Viktoryia Chaprasava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Viktoryia Chaprasava has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dzmitry S. Kharytonau
Electrochemistry and Corrosion Laboratory, Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences, Kraków, Poland
2 shared publications - Ewa Dryzek
Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Kraków, Poland
1 shared publication - Ewelina Jarek
Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences, Niezapominajek 8, 30-239 Kraków, Poland
1 shared publication Grzegorz Mordarski
Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences
1 shared publication- Grzegorz Mordarski
Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences, Niezapominajek 8, 30-239 Kraków, Poland
1 shared publication - Irina Kurilo
Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences
1 shared publication
Latest Publications
- Open Access
- 19 September 2026
- Published by Elsevier in SSRN Electronic Journal
Dual effect of surface mechanical attrition treatment and phosphate conversion coatings on long-term corrosion resistance of pure magnesium in 0.9% NaCl solution
This study investigates how surface modification of commercially pure magnesium influences the formation, microstructure, and long-term protective performance of phosphate conversion coatings (PCCs). An iron-free Surface Mechanical Attrition Treatment (SMAT) setup using zirconium dioxide balls of two diameters was employed to generate substantially different surface roughness while maintaining comparable subsurface modification, providing an experimental basis for isolating the effects of surface topography on PCC formation. PCCs were deposited on SMAT-treated and as-polished substrates and characterized using complementary microscopic, spectroscopic, and electrochemical techniques. The comparable subsurface modification but distinct surface topographies indicate that differences in PCC formation cannot be attributed solely to subsurface deformation. Instead, surface topography appears to influence coating nucleation and subsequent growth, with consequences for corrosion protection. SMAT pretreatment resulted in thinner, more uniform coatings composed of finer phosphate crystals. In contrast, coatings formed on polished substrates were more than twice as thick and exhibited inferior long-term corrosion performance, whereas those on SMAT-treated substrates remained highly stable throughout 28 days of immersion in 0.9 wt.% NaCl solution. These findings demonstrate that controlling magnesium surface state prior to phosphating enables tailoring of conversion coating structure and long-term protective performance.
- 19 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDual effect of surface mechanical attrition treatment and phosphate conversion coatings on long-term corrosion resistance of pure magnesium in 0.9% NaCl solution
This study investigates how surface modification of commercially pure magnesium influences the formation, microstructure, and long-term protective performance of phosphate conversion coatings (PCCs). An iron-free Surface Mechanical Attrition Treatment (SMAT) setup using zirconium dioxide balls of two diameters was employed to generate substantially different surface roughness while maintaining comparable subsurface modification, providing an experimental basis for isolating the effects of surface topography on PCC formation. PCCs were deposited on SMAT-treated and as-polished substrates and characterized using complementary microscopic, spectroscopic, and electrochemical techniques. The comparable subsurface modification but distinct surface topographies indicate that differences in PCC formation cannot be attributed solely to subsurface deformation. Instead, surface topography appears to influence coating nucleation and subsequent growth, with consequences for corrosion protection. SMAT pretreatment resulted in thinner, more uniform coatings composed of finer phosphate crystals. In contrast, coatings formed on polished substrates were more than twice as thick and exhibited inferior long-term corrosion performance, whereas those on SMAT-treated substrates remained highly stable throughout 28 days of immersion in 0.9 wt.% NaCl solution. These findings demonstrate that controlling magnesium surface state prior to phosphating enables tailoring of conversion coating structure and long-term protective performance.
- Open Access
- 16 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Effect of Permanganate Ions on Corrosion Inhibition of Mg-Al-Mn Alloys Containing Different Amounts of Li
Lithium-containing magnesium alloys are promising materials for high-demanding industrial applications. In the present contribution, three different AZ31 magnesium alloys AZ31-xLi (x = 4, 8, and 12 wt.%) were cast and their corrosion processes were examined in 0.05 M NaCl solution utilizing potassium permanganate as a potential corrosion inhibitor. The microstructure of the alloys was analyzed by scanning electron microscopy. Scanning Kelvin probe force microscopy demonstrated high susceptibility of the alloys to localized corrosion attack. Electrochemical techniques showed high effectiveness of the permanganate inhibitor (up to 97%) at concentrations starting from 10–50 mM. Post-corrosion surface analyses allowed establishment of the corrosion inhibition mechanism based on the reduction of permanganate ions on the surface of AZ31-xLi alloys to form an insoluble protective layer of Mn(IV) oxide.
- 16 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEffect of Permanganate Ions on Corrosion Inhibition of Mg-Al-Mn Alloys Containing Different Amounts of Li
Lithium-containing magnesium alloys are promising materials for high-demanding industrial applications. In the present contribution, three different AZ31 magnesium alloys AZ31-xLi (x = 4, 8, and 12 wt.%) were cast and their corrosion processes were examined in 0.05 M NaCl solution utilizing potassium permanganate as a potential corrosion inhibitor. The microstructure of the alloys was analyzed by scanning electron microscopy. Scanning Kelvin probe force microscopy demonstrated high susceptibility of the alloys to localized corrosion attack. Electrochemical techniques showed high effectiveness of the permanganate inhibitor (up to 97%) at concentrations starting from 10–50 mM. Post-corrosion surface analyses allowed establishment of the corrosion inhibition mechanism based on the reduction of permanganate ions on the surface of AZ31-xLi alloys to form an insoluble protective layer of Mn(IV) oxide.