Fangwei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fangwei Wu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Changjie Han
College of Mechanical and Electrical Engineering, Xinjiang Agricultural University, Urumqi 830052, China
3 shared publications - Dongdong Song
College of Mechanical and Electrical Engineering, Xinjiang Agricultural University, Urumqi 830052, China
3 shared publications - Yi Wu
College of Mechanical and Electrical Engineering, Xinjiang Agricultural University, Urumqi 830052, China
2 shared publications - Zhai Shi
College of Mechanical and Electrical Engineering, Xinjiang Agricultural University, Urumqi 830052, China
2 shared publications - Zhai Shi
College of Mechanical and Electrical Engineering, Xinjiang Agricultural University, Urumqi 830052, China
1 shared publication
Latest Publications
- Open Access
- 18 October 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (20) , 2165
Cotton Picker Fire Risk Analysis and Dynamic Threshold Setting Using Multi-Point Sensing and Seed Cotton Moisture
Fire hazards during cotton picker operations pose a significant safety concern, primarily caused by cotton blockages and friction-induced heat generation between the picking spindle and seed cotton under high-load conditions. Existing fire monitoring systems typically employ a uniform temperature threshold across multiple sensors. However, this approach overlooks the distinct characteristics of different cotton picker mechanisms and the influence of seed cotton moisture content, resulting in frequent false alarms and missed detections. To address these issues, this study pioneers and tests a dynamic, tiered temperature threshold warning strategy. This approach accounts for key cotton picker components and varying seed cotton moisture content (MC), specifically MC 9–12% and MC 12–15%. Additionally, based on the operational characteristics of the cotton conveying tube, this study proposes monitoring the wall surface temperature of the conveying tube and investigates the threshold for this temperature. Results indicate that during seed cotton open burning, the average temperature is 324 °C for MC < 9%, 261.9 °C for MC 9–12%, and 178.4 °C for MC 12–15%. After transitioning to smoldering, the temperatures were 226.6 °C, 191.5 °C, and 163.5 °C, respectively, with 163.5 °C being the lowest threshold for seed cotton open burning in the cotton bin. For smoldering seed cotton, the temperature thresholds were 240 °C for MC < 9% and MC 9–12%, and 280 °C for MC 12–15%. The temperature threshold for the cotton conveyor pipe wall surface was 49 °C. The friction-induced heat generation temperature threshold at the picking head, determined through combined testing and simulation, is set at 289 °C for MC < 9%, 306 °C for MC 9–12%, and 319 °C for MC 12–15%. The aforementioned tiered early warning strategy, developed through multi-source experiments and simulations, can be directly configured into controllers. It enables dynamic threshold alarms based on harvester location, seed cotton moisture content, and temperature zones, providing quantitative support for cotton harvester fire monitoring and risk management.
- 18 October 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (20) , 2165
Open AccessCotton Picker Fire Risk Analysis and Dynamic Threshold Setting Using Multi-Point Sensing and Seed Cotton Moisture
Fire hazards during cotton picker operations pose a significant safety concern, primarily caused by cotton blockages and friction-induced heat generation between the picking spindle and seed cotton under high-load conditions. Existing fire monitoring systems typically employ a uniform temperature threshold across multiple sensors. However, this approach overlooks the distinct characteristics of different cotton picker mechanisms and the influence of seed cotton moisture content, resulting in frequent false alarms and missed detections. To address these issues, this study pioneers and tests a dynamic, tiered temperature threshold warning strategy. This approach accounts for key cotton picker components and varying seed cotton moisture content (MC), specifically MC 9–12% and MC 12–15%. Additionally, based on the operational characteristics of the cotton conveying tube, this study proposes monitoring the wall surface temperature of the conveying tube and investigates the threshold for this temperature. Results indicate that during seed cotton open burning, the average temperature is 324 °C for MC < 9%, 261.9 °C for MC 9–12%, and 178.4 °C for MC 12–15%. After transitioning to smoldering, the temperatures were 226.6 °C, 191.5 °C, and 163.5 °C, respectively, with 163.5 °C being the lowest threshold for seed cotton open burning in the cotton bin. For smoldering seed cotton, the temperature thresholds were 240 °C for MC < 9% and MC 9–12%, and 280 °C for MC 12–15%. The temperature threshold for the cotton conveyor pipe wall surface was 49 °C. The friction-induced heat generation temperature threshold at the picking head, determined through combined testing and simulation, is set at 289 °C for MC < 9%, 306 °C for MC 9–12%, and 319 °C for MC 12–15%. The aforementioned tiered early warning strategy, developed through multi-source experiments and simulations, can be directly configured into controllers. It enables dynamic threshold alarms based on harvester location, seed cotton moisture content, and temperature zones, providing quantitative support for cotton harvester fire monitoring and risk management.
- Open Access
- 25 July 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (15) , 1608
Detection Model for Cotton Picker Fire Recognition Based on Lightweight Improved YOLOv11
In response to the limited research on fire detection in cotton pickers and the issue of low detection accuracy in visual inspection, this paper proposes a computer vision-based detection method. The method is optimized according to the structural characteristics of cotton pickers, and a lightweight improved YOLOv11 algorithm is designed for cotton fire detection in cotton pickers. The backbone of the model is replaced with the MobileNetV2 network to achieve effective model lightweighting. In addition, the convolutional layers in the original C3k2 block are optimized using partial convolutions to reduce computational redundancy and improve inference efficiency. Furthermore, a visual attention mechanism named CBAM-ECA (Convolutional Block Attention Module-Efficient Channel Attention) is designed to suit the complex working conditions of cotton pickers. This mechanism aims to enhance the model’s feature extraction capability under challenging environmental conditions, thereby improving overall detection accuracy. To further improve localization performance and accelerate convergence, the loss function is also modified. These improvements enable the model to achieve higher precision in fire detection while ensuring fast and accurate localization. Experimental results demonstrate that the improved model reduces the number of parameters by 38%, increases the frame processing speed (FPS) by 13.2%, and decreases the computational complexity (GFLOPs) by 42.8%, compared to the original model. The detection accuracy for flaming combustion, smoldering combustion, and overall detection is improved by 1.4%, 3%, and 1.9%, respectively, with an increase of 2.4% in mAP (mean average precision). Compared to other models—YOLOv3-tiny, YOLOv5, YOLOv8, and YOLOv10—the proposed method achieves higher detection accuracy by 5.9%, 7%, 5.9%, and 5.3%, respectively, and shows improvements in mAP by 5.4%, 5%, 4.8%, and 6.3%. The improved detection algorithm maintains high accuracy while achieving faster inference speed and fewer model parameters. These improvements lay a solid foundation for fire prevention and suppression in cotton collection boxes on cotton pickers.
- 25 July 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (15) , 1608
Open AccessDetection Model for Cotton Picker Fire Recognition Based on Lightweight Improved YOLOv11
In response to the limited research on fire detection in cotton pickers and the issue of low detection accuracy in visual inspection, this paper proposes a computer vision-based detection method. The method is optimized according to the structural characteristics of cotton pickers, and a lightweight improved YOLOv11 algorithm is designed for cotton fire detection in cotton pickers. The backbone of the model is replaced with the MobileNetV2 network to achieve effective model lightweighting. In addition, the convolutional layers in the original C3k2 block are optimized using partial convolutions to reduce computational redundancy and improve inference efficiency. Furthermore, a visual attention mechanism named CBAM-ECA (Convolutional Block Attention Module-Efficient Channel Attention) is designed to suit the complex working conditions of cotton pickers. This mechanism aims to enhance the model’s feature extraction capability under challenging environmental conditions, thereby improving overall detection accuracy. To further improve localization performance and accelerate convergence, the loss function is also modified. These improvements enable the model to achieve higher precision in fire detection while ensuring fast and accurate localization. Experimental results demonstrate that the improved model reduces the number of parameters by 38%, increases the frame processing speed (FPS) by 13.2%, and decreases the computational complexity (GFLOPs) by 42.8%, compared to the original model. The detection accuracy for flaming combustion, smoldering combustion, and overall detection is improved by 1.4%, 3%, and 1.9%, respectively, with an increase of 2.4% in mAP (mean average precision). Compared to other models—YOLOv3-tiny, YOLOv5, YOLOv8, and YOLOv10—the proposed method achieves higher detection accuracy by 5.9%, 7%, 5.9%, and 5.3%, respectively, and shows improvements in mAP by 5.4%, 5%, 4.8%, and 6.3%. The improved detection algorithm maintains high accuracy while achieving faster inference speed and fewer model parameters. These improvements lay a solid foundation for fire prevention and suppression in cotton collection boxes on cotton pickers.
- Open Access
Research on Fire Detection of Cotton Picker Based on Improved Algorithm
According to the physical characteristics of cotton and the work characteristics of cotton pickers in the field, during the picking process, there is a risk of cotton combustion. The cotton picker working environment is complex, cotton ignition can be hidden, and fire is difficult to detect. Therefore, in this study, we designed an improved algorithm for multi-sensor data fusion; built a cotton picker fire detection system by using infrared temperature sensors, CO sensors, and the upper computer; and proposed a BP neural network model based on improved mutation operator hybrid gray wolf optimizer and particle swarm optimization (MGWO-PSO) algorithm based on the BP neural network model. This algorithm includes the introduction of a mutation operator in the gray wolf algorithm to improve the search ability of the algorithm, and, at the same time, we introduce the PSO algorithm idea. The improved fusion algorithm is used as a learning algorithm to optimize the BP neural network, and the optimized network is used to process and predict the data collected from temperature and gas sensors, which effectively improves the accuracy of fire prediction. The sensor measurements were compared with the actual values to verify the effectiveness of the GWO-PSO-optimized BP neural network model. Once experimentally verified, the improved GWO-PSO algorithm achieves a correlation coefficient R of 0.96929, a prediction accuracy rate of 96.10%, and a prediction error rate of only 3.9%, while the system monitors an accurate early warning rate of 96.07%, and the false alarm and omission rates are both less than 5%. This study can detect cotton picker fires in real time and provide timely warnings, which provides a new method for the accurate detection of fires during the field operation of cotton pickers.
Open AccessResearch on Fire Detection of Cotton Picker Based on Improved Algorithm
According to the physical characteristics of cotton and the work characteristics of cotton pickers in the field, during the picking process, there is a risk of cotton combustion. The cotton picker working environment is complex, cotton ignition can be hidden, and fire is difficult to detect. Therefore, in this study, we designed an improved algorithm for multi-sensor data fusion; built a cotton picker fire detection system by using infrared temperature sensors, CO sensors, and the upper computer; and proposed a BP neural network model based on improved mutation operator hybrid gray wolf optimizer and particle swarm optimization (MGWO-PSO) algorithm based on the BP neural network model. This algorithm includes the introduction of a mutation operator in the gray wolf algorithm to improve the search ability of the algorithm, and, at the same time, we introduce the PSO algorithm idea. The improved fusion algorithm is used as a learning algorithm to optimize the BP neural network, and the optimized network is used to process and predict the data collected from temperature and gas sensors, which effectively improves the accuracy of fire prediction. The sensor measurements were compared with the actual values to verify the effectiveness of the GWO-PSO-optimized BP neural network model. Once experimentally verified, the improved GWO-PSO algorithm achieves a correlation coefficient R of 0.96929, a prediction accuracy rate of 96.10%, and a prediction error rate of only 3.9%, while the system monitors an accurate early warning rate of 96.07%, and the false alarm and omission rates are both less than 5%. This study can detect cotton picker fires in real time and provide timely warnings, which provides a new method for the accurate detection of fires during the field operation of cotton pickers.