Xuan Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xuan Lu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Chaoda Chen
School of Intelligent Manufacturing, Guangzhou Maritime University, Guangzhou 510725, China
2 shared publications - Baojian Zou
School of Electro-Mechanical Engineering, Guangdong University of Technology, Guangzhou, Guangdong, China
1 shared publication - Biaoqing Xu
School of Intelligent Manufacturing, Guangzhou Maritime University, Guangzhou 510725, China
1 shared publication - Caiming Zhong
School of Intelligent Manufacturing, Guangzhou Maritime University, Guangzhou 510725, China
1 shared publication - Chaoda Chen
School of Intelligent Manufacturing, Guangzhou Maritime University, Guangzhou, Guangdong, China
1 shared publication - Jindong Yu
School of Intelligent Manufacturing, Guangzhou Maritime University, Guangzhou 510725, China
1 shared publication
Latest Publications
- Open Access
Thermal Analysis and Parameter Optimization of the Ironing Process for FDM-Printed PLA and ABS Parts
The surface roughness of fused deposition modeling (FDM) parts severely limits their applications. Ironing, as an effective method to enhance surface quality, exhibits unclear interactions among its process parameters and lacks defined optimal process windows for different materials. To address this, this study employs a simulation to reveal the influence of ironing speed on the temperature field. Combining single-factor experiments with response surface methodology, predictive models for the surface roughness of PLA and ABS are established. Results indicate significant parameter interactions: PLA roughness is primarily governed by the interaction between ironing speed and ironing flow, while ABS roughness is co-influenced by the main effects of all three parameters (ironing speed, ironing flow, and ironing line spacing) as well as the interactions between speed and flow, and speed and line spacing. After optimization, the optimal surface roughness Ra values for PLA and ABS parts reached 0.852 μm and 1.014 μm, respectively. This study clarifies the dependence of ironing process effectiveness on material properties at the experimental optimization level, providing a theoretical basis for precise control of the FDM ironing process.
Open AccessThermal Analysis and Parameter Optimization of the Ironing Process for FDM-Printed PLA and ABS Parts
The surface roughness of fused deposition modeling (FDM) parts severely limits their applications. Ironing, as an effective method to enhance surface quality, exhibits unclear interactions among its process parameters and lacks defined optimal process windows for different materials. To address this, this study employs a simulation to reveal the influence of ironing speed on the temperature field. Combining single-factor experiments with response surface methodology, predictive models for the surface roughness of PLA and ABS are established. Results indicate significant parameter interactions: PLA roughness is primarily governed by the interaction between ironing speed and ironing flow, while ABS roughness is co-influenced by the main effects of all three parameters (ironing speed, ironing flow, and ironing line spacing) as well as the interactions between speed and flow, and speed and line spacing. After optimization, the optimal surface roughness Ra values for PLA and ABS parts reached 0.852 μm and 1.014 μm, respectively. This study clarifies the dependence of ironing process effectiveness on material properties at the experimental optimization level, providing a theoretical basis for precise control of the FDM ironing process.
- Open Access
- 13 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 187-191
Research on medical logistics robot localization based on ARTag code
Aiming to address the problems of insufficient positioning accuracy and the high cost of the localization system utilized by mobile handling robots in typical medical environments, an image recognition technology based on ARtag code is proposed. By examining the configuration of the camera module of the robot, the field of vision and the greatest visible distance of the robot are determined, and the principle of monocular target location is derived mathematically. Build an experimental platform, use visualization software to implement robot programming control, and conduct an experimental study on the effect of recognition distance and angle on the robot's recognition performance. The experimental results show that the recognition time of ARtag codes situated at different angles of 25cm and 35cm inside the robot's field of view is similar, with a fluctuation interval of less than 0.1s. The image recognition technology based on the ARtag code can effectively improve the stability of robot positioning performance under indoor conditions.
- 13 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 187-191
Open AccessResearch on medical logistics robot localization based on ARTag code
Aiming to address the problems of insufficient positioning accuracy and the high cost of the localization system utilized by mobile handling robots in typical medical environments, an image recognition technology based on ARtag code is proposed. By examining the configuration of the camera module of the robot, the field of vision and the greatest visible distance of the robot are determined, and the principle of monocular target location is derived mathematically. Build an experimental platform, use visualization software to implement robot programming control, and conduct an experimental study on the effect of recognition distance and angle on the robot's recognition performance. The experimental results show that the recognition time of ARtag codes situated at different angles of 25cm and 35cm inside the robot's field of view is similar, with a fluctuation interval of less than 0.1s. The image recognition technology based on the ARtag code can effectively improve the stability of robot positioning performance under indoor conditions.
- Open Access
An Experimental Study Based on Surface Microtexture of Medical Devices
Surface microstructures formed by jet electrolytic processing are widely used in aerospace and biomedical applications, and their unique process has an important role in medical devices. To improve the precision and usability of medical devices processed using this process, electrolytic characterization and micropit morphology experiments under different processing parameters were carried out to study the effect of EJM processing on processing efficiency and processing quality. The influencing factors of electrolytic machining rate were deduced by electrochemical theory, the electric field simulation was carried out using Comsol to analyze the electric field distribution and current density profile in the micropit, and the actual machining micropit was measured using a scanning microscope. The experiments show that increasing the peak voltage, reducing the machining gap, and extending the machining time can increase the depth of the micropit by 20%–40% and reduce the height of the silo by 45%–65%, which can effectively improve the surface structure of the medical device.
Open AccessAn Experimental Study Based on Surface Microtexture of Medical Devices
Surface microstructures formed by jet electrolytic processing are widely used in aerospace and biomedical applications, and their unique process has an important role in medical devices. To improve the precision and usability of medical devices processed using this process, electrolytic characterization and micropit morphology experiments under different processing parameters were carried out to study the effect of EJM processing on processing efficiency and processing quality. The influencing factors of electrolytic machining rate were deduced by electrochemical theory, the electric field simulation was carried out using Comsol to analyze the electric field distribution and current density profile in the micropit, and the actual machining micropit was measured using a scanning microscope. The experiments show that increasing the peak voltage, reducing the machining gap, and extending the machining time can increase the depth of the micropit by 20%–40% and reduce the height of the silo by 45%–65%, which can effectively improve the surface structure of the medical device.