AİAyşenur İşcan

Ayşenur İşcan

*This is an algorithmically generated author record based on publicly available information.

Ayşenur İşcan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of the parameter studies of different resins with DLP production technology, which is an additive manufacturing method, and determination of their suitability for production and use

    by Neşe Keklikcioğlu Çakmak, Osman Mavus, Ayşenur İşcan, Gökhan Alegöz, Fatih Özaydın, Funda Yaren Özaydın

    Additive manufacturing is used as a production method in many sectors nowadays. This method, which is used as an alternative to machining, is often preferred as an alternative to mass production lines in order to easily produce different geometries and different materials. Additive manufacturing has diversified with different production methods and different materials. For example, FDA - SLA - FDM - LASER etc. In our study, DLP (Digital Light Processing) production method, in which photopolymer resins are used as raw materials, was preferred. There are different reasons why we prefer this method; 1) DLP devices of our own production have adjustable parameter infrastructure for different resins. 2) The mechanical and characteristic properties of the materials preferred in the moving parts of the products that we plan to commercialize within the company should have similar mechanical and characteristic properties with the resins evaluated in this study. Within the scope of the planned study, 4 different resins were determined to meet the expected properties and parameter studies were carried out. As a result of the parameter studies, the desired results were obtained in 2 different resins and their suitability for use was confirmed. Parameters and visuals of the resins studied are given in table 1-2.With this work, we have developed the technological production infrastructure and incorporated a new material and production method into the company. In this way, we made a profit from mold - cutting tool, raw material etc. expenses.

  • Open Access

    Comparison of sterile inhalation water in oxygen humidifier bottles with tap water and investigation of antibacterial effects and endotoxin limits

    by Neşe Keklikcioğlu Çakmak, Osman Mavuş, Ayşenur İşcan, Gökhan Alegöz, Fatih Özaydın

    In hospitals, medical air feeders and oxygen are used to create dry gas. Patients who need oxygen may experience upper respiratory tract problems due to inhalation of dry oxygen. Therefore, the airway must be humidified while the patient is receiving oxygen. This humidification process is carried out using sterilized water. Oxygen flowmeter is an instrument used in hospitals to adjust the level of oxygen gases. Sterile inhalation waters connected to these flowmeters are used in inpatient wards, intensive care units, operating rooms and all areas where oxygen needs to be administered to the patient. In this study, parameters that will affect water quality such as endotoxin limits, antimicrobial effects and heavy metals contained in untreated, non-sterile tap water and disposable sterile inhalation waters were compared with international norms such as ISO 22519 Standard and European Pharmacopoeia. As a result of the analyzes, it has been proven that the waters contained in the sterile inhalation system produced by Estaş comply with international norms. In addition, it is foreseen that if sterile water cannot be used in hospitals, antibacterial, antiviral, antimicrobial negative effects will occur or if the same water is used more than once, cross-contamination will occur and different indications will occur. The use of sterile inhalation waters in accordance with the instructions for use reduces the risk of possible infection and ensures that the patient's saturation value reaches the desired level and provides ease of breathing. This solution aims to improve patient care conditions by reducing the risk of infection.