Haifa Barakah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haifa Barakah has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Mashael Binhasan
Department of Restorative Dentistry, Collage of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
2 shared publications - Faisal Althobaiti
Intern, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication - Khalid Aljabri
Intern, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication - Nasr Al Maflehi
College of Dentistry, King Saud University, Riyadh, Saudi Arabia
1 shared publication - Nourah Shono
Department of Restorative Dentistry, Collage of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
1 shared publication - Rakan Alyami
Intern, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 22 January 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (1) , 12
Effects of Over-the-Counter Whitening Products on Microhardness, Gloss Retention, and Surface Roughness of Z350 XT Universal Restorative Composite Resin
Objectives: This study investigated the effects of three over-the-counter (OTC) whitening products, whitening pen (WP, Dazzling White Instant Whitening Pen, Dazzling White, Grand Rapids, MI, USA), whitening mouthwash (MW, Colgate Optic White, Colgate-Palmolive, New York, NY, USA), and whitening toothpaste (TP, Crest 3D White, Procter & Gamble, Cincinnati, OH, USA), on the microhardness, gloss retention, and surface roughness of a nanofilled resin composite (Filtek Z350 XT Universal Restorative, 3M ESPE). Methods: Composite resin specimens were prepared and subjected to treatment with WP, MW, or TP. Microhardness, gloss retention, and surface roughness were measured before and after treatment. Data were subjected to statistical analysis, with normality assessed by Shapiro–Wilk testing. Parametric data were summarized as mean ± SD, and differences were evaluated using paired t-tests and one-way ANOVA with a significance level of p ≤ 0. 05. Results: All whitening products significantly altered the tested surface properties. Microhardness decreased in all groups (MD [95% CI]: 2.28 [1.84–2.71] for WP, 5.05 [4.22–5.88] for MW, and 3.09 [2.35–3.83] for TP; p < 0.001), with the greatest reduction observed in the MW group. Gloss retention also declined significantly (MD [95% CI]: 9.52 [6.28–12.76] for WP, 17.97 [14.92–21.01] for MW, and 18.92 [15.64–22.21] for TP; p < 0.001), with TP and MW showing greater loss compared to WP. Surface roughness increased significantly within each group (MD [95% CI]: −0.07 [–0.10 to −0.04] for WP, −0.23 [–0.30 to −0.16] for MW, and −0.25 [–0.38 to −0.13] for TP; p < 0.001), although no significant differences were found among groups in post-treatment values. Conclusions: OTC whitening products adversely affected the optical and mechanical properties of Z350 XT universal composite resin. Whitening MW caused the most pronounced microhardness reduction, while MW and TP induced greater gloss loss than WP. Clinicians should consider the potential impact of whitening products on resin composite restorations when advising patients on their use.
- 22 January 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (1) , 12
Open AccessEffects of Over-the-Counter Whitening Products on Microhardness, Gloss Retention, and Surface Roughness of Z350 XT Universal Restorative Composite Resin
Objectives: This study investigated the effects of three over-the-counter (OTC) whitening products, whitening pen (WP, Dazzling White Instant Whitening Pen, Dazzling White, Grand Rapids, MI, USA), whitening mouthwash (MW, Colgate Optic White, Colgate-Palmolive, New York, NY, USA), and whitening toothpaste (TP, Crest 3D White, Procter & Gamble, Cincinnati, OH, USA), on the microhardness, gloss retention, and surface roughness of a nanofilled resin composite (Filtek Z350 XT Universal Restorative, 3M ESPE). Methods: Composite resin specimens were prepared and subjected to treatment with WP, MW, or TP. Microhardness, gloss retention, and surface roughness were measured before and after treatment. Data were subjected to statistical analysis, with normality assessed by Shapiro–Wilk testing. Parametric data were summarized as mean ± SD, and differences were evaluated using paired t-tests and one-way ANOVA with a significance level of p ≤ 0. 05. Results: All whitening products significantly altered the tested surface properties. Microhardness decreased in all groups (MD [95% CI]: 2.28 [1.84–2.71] for WP, 5.05 [4.22–5.88] for MW, and 3.09 [2.35–3.83] for TP; p < 0.001), with the greatest reduction observed in the MW group. Gloss retention also declined significantly (MD [95% CI]: 9.52 [6.28–12.76] for WP, 17.97 [14.92–21.01] for MW, and 18.92 [15.64–22.21] for TP; p < 0.001), with TP and MW showing greater loss compared to WP. Surface roughness increased significantly within each group (MD [95% CI]: −0.07 [–0.10 to −0.04] for WP, −0.23 [–0.30 to −0.16] for MW, and −0.25 [–0.38 to −0.13] for TP; p < 0.001), although no significant differences were found among groups in post-treatment values. Conclusions: OTC whitening products adversely affected the optical and mechanical properties of Z350 XT universal composite resin. Whitening MW caused the most pronounced microhardness reduction, while MW and TP induced greater gloss loss than WP. Clinicians should consider the potential impact of whitening products on resin composite restorations when advising patients on their use.
- Open Access
Effect of Surface Treatments on Repair Bond Strength of Aged Bulk-Fill Resin Composites
This study evaluated the influence of different surface treatments and composite materials on the microtensile bond strength (μTBS) of repaired aged bulk-fill resin composite restorations, aligning with the principles of minimal intervention dentistry. Seventy-two specimens of bulk-fill resin composite (Tetric EvoCeram) were prepared, sectioned into bars (1 × 1 × 5 mm), and subjected to thermocycling to simulate aging. Specimens were randomly allocated into six groups (n = 12) based on surface treatment and repair material: phosphoric acid etching followed by repair with either Tetric EvoCeram (Group 1) or Filtek Z350 XT (Group 2); diamond bur roughening followed by repair with Tetric EvoCeram (Group 3) or Filtek Z350 XT (Group 4); and air abrasion followed by repair with Tetric EvoCeram (Group 5) or Filtek Z350 XT (Group 6). μTBS testing was performed using a universal testing machine, and failure patterns were examined under a stereomicroscope at 40× magnification. The highest bond strength values were observed in Groups 5 and 6 (air abrasion), followed by Group 3 (diamond bur). Groups 1, 2, and 4 showed significantly lower bond strength values (p < 0.05). No significant differences in failure modes were reported across groups. These findings suggest that air abrasion is a superior surface treatment for repairing aged bulk-fill resin composites, as it significantly enhanced μTBS compared to phosphoric acid etching and diamond bur roughening.
Open AccessEffect of Surface Treatments on Repair Bond Strength of Aged Bulk-Fill Resin Composites
This study evaluated the influence of different surface treatments and composite materials on the microtensile bond strength (μTBS) of repaired aged bulk-fill resin composite restorations, aligning with the principles of minimal intervention dentistry. Seventy-two specimens of bulk-fill resin composite (Tetric EvoCeram) were prepared, sectioned into bars (1 × 1 × 5 mm), and subjected to thermocycling to simulate aging. Specimens were randomly allocated into six groups (n = 12) based on surface treatment and repair material: phosphoric acid etching followed by repair with either Tetric EvoCeram (Group 1) or Filtek Z350 XT (Group 2); diamond bur roughening followed by repair with Tetric EvoCeram (Group 3) or Filtek Z350 XT (Group 4); and air abrasion followed by repair with Tetric EvoCeram (Group 5) or Filtek Z350 XT (Group 6). μTBS testing was performed using a universal testing machine, and failure patterns were examined under a stereomicroscope at 40× magnification. The highest bond strength values were observed in Groups 5 and 6 (air abrasion), followed by Group 3 (diamond bur). Groups 1, 2, and 4 showed significantly lower bond strength values (p < 0.05). No significant differences in failure modes were reported across groups. These findings suggest that air abrasion is a superior surface treatment for repairing aged bulk-fill resin composites, as it significantly enhanced μTBS compared to phosphoric acid etching and diamond bur roughening.
- Open Access
- 10 June 2021
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 33 (8) , 1035-1041
Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units
This study examined the effect of different distances and curing times on the microhardness (VHN) of nanofilled resin-based composite (RBC) restorations polymerized with high-intensity LED LCUs. Seventy-five RBC specimens (2 mm thickness and 5 mm diameter) were fabricated from Tetric-N-Ceram (Ivoclar Vivadent). Each of the 25 specimens was polymerized by means of one of three types of high-intensity LED LCUs: (B) Blue-Phase-G2 (polywave LED, Ivoclar Vivadent), (E) Elipar S10 TM (single-peak, 3 M ESPE), and (P) Planmica Lumion (single-peak, Mectron) at three different distances (0 mm, 2 mm, and 4 mm) at 20 sec, 40 s, and 60 sec. A microhardness tester (NOVA, Innovatest, The Netherlands) was used to measure the VHN from the top and bottom surfaces. Data for VHN were analyzed using mixed ANOVA, followed by post hoc analyses with p-values < 0.05. A significant difference was found in VHN between all three LED LCUs, where (B) specimens had the highest means, followed by (E) and (P). Bottom surface VHN values were reduced significantly (p < 0.05) compared to top surface values in all LCU types. With increasing distances up to 2 mm and 4 mm, VHN values with (E) and (P) were significantly reduced on the top and bottom surfaces (p < 0.05). When the curing times were increased for 40 and 60 sec, the VHN values were significantly improved (p < 0.05). Meanwhile, increasing the distance with (B) did not significantly reduce the VHN. Moreover, increasing the curing times did not significantly improve the VHN of the bottom surfaces. High-intensity LCUs have variable effects on the surface (top/bottom) hardness of Tetric-N-Ceram nanofilled RBC restoration. With increasing distance, VHN was reduced; therefore, compensation with more curing time (2 mm/40 sec and 4 mm/60 sec) is highly recommended with Elipar S10 and Planmica Lumion LCUs to improve the material surface hardness.
- 10 June 2021
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 33 (8) , 1035-1041
Open AccessEffect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units
This study examined the effect of different distances and curing times on the microhardness (VHN) of nanofilled resin-based composite (RBC) restorations polymerized with high-intensity LED LCUs. Seventy-five RBC specimens (2 mm thickness and 5 mm diameter) were fabricated from Tetric-N-Ceram (Ivoclar Vivadent). Each of the 25 specimens was polymerized by means of one of three types of high-intensity LED LCUs: (B) Blue-Phase-G2 (polywave LED, Ivoclar Vivadent), (E) Elipar S10 TM (single-peak, 3 M ESPE), and (P) Planmica Lumion (single-peak, Mectron) at three different distances (0 mm, 2 mm, and 4 mm) at 20 sec, 40 s, and 60 sec. A microhardness tester (NOVA, Innovatest, The Netherlands) was used to measure the VHN from the top and bottom surfaces. Data for VHN were analyzed using mixed ANOVA, followed by post hoc analyses with p-values < 0.05. A significant difference was found in VHN between all three LED LCUs, where (B) specimens had the highest means, followed by (E) and (P). Bottom surface VHN values were reduced significantly (p < 0.05) compared to top surface values in all LCU types. With increasing distances up to 2 mm and 4 mm, VHN values with (E) and (P) were significantly reduced on the top and bottom surfaces (p < 0.05). When the curing times were increased for 40 and 60 sec, the VHN values were significantly improved (p < 0.05). Meanwhile, increasing the distance with (B) did not significantly reduce the VHN. Moreover, increasing the curing times did not significantly improve the VHN of the bottom surfaces. High-intensity LCUs have variable effects on the surface (top/bottom) hardness of Tetric-N-Ceram nanofilled RBC restoration. With increasing distance, VHN was reduced; therefore, compensation with more curing time (2 mm/40 sec and 4 mm/60 sec) is highly recommended with Elipar S10 and Planmica Lumion LCUs to improve the material surface hardness.
- Open Access
- 14 March 2021
- Published by MedCrave Group Kft. in Journal of Dental Health, Oral Disorders & Therapy
- Vol. 12 (2) , 46-50
Esthetic ceramic veneers for spaced anterior teeth utilizing the RED proportion; a case report with three years follow-up
Discrepancy between a large jaw size and small teeth results in a spaced alignment of teeth. Orthodontic treatment to correct such cases will not be sufficient for esthetic results of anterior teeth. Restorative treatment may be the ideal solution to reshape small teeth in well planned proportion to fit the size of the jaw and enhance the appearance of the patient smile. This paper presents the process of restoring spaced anterior teeth with minimally prepared ceramic veneers using the RED proportion.
- 14 March 2021
- Published by MedCrave Group Kft. in Journal of Dental Health, Oral Disorders & Therapy
- Vol. 12 (2) , 46-50
Open AccessEsthetic ceramic veneers for spaced anterior teeth utilizing the RED proportion; a case report with three years follow-up
Discrepancy between a large jaw size and small teeth results in a spaced alignment of teeth. Orthodontic treatment to correct such cases will not be sufficient for esthetic results of anterior teeth. Restorative treatment may be the ideal solution to reshape small teeth in well planned proportion to fit the size of the jaw and enhance the appearance of the patient smile. This paper presents the process of restoring spaced anterior teeth with minimally prepared ceramic veneers using the RED proportion.