Lin Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lin Jin has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Lijun Zhang
Dalian Medical University, Dalian, China
2 shared publications - Yuhui Ao
School of Materials Science and Engineering Zhejiang Sci‐Tech University Hangzhou Zhejiang China
2 shared publications Yunfei Lan
DUT-BSU Joint Institute, Dalian University of Technology
2 shared publicationsBo Wang
School of Mechanics and Aerospace Engineering, Dalian University of Technology
1 shared publication- Bo Wang
School of Mechanics and Aerospace Engineering, Dalian University of Technology Dalian People's Republic of China
1 shared publication Chunlei Fan
Jilin Provincial Key Laboratory of Carbon Fiber Development and Application College of Chemistry and Life Science, Changchun University of Technology, Changchun 130012, China
1 shared publication
Latest Publications
- Open Access
- 28 October 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1850437
A critical review of the progress and application of finite element models in corneal biomechanics
Corneal morphology and biomechanics are the primary determinants of visual quality. Accurate biomechanical characterization is essential for optimizing the outcomes of refractive surgery and managing pathologies such as keratoconus. Finite element modeling is an established method used to simulate surgical procedures, predict mechanical responses, and investigate pathological mechanisms. This review evaluates the progression of corneal finite element models. Early work relied on idealized two-dimensional cross-sections or simplified three-dimensional shapes; today, researchers routinely build personalized, high-resolution three-dimensional reconstructions directly from clinical image data. Material descriptions have moved from basic isotropic linear elasticity to advanced hyperelastic, anisotropic, and viscoelastic formulations that more accurately simulate the physiological corneal behavior. This review also covers concrete applications in refractive surgery planning, corneal cross-linking optimization, and mechanistic studies of corneal pathology, as well as extensions to transplantation and orthokeratology. Taken together, these models provide reliable biomechanical evidence that supports individualized surgical design, refined cross-linking parameters, and improved graft assessment, steps that can increase the predictability and safety of modern ophthalmic procedures.
- 28 October 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1850437
Open AccessA critical review of the progress and application of finite element models in corneal biomechanics
Corneal morphology and biomechanics are the primary determinants of visual quality. Accurate biomechanical characterization is essential for optimizing the outcomes of refractive surgery and managing pathologies such as keratoconus. Finite element modeling is an established method used to simulate surgical procedures, predict mechanical responses, and investigate pathological mechanisms. This review evaluates the progression of corneal finite element models. Early work relied on idealized two-dimensional cross-sections or simplified three-dimensional shapes; today, researchers routinely build personalized, high-resolution three-dimensional reconstructions directly from clinical image data. Material descriptions have moved from basic isotropic linear elasticity to advanced hyperelastic, anisotropic, and viscoelastic formulations that more accurately simulate the physiological corneal behavior. This review also covers concrete applications in refractive surgery planning, corneal cross-linking optimization, and mechanistic studies of corneal pathology, as well as extensions to transplantation and orthokeratology. Taken together, these models provide reliable biomechanical evidence that supports individualized surgical design, refined cross-linking parameters, and improved graft assessment, steps that can increase the predictability and safety of modern ophthalmic procedures.
- 1 June 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (6) , 065012
Finite element analysis explores ablation depth and optical zone as key determinants of intraocular pressure reduction after refractive surgery
Background: with the increasing prevalence of refractive surgery, its impact on intraocular pressure (IOP) measurement has gained significant attention. This study aimed to elucidate the mechanism by which femtosecond laser-assisted in situ keratomileusis (FS-LASIK)-induced geometric alterations of the cornea affect IOP measurements obtained with the Goldmann applanation tonometer (GAT). Methods: IOP was measured with the GAT in patients undergoing FS-LASIK preoperatively and at 3 and 6 months postoperatively. A corneal finite element (FE) model, including aqueous humor for both pre- and post-operative states, was created to simulate the surgical volume required for correcting myopia of −2, −4, and −6 diopters (D). IOP values were calculated based on the principle of the GAT, and FE simulation results were compared with clinical IOP data measured using the GAT to validate the model. Results: Clinical data from GAT measurements demonstrated a consistent decrease in IOP following surgery. FE results indicated that the postoperative IOP, ranging from 8.26 mmHg to 13.04 mmHg, decreased by 23%–51% compared to the preoperative IOP of 17.04 mmHg. Deeper ablation depths and larger optical zone diameters were associated with lower postoperative IOP. Conclusion: The FE analysis demonstrated a decreasing trend in postoperative IOP with increasing ablation depth and optical zone diameter. These findings provide valuable insights for guiding postoperative IOP monitoring, optimizing surgical parameters, and understanding postoperative corneal biomechanical behavior.
- 1 June 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (6) , 065012
Finite element analysis explores ablation depth and optical zone as key determinants of intraocular pressure reduction after refractive surgery
Background: with the increasing prevalence of refractive surgery, its impact on intraocular pressure (IOP) measurement has gained significant attention. This study aimed to elucidate the mechanism by which femtosecond laser-assisted in situ keratomileusis (FS-LASIK)-induced geometric alterations of the cornea affect IOP measurements obtained with the Goldmann applanation tonometer (GAT). Methods: IOP was measured with the GAT in patients undergoing FS-LASIK preoperatively and at 3 and 6 months postoperatively. A corneal finite element (FE) model, including aqueous humor for both pre- and post-operative states, was created to simulate the surgical volume required for correcting myopia of −2, −4, and −6 diopters (D). IOP values were calculated based on the principle of the GAT, and FE simulation results were compared with clinical IOP data measured using the GAT to validate the model. Results: Clinical data from GAT measurements demonstrated a consistent decrease in IOP following surgery. FE results indicated that the postoperative IOP, ranging from 8.26 mmHg to 13.04 mmHg, decreased by 23%–51% compared to the preoperative IOP of 17.04 mmHg. Deeper ablation depths and larger optical zone diameters were associated with lower postoperative IOP. Conclusion: The FE analysis demonstrated a decreasing trend in postoperative IOP with increasing ablation depth and optical zone diameter. These findings provide valuable insights for guiding postoperative IOP monitoring, optimizing surgical parameters, and understanding postoperative corneal biomechanical behavior.
- 1 January 2025
- Published by American Vacuum Society in Biointerphases
- Vol. 20 (1)
Applications and latest research progress of liposomes in the treatment of ocular diseases
The special structure of eyes and the existence of various physiological barriers make ocular drug delivery one of the most difficult problems in the pharmaceutical field. Considering the problems of patient compliance, local administration remains the preferred method of drug administration in the anterior part of eyes. However, local administration suffers from poor bioavailability, need for frequent administration, and systemic toxicity. Administration in the posterior part of the eye is more difficult, and intravitreal injection is often used. But intravitreal injection faces the problems of poor patient compliance and likely side effects after multiple injections. The development of nanocarrier technology provides an effective way to solve these problems. Among them, liposomes, as the most widely used carrier in clinical application, have the characteristics of amphiphilic nanostructure, easy surface modification, extended release time, good biocompatibility, etc. The liposomes are expected to overcome obstacles and effectively deliver drugs to the target site to improve ocular drug bioavailability. This review summarized the various controllable properties of liposomes for ocular delivery as well as the application and research progress of liposomes in various ocular diseases. In addition, we summarized the physiological barriers and routes of administration contained in eyes, as well as the prospects of liposomes in the treatment of ocular diseases.
- 1 January 2025
- Published by American Vacuum Society in Biointerphases
- Vol. 20 (1)
Applications and latest research progress of liposomes in the treatment of ocular diseases
The special structure of eyes and the existence of various physiological barriers make ocular drug delivery one of the most difficult problems in the pharmaceutical field. Considering the problems of patient compliance, local administration remains the preferred method of drug administration in the anterior part of eyes. However, local administration suffers from poor bioavailability, need for frequent administration, and systemic toxicity. Administration in the posterior part of the eye is more difficult, and intravitreal injection is often used. But intravitreal injection faces the problems of poor patient compliance and likely side effects after multiple injections. The development of nanocarrier technology provides an effective way to solve these problems. Among them, liposomes, as the most widely used carrier in clinical application, have the characteristics of amphiphilic nanostructure, easy surface modification, extended release time, good biocompatibility, etc. The liposomes are expected to overcome obstacles and effectively deliver drugs to the target site to improve ocular drug bioavailability. This review summarized the various controllable properties of liposomes for ocular delivery as well as the application and research progress of liposomes in various ocular diseases. In addition, we summarized the physiological barriers and routes of administration contained in eyes, as well as the prospects of liposomes in the treatment of ocular diseases.
- 29 May 2023
- Published by Elsevier in Applied Surface Science
- Vol. 633, 157599
Cation π interactions trigger the oriented assembly of graphene oxide for designing high-performance carbon fiber composites
- 29 May 2023
- Published by Elsevier in Applied Surface Science
- Vol. 633, 157599
Cation π interactions trigger the oriented assembly of graphene oxide for designing high-performance carbon fiber composites
- 31 October 2019
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 58 (47) , 21441-21451
Three-dimensional Interconnected Nanosheet Architecture as a Transition Layer and Nanocontainer for Interfacial Enhancement of Carbon Fiber/Epoxy Composites
- 31 October 2019
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 58 (47) , 21441-21451
Three-dimensional Interconnected Nanosheet Architecture as a Transition Layer and Nanocontainer for Interfacial Enhancement of Carbon Fiber/Epoxy Composites
- 22 November 2014
- Published by Elsevier in Tetrahedron Letters
- Vol. 56 (1) , 225-228
Two novel isoquinoline alkaloids from the seedling of Corydalis decumbens
- 22 November 2014
- Published by Elsevier in Tetrahedron Letters
- Vol. 56 (1) , 225-228
Two novel isoquinoline alkaloids from the seedling of Corydalis decumbens
- 27 December 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 29 (2) , 766-780
Simulating the Formation of Surfactant-Templated Mesoporous Silica Materials: A Model with Both Surfactant Self-Assembly and Silica Polymerization
We have used Monte Carlo simulations to study the formation of the MCM-41 mesoporous silica material, with a new lattice model featuring explicit representations of both silicic acid condensation and surfactant self-assembly. Inspired by experimental syntheses, we have adopted the following two-step “synthesis” during our simulations: (i) high pH and low temperature allowing the initial onset of mesostructures with long-range order; (ii) lower pH and higher temperature promoting irreversible silica condensation. During step (i), the precursor solution was found to spontaneously separate into a surfactant–silicate-rich phase in equilibrium with a solvent-rich phase. Lamellar and hexagonal ordering emerged for the surfactant–silicate-rich mesosphases under different synthesis conditions, consistent with experimental observations. Under conditions where silica polymerization can be neglected, our simulations were found to transform reversibly between hexagonal and lamellar phases by changing temperature. During step (ii), silica polymerization was simulated at lower pH using reaction ensemble Monte Carlo to treat the pH dependence of silica deprotonation equilibria. Monte Carlo simulations produced silica–surfactant mesostructures with hexagonal arrays of pores and amorphous silica walls, exhibiting Qn distributions in reasonable agreement with 29Si NMR experiments on MCM-41. Compared with bulk amorphous silica, the wall domains of these simulated MCM-41 materials are characterized by even less order, larger fractions of 3- and 4-membered rings, and wider ring-size distributions.
- 27 December 2012
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 29 (2) , 766-780
Simulating the Formation of Surfactant-Templated Mesoporous Silica Materials: A Model with Both Surfactant Self-Assembly and Silica Polymerization
We have used Monte Carlo simulations to study the formation of the MCM-41 mesoporous silica material, with a new lattice model featuring explicit representations of both silicic acid condensation and surfactant self-assembly. Inspired by experimental syntheses, we have adopted the following two-step “synthesis” during our simulations: (i) high pH and low temperature allowing the initial onset of mesostructures with long-range order; (ii) lower pH and higher temperature promoting irreversible silica condensation. During step (i), the precursor solution was found to spontaneously separate into a surfactant–silicate-rich phase in equilibrium with a solvent-rich phase. Lamellar and hexagonal ordering emerged for the surfactant–silicate-rich mesosphases under different synthesis conditions, consistent with experimental observations. Under conditions where silica polymerization can be neglected, our simulations were found to transform reversibly between hexagonal and lamellar phases by changing temperature. During step (ii), silica polymerization was simulated at lower pH using reaction ensemble Monte Carlo to treat the pH dependence of silica deprotonation equilibria. Monte Carlo simulations produced silica–surfactant mesostructures with hexagonal arrays of pores and amorphous silica walls, exhibiting Qn distributions in reasonable agreement with 29Si NMR experiments on MCM-41. Compared with bulk amorphous silica, the wall domains of these simulated MCM-41 materials are characterized by even less order, larger fractions of 3- and 4-membered rings, and wider ring-size distributions.