Pawel Tomasz Pieta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pawel Tomasz Pieta has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jeppe Revall Frisvad
Technical University of Denmark, Kongens Lyngby, Denmark
4 shared publications - Anders Bjorholm Dahl
Technical University of Denmark
3 shared publications - Anders Nymark Christensen
Technical University of Denmark Kongens Lyngby Denmark
3 shared publications - Frans van Den Berg
Department of Food Science, Faculty of Science, University of Copenhagen, Rolighedsvej 26, DK-1958 Frederiksberg C, Denmark
2 shared publications - Harshkumar Patel
Department of Food Science, Faculty of Science, University of Copenhagen, Rolighedsvej 26, 1958 Frederiksberg C, Denmark
2 shared publications - Joana Ortega-Anaya
Department of Food Science and Technology, The Ohio State University, Columbus, OH 43210, USA
2 shared publications
Latest Publications
- Open Access
- 11 September 2026
- Published by Springer Nature
- p. 225-245
FaCT-GS: Fast and Scalable CT Reconstruction with Gaussian Splatting
Gaussian Splatting (GS) has emerged as a dominating technique for image rendering and has quickly been adapted for the X-ray Computed Tomography (CT) reconstruction task. However, despite its growing popularity, the benefits of GS are typically not substantial enough to motivate a transition from well-established reconstruction algorithms. This paper addresses the most significant remaining limitations of the GS-based approach by introducing FaCT-GS, a framework for fast and flexible CT reconstruction. Enabled by an in-depth optimization of the voxelization and rasterization pipelines, our new method is significantly faster than its predecessors and scales well with projection and output volume size. Furthermore, the improved voxelization enables rapid fitting of Gaussians to pre-existing volumes, which can serve as a prior for warm-starting the reconstruction, or simply as an alternative, compressed representation. FaCT-GS is over 4 $$\times $$ faster than the State of the Art GS CT reconstruction on standard $$512^2$$ projections, and over 13 $$\times $$ faster on 2k projections. Implementation and data available through: https://papieta.github.io/fact-gs/ .- 11 September 2026
- Published by Springer Nature
- p. 225-245
Open AccessFaCT-GS: Fast and Scalable CT Reconstruction with Gaussian Splatting
Gaussian Splatting (GS) has emerged as a dominating technique for image rendering and has quickly been adapted for the X-ray Computed Tomography (CT) reconstruction task. However, despite its growing popularity, the benefits of GS are typically not substantial enough to motivate a transition from well-established reconstruction algorithms. This paper addresses the most significant remaining limitations of the GS-based approach by introducing FaCT-GS, a framework for fast and flexible CT reconstruction. Enabled by an in-depth optimization of the voxelization and rasterization pipelines, our new method is significantly faster than its predecessors and scales well with projection and output volume size. Furthermore, the improved voxelization enables rapid fitting of Gaussians to pre-existing volumes, which can serve as a prior for warm-starting the reconstruction, or simply as an alternative, compressed representation. FaCT-GS is over 4 $$\times $$ faster than the State of the Art GS CT reconstruction on standard $$512^2$$ projections, and over 13 $$\times $$ faster on 2k projections. Implementation and data available through: https://papieta.github.io/fact-gs/ . - Open Access
- 21 October 2025
- Published by Elsevier in Journal of Food Engineering
- Vol. 407
Influence of sample size and spatial resolution on quantifying Mozzarella cheese microstructural properties: An X-ray tomography case study
- 21 October 2025
- Published by Elsevier in Journal of Food Engineering
- Vol. 407
Open AccessInfluence of sample size and spatial resolution on quantifying Mozzarella cheese microstructural properties: An X-ray tomography case study
- 24 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (22) , 6468-6478
Quantitative measurement of the anisotropy of a turbid medium using polarization imaging
Quantifying anisotropy in a turbid medium is critical for applications ranging from biomedical diagnostics to food quality assessment. Using a polarization camera and irradiation by a linearly polarized beam, we present a noninvasive method for estimating material anisotropy by analyzing depolarization ratios. To validate our approach, we perform a 3D microstructural analysis of mozzarella cheese samples to obtain ground-truth anisotropy levels using a metric based on structure tensor scale-space analysis of computed tomography (CT) scans. Our experiments with mozzarella samples of different anisotropy levels demonstrate a stronger correlation with CT-derived anisotropy and greater robustness as compared with oblique incidence reflectometry, which is limited by surface artifacts and sensitivity to sample orientation. Our method maintains high accuracy with simpler instrumentation and without sample rotation even when samples exhibit surface variations (non-flatness or texture). This establishes polarization imaging as a robust platform for noninvasive anisotropy characterization with potential applications in industrial quality control and biomedical diagnostics.
- 24 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (22) , 6468-6478
Quantitative measurement of the anisotropy of a turbid medium using polarization imaging
Quantifying anisotropy in a turbid medium is critical for applications ranging from biomedical diagnostics to food quality assessment. Using a polarization camera and irradiation by a linearly polarized beam, we present a noninvasive method for estimating material anisotropy by analyzing depolarization ratios. To validate our approach, we perform a 3D microstructural analysis of mozzarella cheese samples to obtain ground-truth anisotropy levels using a metric based on structure tensor scale-space analysis of computed tomography (CT) scans. Our experiments with mozzarella samples of different anisotropy levels demonstrate a stronger correlation with CT-derived anisotropy and greater robustness as compared with oblique incidence reflectometry, which is limited by surface artifacts and sensitivity to sample orientation. Our method maintains high accuracy with simpler instrumentation and without sample rotation even when samples exhibit surface variations (non-flatness or texture). This establishes polarization imaging as a robust platform for noninvasive anisotropy characterization with potential applications in industrial quality control and biomedical diagnostics.
- Open Access
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 9766-9779
Feature-Centered First Order Structure Tensor Scale-Space in 2D and 3D
The structure tensor method is often used for 2D and 3D analysis of imaged structures, but its results are in many cases very dependent on the user’s choice of method parameters. We simplify this parameter choice in first order structure tensor scale-space by directly connecting the width of the derivative filter to the size of image features. By introducing a ring-filter step, we substitute the Gaussian integration/smoothing with a method that more accurately shifts the derivative filter response from feature edges to their center. We further demonstrate how extracted structural measures can be used to correct known inaccuracies in the scale map, resulting in a reliable representation of the feature sizes both in 2D and 3D. Compared to the traditional first order structure tensor, or previous structure tensor scale-space approaches, our solution is much more accurate and can serve as an out-of-the-box method for extracting a wide range of structural parameters with minimal user input.
- 8 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 9766-9779
Open AccessFeature-Centered First Order Structure Tensor Scale-Space in 2D and 3D
The structure tensor method is often used for 2D and 3D analysis of imaged structures, but its results are in many cases very dependent on the user’s choice of method parameters. We simplify this parameter choice in first order structure tensor scale-space by directly connecting the width of the derivative filter to the size of image features. By introducing a ring-filter step, we substitute the Gaussian integration/smoothing with a method that more accurately shifts the derivative filter response from feature edges to their center. We further demonstrate how extracted structural measures can be used to correct known inaccuracies in the scale map, resulting in a reliable representation of the feature sizes both in 2D and 3D. Compared to the traditional first order structure tensor, or previous structure tensor scale-space approaches, our solution is much more accurate and can serve as an out-of-the-box method for extracting a wide range of structural parameters with minimal user input.