Ismail Boudjemaa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ismail Boudjemaa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abdelghani Baltach
Mechanics of Materials, Energy and Environment Laboratory (L2M2E), University of Mustapha Stambouli, Mascara 29000, Algeria
1 shared publication - Abdelkader Benkhettou
Laboratory Mechanics Physics of Materials (LMPM), Department of Mechanical Engineering, University of Sidi Bel Abbes, Sidi Bel Abbes 22000, Algeria
1 shared publication - Abderahmene Sahli
Mechanical Engineering Department, Djillali Liabes of Sidi Bel Abbes University
1 shared publication - Belabbes Bachir Bouiadjra
LMPM, Department of Mechanical Engineering, University of Sidi Bel Abbes, Sidi Bel Abbes, Algeria
1 shared publication - Mohammed El Sallah Zagane
Department of Mechanical Engineering, University of Tiaret, Tiaret 14000, Algeria
1 shared publication - Mokhtar Messaad
Department of Technologies, University of Bordj Bou Arreridj, Bordj Bou Arreridj, Algeria
1 shared publication
Latest Publications
- 3 February 2026
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 71, 81-93
Biomechanical Analysis of Soft Tissue Thickness in Residual Limb: Impact on Stress Distribution and Interface Pressure in Prosthetic Fitting
The thickness of the residual limb’s soft tissue plays a crucial role in determining the mechanical behavior and stress distribution at the stump–prosthesis interface. Using finite element analysis (FEA), this study investigates the biomechanical effects of different soft tissue thicknesses (30 mm, 50 mm, and 70 mm) on stress distribution. A patient-specific finite element model of the residual limb was developed to simulate realistic anatomical and mechanical conditions. To replicate physiological loading, a static vertical load of 350 N was applied, and the interface between the residual limb and the prosthetic liner was modeled using appropriate contact mechanics. The results revealed that reducing the soft tissue thickness to 3 cm produced higher Von Mises stress concentrations (0.115 MPa) and contact pressure (0.0697 MPa), which may increase discomfort and the risk of tissue damage. Conversely, increasing the thickness to 70 mm reduced stress values (0.016 MPa) and contact pressure (0.0312 MPa) but led to excessive deformations (6.277 mm) that could compromise prosthetic stability. An optimal soft tissue thickness of 5 cm was identified, where Von Mises stress and contact pressure remained at moderate levels, offering a balance between stress distribution and mechanical stability. These findings provide valuable guidance for optimizing prosthetic socket design, as maintaining appropriate soft tissue thickness can enhance comfort, reduce pressure-related injuries, and improve the overall functionality of lower-limb prostheses.
- 3 February 2026
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 71, 81-93
Biomechanical Analysis of Soft Tissue Thickness in Residual Limb: Impact on Stress Distribution and Interface Pressure in Prosthetic Fitting
The thickness of the residual limb’s soft tissue plays a crucial role in determining the mechanical behavior and stress distribution at the stump–prosthesis interface. Using finite element analysis (FEA), this study investigates the biomechanical effects of different soft tissue thicknesses (30 mm, 50 mm, and 70 mm) on stress distribution. A patient-specific finite element model of the residual limb was developed to simulate realistic anatomical and mechanical conditions. To replicate physiological loading, a static vertical load of 350 N was applied, and the interface between the residual limb and the prosthetic liner was modeled using appropriate contact mechanics. The results revealed that reducing the soft tissue thickness to 3 cm produced higher Von Mises stress concentrations (0.115 MPa) and contact pressure (0.0697 MPa), which may increase discomfort and the risk of tissue damage. Conversely, increasing the thickness to 70 mm reduced stress values (0.016 MPa) and contact pressure (0.0312 MPa) but led to excessive deformations (6.277 mm) that could compromise prosthetic stability. An optimal soft tissue thickness of 5 cm was identified, where Von Mises stress and contact pressure remained at moderate levels, offering a balance between stress distribution and mechanical stability. These findings provide valuable guidance for optimizing prosthetic socket design, as maintaining appropriate soft tissue thickness can enhance comfort, reduce pressure-related injuries, and improve the overall functionality of lower-limb prostheses.
- 4 January 2025
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 47 (2) , 1-13
Biomechanical analysis of prosthetic liners in transfemoral amputees using finite element modeling
- 4 January 2025
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 47 (2) , 1-13
Biomechanical analysis of prosthetic liners in transfemoral amputees using finite element modeling