Jingbin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jingbin Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Daniele Passaretti
Research Campus STIMULATE, Otto von Guericke University Magdeburg, Magdeburg, Germany
2 shared publications Hui Lao
Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, China
2 shared publications- Nicola D'AScenzo
Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, China
2 shared publications - Qingguo Xie
Huazhong University of Science and Technology
2 shared publications Yuexuan Hua
RAYQUANT Technology Company Ltd., Ezhou, China
2 shared publicationsBaolong Ma
1 shared publication
Latest Publications
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (6) , 747-755
Experimental Study of a Large Area High PDE SiPM in 0.11- μ m CMOS Process for PET Applications
Silicon photomultipliers (SiPMs) fabricated in a standard complementary metal-oxide-semiconductor (CMOS) process enable the development of cost-effective, reliable, and power-efficient photosensors for positron emission tomography (PET) applications. However, PET manufacturers prefer SiPMs in customized technologies for their high photon detection efficiency (PDE) and low noise, which are crucial parameters for energy and time resolution in PET scanners. Recently, RAYQUANT Technology Ltd. has developed a high PDE SiPM fabricated in 0.11 CMOS process, with large area of 9 mm. This paper investigates for the first time the ability of this SiPM to collect scintillation light from LYSO crystals for PET applications, evaluating energy resolution, and coincidence time resolution (CTR). The LYSO/SiPM detector achieves the best energy resolution (FWHM) of (28.0±1.0)% at 60 keV, (10.6±0.4)% at 511 keV, and (8.5±0.4)% at 662 keV. The best CTR (FWHM) is (172±2) ps, (147±2) ps, and (115±1) ps, when the SiPM is coupled to crystals of 20 mm, 10 mm, and 5 mm length, respectively. These results confirm that the studied CMOS-based SiPM is not only suitable for PET applications but is even competitive with SiPMs fabricated in customized technologies.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (6) , 747-755
Experimental Study of a Large Area High PDE SiPM in 0.11- μ m CMOS Process for PET Applications
Silicon photomultipliers (SiPMs) fabricated in a standard complementary metal-oxide-semiconductor (CMOS) process enable the development of cost-effective, reliable, and power-efficient photosensors for positron emission tomography (PET) applications. However, PET manufacturers prefer SiPMs in customized technologies for their high photon detection efficiency (PDE) and low noise, which are crucial parameters for energy and time resolution in PET scanners. Recently, RAYQUANT Technology Ltd. has developed a high PDE SiPM fabricated in 0.11 CMOS process, with large area of 9 mm. This paper investigates for the first time the ability of this SiPM to collect scintillation light from LYSO crystals for PET applications, evaluating energy resolution, and coincidence time resolution (CTR). The LYSO/SiPM detector achieves the best energy resolution (FWHM) of (28.0±1.0)% at 60 keV, (10.6±0.4)% at 511 keV, and (8.5±0.4)% at 662 keV. The best CTR (FWHM) is (172±2) ps, (147±2) ps, and (115±1) ps, when the SiPM is coupled to crystals of 20 mm, 10 mm, and 5 mm length, respectively. These results confirm that the studied CMOS-based SiPM is not only suitable for PET applications but is even competitive with SiPMs fabricated in customized technologies.
- 16 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (2) , 769-777
A Low-Noise High-Photon Detection Efficiency Silicon Photomultiplier in 0.11-μm CMOS
Silicon photomultipliers (SiPMs) fabricated using standard CMOS processes offer the advantages of compatibility with on-chip digital circuits, making them promising candidates among low-photon flux sensors. However, the high noise and low-photon detection efficiency (PDE) of CMOS SiPMs have limited their widespread adoption. Here, we present a novel SiPM obtained within a standard 0.11-$\mu $ m CMOS process. We report how guard ring (GR) width and distance from shallow trench isolation (STI) may affect the noise performance, and we optimize for them. The final device demonstrates performance that is competitive with both custom-based commercial technologies and other CMOS-based SiPMs, featuring an unprecedented peak PDE of 62% at 420 nm, a dark count rate (DCR) of$\mathbf {\text {(}{174}\pm {7}\text {)}}$ kcps/mm$\mathbf {^{{2}}}$ , a gain of$\mathbf {\text {(}{2}.{0}\pm {0}.{2}\text {)}\times {10}^{{6}}}$ and a single-photon time resolution (SPTR) of$\mathbf {\text {(}{74}\pm {3} \text {)}}$ ps [full width at half maximum (FWHM)] at an excess bias voltage of 3 V.- 16 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (2) , 769-777
A Low-Noise High-Photon Detection Efficiency Silicon Photomultiplier in 0.11-μm CMOS
Silicon photomultipliers (SiPMs) fabricated using standard CMOS processes offer the advantages of compatibility with on-chip digital circuits, making them promising candidates among low-photon flux sensors. However, the high noise and low-photon detection efficiency (PDE) of CMOS SiPMs have limited their widespread adoption. Here, we present a novel SiPM obtained within a standard 0.11-$\mu $ m CMOS process. We report how guard ring (GR) width and distance from shallow trench isolation (STI) may affect the noise performance, and we optimize for them. The final device demonstrates performance that is competitive with both custom-based commercial technologies and other CMOS-based SiPMs, featuring an unprecedented peak PDE of 62% at 420 nm, a dark count rate (DCR) of$\mathbf {\text {(}{174}\pm {7}\text {)}}$ kcps/mm$\mathbf {^{{2}}}$ , a gain of$\mathbf {\text {(}{2}.{0}\pm {0}.{2}\text {)}\times {10}^{{6}}}$ and a single-photon time resolution (SPTR) of$\mathbf {\text {(}{74}\pm {3} \text {)}}$ ps [full width at half maximum (FWHM)] at an excess bias voltage of 3 V.