Xianzong Chao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xianzong Chao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Fuping Zeng
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
5 shared publications Xinghai Jiang
State Key Laboratory of Power Grid Environmental Protection School of Electrical Engineering and Automation Wuhan University Wuhan China
3 shared publicationsFuping Zeng
2 shared publications- Ju Tang
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
2 shared publications - Langlang Lv
Wuhan University
2 shared publications Tiancheng Zhao
2 shared publications
Latest Publications
- 22 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Diffusion characteristics of SF6 decomposition products in typical structural units of 500 kV GIL equipment
- 22 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Diffusion characteristics of SF6 decomposition products in typical structural units of 500 kV GIL equipment
- 3 February 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 454
Mode-mismatched photothermal lens-based trace furfural detection using a quantum cascade laser as excitation source
- 3 February 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 454
Mode-mismatched photothermal lens-based trace furfural detection using a quantum cascade laser as excitation source
- Open Access
- 5 June 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (5) , 1272-1281
Simulation of Hollow‐Core Photonic Crystal Fibre‐Based Photothermal Spectral C 2 H 2 Gas Sensor
Fault characteristic gas analysis is one of the important methods for monitoring the operating status of power equipment. This study presents the construction of a simulation model for a hollow‐core photonic crystal fibre (HC‐PCF)‐based photothermal spectroscopy gas detection system. The relationship between the phase change of the probe beam and the acetylene concentration, pump power, ambient temperature and the modulation frequency is examined. It is achieved by simulating the wavelength modulation of the pump beam and the phase change of the probe beam. The findings demonstrate that there is a linear positive correlation between the pump power and the amplitude of the phase change of the probe beam and the acetylene concentration. For example, acetylene concentration grew from 1 to 10,000 ppm, whereas phase change amplitude increased from 4.71 × 10 −4 to 3.70 rad. The pump power grew from 7 to 2000 mW, whereas phase change amplitude increased from 3.73 × 10 −4 to 1.01 × 10 −1 rad. The phase change of the probe beam is non‐linearly and negatively correlated with the ambient temperature. The ambient temperature decreases from 373.15 to 173.15 K, and phase change amplitude increases from 5.05 × 10 −3 to 2.15 × 10 −2 rad, an enhancement of 4.26 times. The modulation frequency is needed to balance the thermal conduction process in the HC‐PCF. In the 1–100 Hz range, the amplitude of the phase change is stable and almost independent of the modulation frequency. In the 100–40,000 Hz range, the amplitude of the phase change decreases rapidly with the increase of the modulation frequency. The results of the paper provide a reference for constructing the HC‐PCF‐based photothermal spectroscopy gas detection system.
- 5 June 2025
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 10 (5) , 1272-1281
Open AccessSimulation of Hollow‐Core Photonic Crystal Fibre‐Based Photothermal Spectral C 2 H 2 Gas Sensor
Fault characteristic gas analysis is one of the important methods for monitoring the operating status of power equipment. This study presents the construction of a simulation model for a hollow‐core photonic crystal fibre (HC‐PCF)‐based photothermal spectroscopy gas detection system. The relationship between the phase change of the probe beam and the acetylene concentration, pump power, ambient temperature and the modulation frequency is examined. It is achieved by simulating the wavelength modulation of the pump beam and the phase change of the probe beam. The findings demonstrate that there is a linear positive correlation between the pump power and the amplitude of the phase change of the probe beam and the acetylene concentration. For example, acetylene concentration grew from 1 to 10,000 ppm, whereas phase change amplitude increased from 4.71 × 10 −4 to 3.70 rad. The pump power grew from 7 to 2000 mW, whereas phase change amplitude increased from 3.73 × 10 −4 to 1.01 × 10 −1 rad. The phase change of the probe beam is non‐linearly and negatively correlated with the ambient temperature. The ambient temperature decreases from 373.15 to 173.15 K, and phase change amplitude increases from 5.05 × 10 −3 to 2.15 × 10 −2 rad, an enhancement of 4.26 times. The modulation frequency is needed to balance the thermal conduction process in the HC‐PCF. In the 1–100 Hz range, the amplitude of the phase change is stable and almost independent of the modulation frequency. In the 100–40,000 Hz range, the amplitude of the phase change decreases rapidly with the increase of the modulation frequency. The results of the paper provide a reference for constructing the HC‐PCF‐based photothermal spectroscopy gas detection system.
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 370-378
Fabry–Perot Interferometric C₂H₂ Gas Sensor Based on Spatially Coupled Hollow-Core Photonic Crystal Fiber
In this paper, a Fabry Perot interferometric cavity (F-P cavity) is formed by spatial coupling between single-mode fiber and hollow-core photonic crystal fiber. Based on this cavity, a photothermal spectrum detection system for trace acetylene (C2H2) is constructed. The actual effective length of the F-P cavity and the stability of the sensor's operating point are analyzed theoretically and experimentally. Combined with the wavelength modulation, the optimal modulation depth of the detection system corresponding to the sinusoidal amplitude, the optimal pump power and the optimal detection gas chamber pressure were determined to be 0.06 V, 2.732 mW and 2.75 atm, respectively. Under the optimal experimental conditions, detection experiments were carried out on several concentrations of C2H2. The results show that there is a good linear relationship between the net second harmonic signal amplitude and C2H2 concentration, the goodness of fit is 0.999. Based on Allan-Werle deviation analysis, the detection limits of 0.175 ppm for C2H2 at the integration time of 255 s were achieved, corresponding to the normalized noise equivalent absorption (NNEA) coefficient of 8.45 × 10-10 cm-1WHz-1/2. The results provide ideas and references for the establishment of trace gas HC-PCF detection.
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 370-378
Fabry–Perot Interferometric C₂H₂ Gas Sensor Based on Spatially Coupled Hollow-Core Photonic Crystal Fiber
In this paper, a Fabry Perot interferometric cavity (F-P cavity) is formed by spatial coupling between single-mode fiber and hollow-core photonic crystal fiber. Based on this cavity, a photothermal spectrum detection system for trace acetylene (C2H2) is constructed. The actual effective length of the F-P cavity and the stability of the sensor's operating point are analyzed theoretically and experimentally. Combined with the wavelength modulation, the optimal modulation depth of the detection system corresponding to the sinusoidal amplitude, the optimal pump power and the optimal detection gas chamber pressure were determined to be 0.06 V, 2.732 mW and 2.75 atm, respectively. Under the optimal experimental conditions, detection experiments were carried out on several concentrations of C2H2. The results show that there is a good linear relationship between the net second harmonic signal amplitude and C2H2 concentration, the goodness of fit is 0.999. Based on Allan-Werle deviation analysis, the detection limits of 0.175 ppm for C2H2 at the integration time of 255 s were achieved, corresponding to the normalized noise equivalent absorption (NNEA) coefficient of 8.45 × 10-10 cm-1WHz-1/2. The results provide ideas and references for the establishment of trace gas HC-PCF detection.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Performance of Hollow-Core Photonic Crystal Fiber-Based Trace C₂H₂ Detection System
In this article, we propose an optical sensor system utilizing the capabilities of hollow-core photonic crystal fiber (HC-PCF) to transmit excitation light and hold sample gas. The direct absorption response is examined for different modulation waveforms, pressures, frequencies, and concentrations. The experimental results show that the response signal has an obvious overshoot and spike. The overshoot and spike are more obvious under the sine modulation than the rectangular modulation. In the 1–500-Hz range, the system demonstrated optimum response characteristics at 5 Hz, corresponding to the maximum attenuation percentage. Furthermore, a positive correlation was observed between the attenuation percentage of light intensity ( ${A} _{\text {t}}$ ) and optical power ( ${A} _{\text {p}}$ ) with the pressure in the gas chamber within the range of 0.1–0.3 MPa. When the gas chamber is filled with 10000-ppm C2H2/N2 to 0.3 MPa, At and Ap are 47.98% and 22.73%, respectively. A good linear relationship exists between the attenuation value of photodetector (PD) output and target gas concentration with a correlation coefficient above 0.99 after 140 s. The theoretical minimum detection limit of C2H2 without the erbium-doped fiber amplifier (EDFA) is 49.28 ppm and the relative synthetic standard uncertainty is 3.35%. This article provides an idea for applying the HC-PCF-based gas sensing system.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Performance of Hollow-Core Photonic Crystal Fiber-Based Trace C₂H₂ Detection System
In this article, we propose an optical sensor system utilizing the capabilities of hollow-core photonic crystal fiber (HC-PCF) to transmit excitation light and hold sample gas. The direct absorption response is examined for different modulation waveforms, pressures, frequencies, and concentrations. The experimental results show that the response signal has an obvious overshoot and spike. The overshoot and spike are more obvious under the sine modulation than the rectangular modulation. In the 1–500-Hz range, the system demonstrated optimum response characteristics at 5 Hz, corresponding to the maximum attenuation percentage. Furthermore, a positive correlation was observed between the attenuation percentage of light intensity ( ${A} _{\text {t}}$ ) and optical power ( ${A} _{\text {p}}$ ) with the pressure in the gas chamber within the range of 0.1–0.3 MPa. When the gas chamber is filled with 10000-ppm C2H2/N2 to 0.3 MPa, At and Ap are 47.98% and 22.73%, respectively. A good linear relationship exists between the attenuation value of photodetector (PD) output and target gas concentration with a correlation coefficient above 0.99 after 140 s. The theoretical minimum detection limit of C2H2 without the erbium-doped fiber amplifier (EDFA) is 49.28 ppm and the relative synthetic standard uncertainty is 3.35%. This article provides an idea for applying the HC-PCF-based gas sensing system.
- 4 January 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 383
Signal correction using transmitted spot information: A low error photoacoustic spectroscopy-based gas detection system
- 4 January 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 383
Signal correction using transmitted spot information: A low error photoacoustic spectroscopy-based gas detection system
- Open Access
- 17 January 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (4) , 690-697
SF 6 decomposition behaviour under partial discharge of typical insulation defects in gas‐solid insulated valve‐side bushing of converter transformer
In this paper we investigated SF 6 decomposition behaviour of typical insulation defects in gas‐solid insulated converter transformer valve‐side bushing under partial discharge (PD). Additionally, we compared the results with that of gas insulated switchgear (GIS). The results indicated that SF 6 decomposition behaviour varies with the insulation defects type. For metal protrusion defects, the proportion ranking of CO 2 and SO 2 can be related to whether the needle tip is wrapped with epoxy resin‐impregnated paper (ERIP). The proportion of carbon‐containing products is much higher under contamination defect than under other defects. Moreover, the proportion of carbon‐containing components is higher under flashover condition than under PD condition and is accompanied by the appearance of H 2 S and CS 2 . However, the yield of SO 2 F 2 is always low. Compared to negative DC voltages, positive DC voltages have a higher proportion of carbon‐containing components, mainly in the form of more CO 2 and less SOF 2 . Compared to the PD decomposition behaviour of typical insulation defects in GIS, when PD involves ERIP, the proportion of carbon‐containing products, especially CO 2 , is significant higher, while the proportion of sulphur containing products, especially SO 2 F 2 , is lower.
- 17 January 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (4) , 690-697
Open AccessSF 6 decomposition behaviour under partial discharge of typical insulation defects in gas‐solid insulated valve‐side bushing of converter transformer
In this paper we investigated SF 6 decomposition behaviour of typical insulation defects in gas‐solid insulated converter transformer valve‐side bushing under partial discharge (PD). Additionally, we compared the results with that of gas insulated switchgear (GIS). The results indicated that SF 6 decomposition behaviour varies with the insulation defects type. For metal protrusion defects, the proportion ranking of CO 2 and SO 2 can be related to whether the needle tip is wrapped with epoxy resin‐impregnated paper (ERIP). The proportion of carbon‐containing products is much higher under contamination defect than under other defects. Moreover, the proportion of carbon‐containing components is higher under flashover condition than under PD condition and is accompanied by the appearance of H 2 S and CS 2 . However, the yield of SO 2 F 2 is always low. Compared to negative DC voltages, positive DC voltages have a higher proportion of carbon‐containing components, mainly in the form of more CO 2 and less SOF 2 . Compared to the PD decomposition behaviour of typical insulation defects in GIS, when PD involves ERIP, the proportion of carbon‐containing products, especially CO 2 , is significant higher, while the proportion of sulphur containing products, especially SO 2 F 2 , is lower.