part of the PESTO-RITA 2023 study. Fourteen identified positive Leptospira spp. culture, with Leptospira spp. movement under dark field microscopy, was used for DNA extraction using both extraction kits. QIAGEN kit yielded higher mean DNA concentration (0.900±0.161 vs 0.790±0.167 log10 µg/mL, p>0.05) and better DNA purity (1.854 vs 1.632, p<0.05) than the Zymo Research kit. PCR results, targeting the lipL32 gene, showed that two samples extracted with QIAGEN and one sample extracted with Zymo Research were positive for pathogenic Leptospira spp. Our preliminary results showed that QIAGEN kit yielded better DNA concentration and purity from positive Leptospira spp. culture.
- 26 August 2024
- Published by Poltekkes Kemenkes Yogyakarta in Jurnal Teknologi Laboratorium
- Vol. 13 (2) , 156-165
Open AccessOptimizing DNA extraction methods for enhanced detection of pathogenic Leptospira spp. in cultures using PCR
Leptospirosis is a worldwide zoonosis caused by Leptospira interrogans. Laboratory diagnosis of leptospirosis can be done through sample culture. However, microscopic observation of positive Leptospira spp. culture need to be supported by molecular detection to confirm the presence of pathogenic Leptospira spp. This study aimed to compare the effectiveness of two DNA extraction kits, from QIAGEN and Zymo Research, to extract bacterial DNA genome from positive Leptospira spp. culture for downstream molecular detection. This study is an analytical observational study with a cross-sectional design conducted in June-September 2023, and part of the PESTO-RITA 2023 study. Fourteen identified positive Leptospira spp. culture, with Leptospira spp. movement under dark field microscopy, was used for DNA extraction using both extraction kits. QIAGEN kit yielded higher mean DNA concentration (0.900±0.161 vs 0.790±0.167 log10 µg/mL, p>0.05) and better DNA purity (1.854 vs 1.632, p<0.05) than the Zymo Research kit. PCR results, targeting the lipL32 gene, showed that two samples extracted with QIAGEN and one sample extracted with Zymo Research were positive for pathogenic Leptospira spp. Our preliminary results showed that QIAGEN kit yielded better DNA concentration and purity from positive Leptospira spp. culture.
- Open Access
- 20 September 2022
- Published by Universitas Setia Budi in Biomedika
- Vol. 15 (1) , 25-30
Comparison Results of Hemoglobin Checkup in Pregnant Women using Cyanmethemoglobin Method and Azidemet Hb Methods
The hemoglobin checkup in pregnant women was done by several methods, some of those were Cyanmethemoglobin and Azidemet Hb methods. The incidence of anemia during pregnancy, childbirth and during the puerperium can be reduced by early detection of anemia by checking hemoglobin levels. The purpose of this study was to determine hemoglobin levels using the Cyanmethemoglobin method and the Azidemet Hb method. Data collection was carried out by observational method using cross sectional design. The research was conducted at the Ajibarang II Public Health Center, Banyumas Regency in October - November 2020. The sample used was 20 respondents. The results of the examination using the Cyanmethemoglobin method for venous blood were 10.12 ± 0.62 g / dL and the Azidemet Hb method for capillary blood was 11.98 ± 1,0009 g/dL. There is a significant difference between the results of hemoglobin examination using the Cyanmethemoglobin method of venous blood and the Azidemet Hb method of capilary blood.
- 20 September 2022
- Published by Universitas Setia Budi in Biomedika
- Vol. 15 (1) , 25-30
Open AccessComparison Results of Hemoglobin Checkup in Pregnant Women using Cyanmethemoglobin Method and Azidemet Hb Methods
The hemoglobin checkup in pregnant women was done by several methods, some of those were Cyanmethemoglobin and Azidemet Hb methods. The incidence of anemia during pregnancy, childbirth and during the puerperium can be reduced by early detection of anemia by checking hemoglobin levels. The purpose of this study was to determine hemoglobin levels using the Cyanmethemoglobin method and the Azidemet Hb method. Data collection was carried out by observational method using cross sectional design. The research was conducted at the Ajibarang II Public Health Center, Banyumas Regency in October - November 2020. The sample used was 20 respondents. The results of the examination using the Cyanmethemoglobin method for venous blood were 10.12 ± 0.62 g / dL and the Azidemet Hb method for capillary blood was 11.98 ± 1,0009 g/dL. There is a significant difference between the results of hemoglobin examination using the Cyanmethemoglobin method of venous blood and the Azidemet Hb method of capilary blood.
- Open Access
- 30 April 2022
- Published by Sekolah Tinggi Teknologi Warga Surakarta in Teknika
- Vol. 7 (3) , 152-156
RANCANG BANGUN KURSI PHLEBOTOMY BERBASIS IOT
Dewasa ini telah ditetapkan standar operasional prosedur untuk praktik venipuncture. Phlebotomyst yang melakukan tindakan tersebut harus memberi suatu alat pada area bawah siku pasien sebelum melakukan tindakan venipuncture. Fungsi alat ini salah satunya untuk memberikan kenyamanan pada pasien serta memudahkan akses flebotomis mencari pembuluh darah vena. Fakta di lapangan menunjukkan belum ada suatu alat fungsional yang khusus digunakan untuk phlebotomyst melakukan pengambilan darah vena secara efektif dan efisien. Alat yang biasa digunakan oleh phlebotomyst dapat berupa benda-benda apa saja yang difungsikan untuk meluruskan tangan pasien dan terkadang menggunakan benda-benda seadanya yang dapat menimbulkan ketidaknyamanan, kecemasan, menyebabkan terjadinya hematom dan media untuk menularkan penyakit serta kualitas dari sampel yang kurang baik. Tujuan dari penlitian ini adalah untuk membuat suatu alat yang dapat digunakan untuk memberikan kenyamanan pada pasien, serta mengurangi risiko terjadinya hematom (pecahnya pembuluh darah) saat dilakukan tindakan venepuncture. Pada penelitian ini, kursi phlebotomy berbasis IoT telah berhasil dibuat menggunakan Node MCU tsp 8266 serta linier actuator hidrolik. Bagian lengan pada kursi tersebut diberikan bantalan yang lembut serta dapat diatur ketingggiannya sesuai dengan kenyamanan tangan pasien. Pengaturan ketinggian dapat dilakukan secara otomatis menggunakan smartphone. Dengan adanya alat ini diharapkan pengambilan sampel darah pasien lebih efisen, efektif, serta memenuhi syarat dan standar, sehingga pasien merasa puas terhadap pelayanan laboratorium yang diberikan.
- 30 April 2022
- Published by Sekolah Tinggi Teknologi Warga Surakarta in Teknika
- Vol. 7 (3) , 152-156
Open AccessRANCANG BANGUN KURSI PHLEBOTOMY BERBASIS IOT
Dewasa ini telah ditetapkan standar operasional prosedur untuk praktik venipuncture. Phlebotomyst yang melakukan tindakan tersebut harus memberi suatu alat pada area bawah siku pasien sebelum melakukan tindakan venipuncture. Fungsi alat ini salah satunya untuk memberikan kenyamanan pada pasien serta memudahkan akses flebotomis mencari pembuluh darah vena. Fakta di lapangan menunjukkan belum ada suatu alat fungsional yang khusus digunakan untuk phlebotomyst melakukan pengambilan darah vena secara efektif dan efisien. Alat yang biasa digunakan oleh phlebotomyst dapat berupa benda-benda apa saja yang difungsikan untuk meluruskan tangan pasien dan terkadang menggunakan benda-benda seadanya yang dapat menimbulkan ketidaknyamanan, kecemasan, menyebabkan terjadinya hematom dan media untuk menularkan penyakit serta kualitas dari sampel yang kurang baik. Tujuan dari penlitian ini adalah untuk membuat suatu alat yang dapat digunakan untuk memberikan kenyamanan pada pasien, serta mengurangi risiko terjadinya hematom (pecahnya pembuluh darah) saat dilakukan tindakan venepuncture. Pada penelitian ini, kursi phlebotomy berbasis IoT telah berhasil dibuat menggunakan Node MCU tsp 8266 serta linier actuator hidrolik. Bagian lengan pada kursi tersebut diberikan bantalan yang lembut serta dapat diatur ketingggiannya sesuai dengan kenyamanan tangan pasien. Pengaturan ketinggian dapat dilakukan secara otomatis menggunakan smartphone. Dengan adanya alat ini diharapkan pengambilan sampel darah pasien lebih efisen, efektif, serta memenuhi syarat dan standar, sehingga pasien merasa puas terhadap pelayanan laboratorium yang diberikan.