Oxana Aldoshina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oxana Aldoshina has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ali Dzhavanshirovich Mekhtiyev
Abylkas Saginov Karaganda Technical University
4 shared publications - Gavrilova Marianella
Abylkas Saginov Karaganda Technical University
3 shared publications - Yelena Neshina
Abylkas Saginov Karaganda Technical University
3 shared publications - Aliya D. Alkina
A. Burkitbayev Institute of Energy and Mechanical Engineering, K.I. Satbayev Kazakh National Research Technical University, Almaty 050013, Kazakhstan
2 shared publications - Belik Galina
Abylkas Saginov Karaganda Technical University,Communication systems technologies department,Karaganda,The Republic of Kazakhstan
2 shared publications - Nurbol Kaliaskarov
Abylkas Saginov Karaganda Technical University
2 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by MDPI AG in Preprints.org
Experimental and Theoretical Study of Energy Transfer Processes in Fiber-Optic Functional Systems with a GaAs-Based Photodiode Converter
A comprehensive experimental-theoretical study of a fiber-optic control and measurement system for simultaneous remote transmission of energy flows and information based on conversion of laser radiation into electrical energy using a gallium arsenide (GaAs) photoelectric converter is presented. The purpose of the study is to establish the effects of the wavelength of radiation, the geometric parameters of the optical fiber and the tem-perature regime of the converter on the energy characteristics of the system, as well as to develop a conceptual and theoretical generalized nonlinear physical and mathematical model of interconnected electrodynamic, kinetic and thermal processes in functional elements based on dielectric waveguides. The theoretical part of the study provides a conjugate description of the electromagnetic field, carrier transfer, relaxation polarization and heat transfer, based on Maxwell's equations, a generalized kinetic equation and a non-linear equation of thermal conductivity. The proposed closed system of equations (energy, material) of the model is generalized and requires, in the future, more specific (taking into account the specifics of physical processes in an optical fiber sample in an electromagnetic wave field) theoretical and numerical studies of the electrophysical and optical properties of materials of this class in a wide range of field parameters and temperatures (by comparing the results of theory and experiment). Six energy channel configurations were experimentally studied, formed by combinations of wavelengths of 650 and 850 nm and nominal fiber core diameters (9, 50 and 62.5 microns). The output electrical characteristics of the GaAs converter, the maximum load power and the tem-perature dependence of the normalized energy indicator are determined. The highest power output was 0.179 W at 850 nm and 0.146 W at 650 nm for a fiber with a core of 62.5 μm; the corresponding values of the energy indicator reached 0.559 and 0.456 (a de-crease in this indicator was established when the converter was heated). Experimentally confirmed the possibility of simultaneous transmission of energy and information on physically separate optical fibers. The results justify the need for a comprehensive consideration of optical losses, fiber geometry, photovoltaic converter characteristics and thermal conditions when designing remote optical power supply systems.
- 27 October 2026
- Published by MDPI AG in Preprints.org
Open AccessExperimental and Theoretical Study of Energy Transfer Processes in Fiber-Optic Functional Systems with a GaAs-Based Photodiode Converter
A comprehensive experimental-theoretical study of a fiber-optic control and measurement system for simultaneous remote transmission of energy flows and information based on conversion of laser radiation into electrical energy using a gallium arsenide (GaAs) photoelectric converter is presented. The purpose of the study is to establish the effects of the wavelength of radiation, the geometric parameters of the optical fiber and the tem-perature regime of the converter on the energy characteristics of the system, as well as to develop a conceptual and theoretical generalized nonlinear physical and mathematical model of interconnected electrodynamic, kinetic and thermal processes in functional elements based on dielectric waveguides. The theoretical part of the study provides a conjugate description of the electromagnetic field, carrier transfer, relaxation polarization and heat transfer, based on Maxwell's equations, a generalized kinetic equation and a non-linear equation of thermal conductivity. The proposed closed system of equations (energy, material) of the model is generalized and requires, in the future, more specific (taking into account the specifics of physical processes in an optical fiber sample in an electromagnetic wave field) theoretical and numerical studies of the electrophysical and optical properties of materials of this class in a wide range of field parameters and temperatures (by comparing the results of theory and experiment). Six energy channel configurations were experimentally studied, formed by combinations of wavelengths of 650 and 850 nm and nominal fiber core diameters (9, 50 and 62.5 microns). The output electrical characteristics of the GaAs converter, the maximum load power and the tem-perature dependence of the normalized energy indicator are determined. The highest power output was 0.179 W at 850 nm and 0.146 W at 650 nm for a fiber with a core of 62.5 μm; the corresponding values of the energy indicator reached 0.559 and 0.456 (a de-crease in this indicator was established when the converter was heated). Experimentally confirmed the possibility of simultaneous transmission of energy and information on physically separate optical fibers. The results justify the need for a comprehensive consideration of optical losses, fiber geometry, photovoltaic converter characteristics and thermal conditions when designing remote optical power supply systems.
- Open Access
- 23 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9464
Electrothermal Characteristics of the Electric–Vacuum Heat Pipe in a Low-Pressure Steam Electric Heater: Numerical Modeling and Experimental Study
This paper examines the electric–vacuum heat pipe (EVHP) as the main heat-transfer component of a low-pressure steam electric heater (LPSEH). The EVHP is interpreted as a wickless, closed, gravity-driven two-phase thermosiphon, in which active electrical power is supplied to the lower evaporation zone, while heat transfer to the outer surface is achieved through the evaporation of the working fluid, steam circulation, condensation and the gravitational return of the liquid phase. The aim of the study is to develop a theoretical and experimental description of the electrothermal regime of the EVHP and to establish the constraints governing the transition from a single smooth tube to a sectional instrument module. The proposed system distinguishes between the electrical input power, the heat generated in the evaporation zone, and the useful heat transferred from the external surface. An external convective–radiative balance was performed, along with numerical modeling in COMSOL Multiphysics and an experimental study on laboratory sections of the LPSEH. It was shown that a single smooth tube with a diameter of 32 mm and a length of 340 mm, at a surface temperature of 90 °C, provides a calculated heat-transfer rate of 16.3–52.8 W for the considered range of convection coefficients and emissivity (24.1–31.8 W under the baseline scenarios at h = 6 W/(m2·K)). In contrast, removal of 80 W of heat requires an equivalent heat-transfer area of 0.052–0.168 m2 (0.086–0.114 m2 under the baseline scenarios). Based on data from the main experimental program MP01–MP40, a regression model of the local temperature regime has been derived, relating the overheating in the upper zone of the section to the specific electrothermal load, the volume of the working fluid and the specific structural mass parameter. For the extended model, R2fit = 0.911, R2adj = 0.903, R2LOO = 0.887, MAELOO = 7.23 °C, and RMSELOO = 8.69 °C were obtained. Additional comparison showed the temperature sensitivity of the mode to the initial residual pressure and to the method of electrical heat supply. The obtained results justify the need for a developed surface, ribbing and sectional regulation of LPSEH. External heat transfer is estimated parametrically in the range of convection coefficient h and emissivity ε, which forms the design range of thermal power and the required surface area. The numerical model is verified by grid independence and energy balance, while the experimental program confirms the main electrothermal trends of the EVHP.
- 23 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9464
Open AccessElectrothermal Characteristics of the Electric–Vacuum Heat Pipe in a Low-Pressure Steam Electric Heater: Numerical Modeling and Experimental Study
This paper examines the electric–vacuum heat pipe (EVHP) as the main heat-transfer component of a low-pressure steam electric heater (LPSEH). The EVHP is interpreted as a wickless, closed, gravity-driven two-phase thermosiphon, in which active electrical power is supplied to the lower evaporation zone, while heat transfer to the outer surface is achieved through the evaporation of the working fluid, steam circulation, condensation and the gravitational return of the liquid phase. The aim of the study is to develop a theoretical and experimental description of the electrothermal regime of the EVHP and to establish the constraints governing the transition from a single smooth tube to a sectional instrument module. The proposed system distinguishes between the electrical input power, the heat generated in the evaporation zone, and the useful heat transferred from the external surface. An external convective–radiative balance was performed, along with numerical modeling in COMSOL Multiphysics and an experimental study on laboratory sections of the LPSEH. It was shown that a single smooth tube with a diameter of 32 mm and a length of 340 mm, at a surface temperature of 90 °C, provides a calculated heat-transfer rate of 16.3–52.8 W for the considered range of convection coefficients and emissivity (24.1–31.8 W under the baseline scenarios at h = 6 W/(m2·K)). In contrast, removal of 80 W of heat requires an equivalent heat-transfer area of 0.052–0.168 m2 (0.086–0.114 m2 under the baseline scenarios). Based on data from the main experimental program MP01–MP40, a regression model of the local temperature regime has been derived, relating the overheating in the upper zone of the section to the specific electrothermal load, the volume of the working fluid and the specific structural mass parameter. For the extended model, R2fit = 0.911, R2adj = 0.903, R2LOO = 0.887, MAELOO = 7.23 °C, and RMSELOO = 8.69 °C were obtained. Additional comparison showed the temperature sensitivity of the mode to the initial residual pressure and to the method of electrical heat supply. The obtained results justify the need for a developed surface, ribbing and sectional regulation of LPSEH. External heat transfer is estimated parametrically in the range of convection coefficient h and emissivity ε, which forms the design range of thermal power and the required surface area. The numerical model is verified by grid independence and energy balance, while the experimental program confirms the main electrothermal trends of the EVHP.
- 18 June 2026
- Published by Karaganda Technical University named after Abylkas Saginov in Trudy Universiteta
- Vol. 2 (103)
Comparative Analysis of the Characteristics of Wireless Wi-Fi Networks in GNU/ Linux and Windows 11 Environments
The present research investigates the performance characteristics of IEEE 802.11ax (Wi-Fi 6) wireless networks in GNU/Linux and Windows 11 environments. Particular attention is devoted to throughput, data transmission latency, CPU load, and RAM utilization [1, 2]. The study was carried out using a simulation-based methodology under identical hardware configurations and radio environment conditions for both operating systems. The obtained results indicate that architectural differences in network subsystems significantly affect connection quality metrics. In particular, GNU/Linux demonstrates higher throughput and lower latency, whereas Windows 11 exhibits increased CPU load and greater RAM consumption under comparable conditions. The research has practical relevance for selecting an operating system in the design and deployment of high-performance Wi-Fi networks
- 18 June 2026
- Published by Karaganda Technical University named after Abylkas Saginov in Trudy Universiteta
- Vol. 2 (103)
Comparative Analysis of the Characteristics of Wireless Wi-Fi Networks in GNU/ Linux and Windows 11 Environments
The present research investigates the performance characteristics of IEEE 802.11ax (Wi-Fi 6) wireless networks in GNU/Linux and Windows 11 environments. Particular attention is devoted to throughput, data transmission latency, CPU load, and RAM utilization [1, 2]. The study was carried out using a simulation-based methodology under identical hardware configurations and radio environment conditions for both operating systems. The obtained results indicate that architectural differences in network subsystems significantly affect connection quality metrics. In particular, GNU/Linux demonstrates higher throughput and lower latency, whereas Windows 11 exhibits increased CPU load and greater RAM consumption under comparable conditions. The research has practical relevance for selecting an operating system in the design and deployment of high-performance Wi-Fi networks
- 1 September 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (9) , 1470-1475
Development of magnetic resonance electrotechnique for scaliness reduction on heat exchange surfaces and in pipelines
- 1 September 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (9) , 1470-1475
Development of magnetic resonance electrotechnique for scaliness reduction on heat exchange surfaces and in pipelines
- Open Access
- 28 August 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (5 (136)) , 28-38
Design of a magnetic activator to prevent scale formation on the surface of tubular electric water heaters
The object of this study is the processes of scale formation in electric water heating systems when using water of increased hardness. The paper reports the design and testing of a magnetic activator to prevent scale formation on tubular electric heaters under hard water conditions without the use of chemical reagents. The device with neodymium magnets is installed on the supply pipeline of the water heater and solves the problem of scale formation without the use of chemical reagents. The experiment was conducted for 90 days on a laboratory bench simulating the operation of a domestic water heater. Magnetic treatment of water reduces the overall hardness by 15–20%, the content of Ca2⁺ and Mg2⁺ ions by 35–50% and forms predominantly an aragonite modification of calcium carbonate, which is less prone to strong adhesion to the heating surface. The thickness of the scale layer on the heating element is about 0.5 mm versus 2 mm in the control sample, which reduced additional energy costs from 13% to 3%. The effect is attributed to the action of magnetic field on the hydrate shells of hardness ions, which contributes to the formation of a less durable aragonite modification of calcium carbonate and disruption of the conditions for the crystallization of durable calcite on the heating surface. A unique feature of the device is a combination of internal and external magnetic activators based on neodymium magnets that generate a stable magnetic field with high induction, as well as the presence of a sump and design solutions that prevent contact of the magnets with water. This enables a long-term and targeted effect of the field on the water flow, which improves the efficiency of treatment. The magnetic activator is effective in domestic and industrial water heating systems with hard water; it increases the service life of the equipment, reduces energy consumption, and decreases the need for chemical reagents
- 28 August 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (5 (136)) , 28-38
Open AccessDesign of a magnetic activator to prevent scale formation on the surface of tubular electric water heaters
The object of this study is the processes of scale formation in electric water heating systems when using water of increased hardness. The paper reports the design and testing of a magnetic activator to prevent scale formation on tubular electric heaters under hard water conditions without the use of chemical reagents. The device with neodymium magnets is installed on the supply pipeline of the water heater and solves the problem of scale formation without the use of chemical reagents. The experiment was conducted for 90 days on a laboratory bench simulating the operation of a domestic water heater. Magnetic treatment of water reduces the overall hardness by 15–20%, the content of Ca2⁺ and Mg2⁺ ions by 35–50% and forms predominantly an aragonite modification of calcium carbonate, which is less prone to strong adhesion to the heating surface. The thickness of the scale layer on the heating element is about 0.5 mm versus 2 mm in the control sample, which reduced additional energy costs from 13% to 3%. The effect is attributed to the action of magnetic field on the hydrate shells of hardness ions, which contributes to the formation of a less durable aragonite modification of calcium carbonate and disruption of the conditions for the crystallization of durable calcite on the heating surface. A unique feature of the device is a combination of internal and external magnetic activators based on neodymium magnets that generate a stable magnetic field with high induction, as well as the presence of a sump and design solutions that prevent contact of the magnets with water. This enables a long-term and targeted effect of the field on the water flow, which improves the efficiency of treatment. The magnetic activator is effective in domestic and industrial water heating systems with hard water; it increases the service life of the equipment, reduces energy consumption, and decreases the need for chemical reagents
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 249-254
Development of a Structural and Functional Scheme of a Distributed Wi-Fi Monitoring System for Bridge Structures and Construction Buildings
The continuous monitoring of the technical condition of bridge structures and construction buildings is essential. Numerous methods, solutions, and developments exist for this purpose, each with its own set of advantages and disadvantages, reflecting the originality of the approaches proposed by various authors. Among the advantages are low power consumption, extensive coverage and range, and long service life. However, challenges such as complex programming, device compatibility issues, and intricate data network architectures also exist. This article discusses the functionalities of wireless remote monitoring systems for assessing the technical condition of bridge structures and construction buildings, focusing on the functional characteristics of their structural elements. The relevance of incorporating information and communication technologies is highlighted, and the selection of structural and functional elements is substantiated. A server for wireless data transmission has been chosen based on its advantages, as outlined in the article, to process and store the results. An algorithm detailing the operational steps and modes within each system block was developed based on the constructed structural and functional scheme. The objective of this study is to develop a structural and functional scheme for a remote monitoring system to assess the technical condition of construction facilities.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 249-254
Development of a Structural and Functional Scheme of a Distributed Wi-Fi Monitoring System for Bridge Structures and Construction Buildings
The continuous monitoring of the technical condition of bridge structures and construction buildings is essential. Numerous methods, solutions, and developments exist for this purpose, each with its own set of advantages and disadvantages, reflecting the originality of the approaches proposed by various authors. Among the advantages are low power consumption, extensive coverage and range, and long service life. However, challenges such as complex programming, device compatibility issues, and intricate data network architectures also exist. This article discusses the functionalities of wireless remote monitoring systems for assessing the technical condition of bridge structures and construction buildings, focusing on the functional characteristics of their structural elements. The relevance of incorporating information and communication technologies is highlighted, and the selection of structural and functional elements is substantiated. A server for wireless data transmission has been chosen based on its advantages, as outlined in the article, to process and store the results. An algorithm detailing the operational steps and modes within each system block was developed based on the constructed structural and functional scheme. The objective of this study is to develop a structural and functional scheme for a remote monitoring system to assess the technical condition of construction facilities.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 000255-000260
Temperature and Humidity Measurement Based on a Dual-Processor Wi-Fi System
The article describes the importance of measuring temperature and humidity in places such as: construction sites, buildings or bridges. In general, the reliability of all research results plays an important role in predicting the technical conditions of various facilities and in finding solutions to problems arising from the technical difficulties of remote control. In this regard, the issue of the validity of the choice of Wi-Fi modules operating in dual-processor mode, designed for receiving and transmitting measurement results, has been raised and resolved. In these modules, in order to obtain measurement results over a long time, the parameters of energy consumption and availability to programming of the boards are taken into account. Setting the energy consumption parameters allowed to increase the time for conducting research at remote sites, which in turn increases the durability and service life of the control system. Practical solutions for remote data transmission over a wireless communication network are proposed. The operability of the connected devices in a dual-processor wireless system has been verified.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 000255-000260
Temperature and Humidity Measurement Based on a Dual-Processor Wi-Fi System
The article describes the importance of measuring temperature and humidity in places such as: construction sites, buildings or bridges. In general, the reliability of all research results plays an important role in predicting the technical conditions of various facilities and in finding solutions to problems arising from the technical difficulties of remote control. In this regard, the issue of the validity of the choice of Wi-Fi modules operating in dual-processor mode, designed for receiving and transmitting measurement results, has been raised and resolved. In these modules, in order to obtain measurement results over a long time, the parameters of energy consumption and availability to programming of the boards are taken into account. Setting the energy consumption parameters allowed to increase the time for conducting research at remote sites, which in turn increases the durability and service life of the control system. Practical solutions for remote data transmission over a wireless communication network are proposed. The operability of the connected devices in a dual-processor wireless system has been verified.