PGPatricia A. Gutierrez

Patricia A. Gutierrez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Patricia A. Gutierrez has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MambaX-Net: Dual-input Mamba-enhanced Cross-Attention network for longitudinal prostate MRI segmentation

    by Yovin Yahathugoda, Davide Prezzi, Patricia A. Gutierrez, Piyalitt Ittichaiwong, Vicky Goh, Sebastien Ourselin, Michela Antonelli

  • Open Access

    Combined ADC and T 2 Mapping in the Prostate Using a 3D Reduced FOV Sequence

    by Yannik Ott, Sarah McElroy, Raphael Tomi‐Tricot, Carolyn Horst, Patricia A. Gutierrez, Rahul Khamar, Omar Darwish, Vicky Goh, Radhouene Neji

    Purpose: To develop a 3D reduced FOV sequence for combined ADC and T 2 mapping in the prostate in a single scan. Methods: A 3D ADC and T 2 mapping reduced FOV acquisition is enabled using T 2 and diffusion preparation modules with slab‐selective tip‐down pulses and magnitude stabilizer gradients. Imaging shots are followed by 2D phase navigators for phase correction of diffusion‐prepared shots and dummy RF pulses for T 2 ‐prepared shots, as well as a constant delay to maintain the steady state of the longitudinal magnetization. Mono‐exponential fitting is used for ADC and T 2 mapping. T 2 mapping accuracy was assessed in a phantom against a single‐echo spin‐echo reference. In vivo, the sequence was compared in the prostate of 11 healthy volunteers against a multi‐echo spin‐echo acquisition, as well as standard and reduced FOV (rFOV) single‐shot EPI (ssEPI). Results: In the phantom experiments, T 2 values were not significantly different from the reference single‐echo spin‐echo measurements. ADC values in vivo were not significantly different from those obtained using ssEPI. T 2 values in vivo showed a mean bias of −21.7 ms compared to those obtained using multi‐echo spin‐echo with the first echo discarded in the fitting. The proposed sequence achieved similar overall image quality scores to those of ssEPI and rFOV ssEPI, improved perceived distortion scores, but lower perceived SNR scores. Conclusion: The proposed approach enables 3D reduced FOV, single‐scan ADC, and T 2 mapping with mono‐exponential fitting in the prostate.

  • Future challenges of contrast media in radiology

    by E. Alvarez-Hornia Pérez, C. Carnelli, P.A. Gutierrez, R. González Sánchez, J. Mesa Quesada