ZCZehua Chen

Zehua Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zehua Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Chunliu Zhao

    College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China

    2 shared publications
  • Dongxu Wang

    College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China

    2 shared publications
  • Hailong Wang

    College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China

    2 shared publications
  • Tenghui Mao

    College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China

    2 shared publications
  • Yajuan Zhang

    NMPA Key Laboratory for Biomedical Optics, Zhejiang Institute of Medical Device Supervision and Testing, Hangzhou, China

    2 shared publications
  • Cheng Peng

    College of Optical and Electronic Technology, China Jiliang University, Hangzhou, China

    1 shared publication

Latest Publications

  • The Effect of Length and Curvature on Quantum-Enhanced Temperature Sensing in a Fiber-Based Sagnac Loop

    by Hailong Wang, Zehua Chen, Tenghui Mao, Dongxu Wang, Cheng Peng, Yajuan Zhang, Chunliu Zhao

    In this work, we theoretically proposed and experimentally demonstrated enhanced effect of prior curvature precondition on temperature sensing in a quantum-enhanced sensing system, which is constructed by combining an all-fiber two-mode squeezed light source and a Sagnac loop. By choosing the prior optimum length and curvature of polarization-maintaining fiber inside Sagnac loop, both signal-to-noise ratio and sensitivity can be effectively enhanced. The experimental results are summarized as follows. Signal-to-noise ratio is enhanced by the factor of 0.38 dB under balanced measurement condition. Under unbalanced measurement condition, the enhanced factors with regard to sensing depth are 0.22 dB and 2.34 dB for classical double-channel light source and two-mode squeezed light source, respectively. With the support of curvature precondition, the sensing depth of the former one 15.62 dB is enhanced to 31.49 dB of the latter one by an enhanced factor of 15.87 dB, which is larger than 13.75 dB in the absence of curvature precondition, this enhanced effect still exists in the temperature sensitivity (0.982 dB/°C<1.134 dB/°C) and signal-to-noise ratio (0.54 dB<1.7 dB). These results confirm the potential prospects of using the cross effects from other physical quantities to enhance temperature sensing in a quantum-enhanced sensing system.


  • Quantum-Enhanced Strain and Curvature Sensing Based on a Birefringent Fiber Sagnac Interferometer

    by Hailong Wang, Zehua Chen, Siyuan Ma, Dongxu Wang, Tenghui Mao, Yajuan Zhang, Chunliu Zhao

    In this work, the combination of an all-fiber two-mode squeezed state light source and Sagnac interferometer for the experimental realization of a quantum-enhanced strain and curvature sensor is presented here. The former can offer intensity-correlated twin beams, whose intensity difference noise is beyond standard quantum limit. The latter can be prepared by splicing a polarization-maintaining fiber between two standard single-mode fibers. Using the intensity interrogation method tracing the intensity variation of the sensing signal beam, we can obtain the following quantum-enhanced experimental results. In the strain sensing, signal-to-noise ratio (SNR) is enhanced by a maximal factor of 1.54 dB compared with the corresponding classical strategy under balanced measurement condition. Under unbalanced measurement condition, SNR and the sensitivity are enhanced by the maximal factors of 1.39 dB and 0.026 dB/μϵ respectively compared with the corresponding classical counterpart. In the curvature sensing, balanced measurement condition can offer a maximal factor of 1.31 dB SNR enhancement, unbalanced measurement condition will bring the maximal factors of 1.36 dB and 3.31 dB/m−1 respectively enhancement in SNR and sensitivity. These results demonstrate the feasibility of the combination of all-fiber non-classical light source and various fiber-based structures as the strain and curvature sensors for many applications that demands sub-poissonian precise measurements.