MMMikhail B. Manuilov

Mikhail B. Manuilov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mikhail B. Manuilov has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    IOON ONE MED Device Generates Singlet Hydrogen and Active Chlorine to Exhibit Antimicrobial Activity – an Experimental Study

    by M.B. Manuilov, A.V. Martynov, N.I. Sklyar, V.V. Minukhin, M.S. Biryukov, A.M. Manuilov

    The aim of the study was to investigate the in vitro antimicrobial activity against museum and circulating strains of microorganisms and fungi of an aqueous solution generated by the IOON ONE MED device containing atomic hydrogen and atomic (active) chlorine at a concentration of 1 mg/L as active substances and in vivo on a standardized model of purulent peritonitis in two variants – prophylactic (neutralization of bacteria) and therapeutic (effect on advanced infection). Methods. Microbiological methods were used to study the antimicrobial activity of new substances in vitro on museum and circulating strains of microorganisms, as well as fungi. The ability of the generated solution to exhibit antibiofilm effects on intubation tubes infected with resistant microorganisms was studied separately. In vivo study of the efficacy of the generated solution on a model of purulent peritonitis in mice was also conducted in two ways – by using the solution as a prophylactic agent (mixing live bacteria with the solution and then immediately testing the ability of bacteria to induce peritonitis) and by therapeutic effect by injecting the solution 3 hours after infection of mice and determining the number of surviving mice. Results. The results showed that the solution produced by the device worked as well as 0.05 % chlorhexidine and 3 % hydrogen peroxide. From the in vivo studies, it can be concluded that the drug under investigation does not cause acute toxicity: the injection of 1 mL of the generated solution intraperitoneally did not lead to the death of any mice. It was found that mixing 1:1 of the solution generated by the IOON ONE MED device with a suspension of P. aeruginosa #2261 and subsequent intraperitoneal injection into mice ensured 100 % survival of animals compared to 100 % mortality in the control group. When the mice were injected with the intraperitoneal solution three hours after infection with a lethal dose of the resistant hospital strain of P. aeruginosa #2261, a 40 % survival rate was observed compared to 100% mortality in the control group. The difference between the control and experimental groups was statistically significant. Conclusions. The solution generated by the IOON ONE MED device, containing atomic hydrogen and atomic chlorine, when used in combination, has strong antiseptic properties and has promising application for surface disinfection, despite its short residence time in solution.

  • Wideband Dual Polarized All-Metal Dipole Array for Base Stations of Mobile Communications

    by Konstantin Kobrin, Zimeng Li, Viktor Sledkov, Mikhail Manuilov

    In this paper the method of the operational frequency band extension of all-metal crossed dipole antennas is proposed. This class of antennas is applied in the base stations of mobile communications operating on the two slant polarizations tilted to horizon at ±45°. The novel modification of the all-metal crossed dipole antenna is studied in which the optimization of the dipole arms profile is based on the approximation by Bezier curves of third order. This approach ensures the fine tuning of the mutual coupling of crossed dipoles and the significant extension of operational frequency band. The crossed dipole antenna shows high characteristics within over-octave frequency band 1.35 … 2.85 GHz (2.1:1 bandwidth, relative bandwidth 71 °/ ° ), where S 11 < −15dB and isolation is 30dB. The beamwidth of radiation pattern in horizontal plane for the level −10dB remains rather stable within operational frequency band and it is equal to Δθ 0 .1 =134° … 123°. So, the beamwidth corresponds to the angular sector 120°, which is served by base station. The cross polarized component is no more than −20dB. The characteristics of 8-element linear antenna array of this kind of dipoles are investigated and it is shown that despite the mutual coupling of array elements the characteristics remain high within the entire over-octave frequency band 1.35 … 2.85 GHz.


  • A Novel Compact Design of Filters and Diplexers with Metal Housing Having Complicated Cross Section

    by Vyacheslav Rudakov, Victor Sledkov, Zimeng Li, Vladimir Taranenko, Mikhail Manuilov

    A novel design of the strip-line filters and diplexers of the base station antennas operating within frequency bands 824-880/900-960 MHz, 1710-1830/1885-2025 MHz and 1710-1880/1920-2170 MHz is proposed. The filters and diplexers have simple design since their all-metal strip-lines are fabricated as an entire piece of metal plate by punching technology. The suggested design of filters/diplexers doesn't contain tuning screws and the tuning procedure is not required. As a result, the proposed filters/diplexers have the easy-to-manufacture repeatable design which is suitable for the low-cost mass production. The filters are matched with standard 50 Ohm coaxial cable providing S11 $< -20$ dB and insertion loss is -0.35 dB within passband. The stop-band attenuation is better than - 20 dB. The reflection loss of diplexer is -19 dB, isolation between outputs is better than -26dB, insertion loss of both frequency bands is -0.55 dB. Thus, the proposed filters/diplexers are promising candidates for base station applications.

  • Open Access

    Fountains as potential sources of aerogenic risk for urban populations

    by A. Yu. Tretyakov, В. М. Московкин, Artur Martynov, M. B. Manuilov, Oleg V. Ermilov, Tatiana P. Osolodchenko

    Introduction. Fountains (office and outdoor), being small decorative structures used to improve the parameters of the human life environment, in the process of their work during the generation of a water jet, determine the creation of spray and aerosol fractions, thereby allowing the loss of a certain volume of liquid when air moves and wind carryover. The biological safety of the operation of such hydraulic structures depends on the composition of the microflora of the water in the main reservoir of the fountain, especially in the warm season. Materials and methods. For the period 2010-2020, the study of the composition of the microflora of water in the main reservoirs of the existing fountains and in the sedimented spray-aerosol mixture formed during the operation of these hydraulic structures was carried out. Results. At water temperatures above +18 °C and the absence of a disinfection system or its regular complete replacement, fountains were found to have a significant level of contamination with bacterial and fungal pathogens, including mycobacterium tuberculosis; the number of microorganisms of the E. coli group in office and open city fountains. The amount of Clostridial flora and streptococci in open fountains significantly exceeds the standard indicators (p <0.05). Limitations. When studying the trends in concentration of liquid particles in the air, the methodology of K.Y. Kondratiev et al. (1988) and V.M. Khvata et al. (1991) was used. The studies were carried out in accordance with the Interstate standard “Water. Methods of sanitary and bacteriological analysis for field conditions” GOST 24849-2014, 2016. Conclusion. The microflora of the operating fountain, in the absence of disinfection of water or its regular replacement, is characterized by a high titer of bacteria of the E. coli group, streptococci, staphylococci, mycobacterium tuberculosis, mold and yeast fungi. The one of the conditions for the excessive growth of these microorganisms in this hydraulic system is the water temperature above 18 °C. In the sedimented aerosol near the active fountain, a bacterial and fungal spectrum of pathogenic microorganisms similar to the water is found. Fountains (external and office) can be considered as sources of aerogenic household infection of the population of modern cities, which requires strict adherence to sanitary norms and rules that ensure the biological safety of these hydraulic structures.

  • Fast full-wave technique for CAD of polarizers based on double-ridge waveguide sections

    by Konstantin V. Kobrin, Mikhail B. Manuilov

    Full-wave technique for a computer-aided design (CAD) of a wide class of square waveguide 90-degree polarizers based on double-ridge sections is presented. The proposed hybrid full-wave technique for analysis of polarizers is based on the Galerkin method with taking into account the edge condition, mode-matching technique and generalized scattering matrix method. The weighted Gegenbauer polynomials are used as the basis functions taking into account the field asymptotic at the edges when solving the eigenvalue problem for a ridge waveguide. Compact Ku-band waveguide 90-degree polarizers are designed for operation within frequency bands 12–12.5/14–14.5 GHz and 12.1–12.5/17.7–18.1 GHz. VSWR within two operational bands of polarizers is less than 1.04, differential phase shift is about 90° ± 0.5° and 90° ± 1.5°, respectively. The length of polarizers is reduced at a factor about 2 in comparison with the known corrugated square waveguide polarizers.


  • Scattering of a Plane Electromagnetic Wave by a Multilayer Spherical Lens

    by P. O. Afanasyev, A. A. Akopov, A.M. Lehrer, M.B. Manuilov


  • Quasi‐analytical method for analysis of multisection waveguide structures with step discontinuities

    by V. P. Lyapin, M. B. Manuilov, G. P. Sinyavsky

    In this paper an effective quasi‐analytical field theory method for the analysis ofmultisection rectangular waveguide structures with E or H plane step discontinuities is presented. A version of Galerkin's method is used to solve the corresponding diffraction problems. The weghted Gegenbauer polynomials are used as basis functions, taking into account the field asymptotic at the discontinuity edges. Another important feature of the solution is the separation and analytical transform of the matrix operator static part of the obtained linear algebraic equations set. The method proposed here guarantees rapid convergence and high accuracy of the numerical results. It has been verified by numerical convergence investigation and comparison with the results of other works. The method can be applied for the effective design of a wide range of passive waveguide components: different band‐pass, stop‐band, and low‐pass filters, waveguide phase shifters, polarizers, etc. As examples of the concrete devise design, the characteristics of the inductive and capacitive iris filters, evanescent‐mode waveguide dielectric resonator filter, and E plane stub‐loaded, fixed‐phase shifter are given in the paper.