Ahmed Kadhim Hussein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmed Kadhim Hussein has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Lioua Kolsi
Department of Mechanical Engineering College of Engineering University of Ha'il Ha'il City Saudi Arabia
2 shared publications - Mohammed Abdulrahman Almeshaal
College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia
2 shared publications A A Shbeeb
College of Engineering, Babylon University, Iraq
1 shared publicationA. Aguilar-Arevalo
1 shared publicationA. Sher
1 shared publication- Alaa Abbas Mahdi
College of Engineering, Babylon University, 51002, Iraq
1 shared publication
Latest Publications
- Open Access
- 20 January 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1073
Measurement of the response function of the PIENU calorimeter
- 20 January 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1073
Open AccessMeasurement of the response function of the PIENU calorimeter
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1067 (1) , 012089
Effects of supply Diffuser Shape on Air Age and Human Comfort in an Office with Displacement Ventilation and Chilled Ceiling System in Hot and Dry climate
In recent years, the need to provide a clean environment in enclosed places has drawn increasing levels of attention due to the spread of epidemics and viruses across the world. Chilled ceilings with displacement ventilation represent promising technology. The combined ventilation system has not yet been used in Iraqi buildings, then it’s a good starting point for study the performance of this system in Iraq-Hilla city climate (hot and dry climate). An office room with a combined ventilation system was simulated using AIRPAK software. Indoor air age, air temperature distribution, CO2 concentration and thermal efficiency were estimated numerically. During the simulation process, the effects of two different supply diffuser shapes (one way rectangular diffuser and semicircle diffuser) were compared to investigated the effect of supply diffuser shape on air age and thermal environment in hot and dry climate (passed on peak summer temperatures in Hilla city). Three tests were performed for each case based on changing the load treated by the chilled ceiling as (25%, 50% and 80%) respect to total cooling load and represented (26, 53, 85W/m2) respectively based on floor area. The temperature of chilled ceiling surface varied as (21.5, 19 and 16°C) and the air supply temperature similarly varied (19, 22, and 24.5 °C) respectively at constant air flowrate of (0.045m3/s). The results of the tests found that the effect of diffuser shape on the local age of air decreased with height, the maximum difference between two cases at the 0.1m level was about 49s while at 2.25m level it was only about 11s. The air exchange efficiency for the CC/DV system using a semicircle diffuser in the predetermined office space was higher by an average of 8.5% as compared with a similar system using a rectangular diffuser; this differential reduced about 3% at each increase in portion of cooling load treated by the chilled ceiling, however.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1067 (1) , 012089
Open AccessEffects of supply Diffuser Shape on Air Age and Human Comfort in an Office with Displacement Ventilation and Chilled Ceiling System in Hot and Dry climate
In recent years, the need to provide a clean environment in enclosed places has drawn increasing levels of attention due to the spread of epidemics and viruses across the world. Chilled ceilings with displacement ventilation represent promising technology. The combined ventilation system has not yet been used in Iraqi buildings, then it’s a good starting point for study the performance of this system in Iraq-Hilla city climate (hot and dry climate). An office room with a combined ventilation system was simulated using AIRPAK software. Indoor air age, air temperature distribution, CO2 concentration and thermal efficiency were estimated numerically. During the simulation process, the effects of two different supply diffuser shapes (one way rectangular diffuser and semicircle diffuser) were compared to investigated the effect of supply diffuser shape on air age and thermal environment in hot and dry climate (passed on peak summer temperatures in Hilla city). Three tests were performed for each case based on changing the load treated by the chilled ceiling as (25%, 50% and 80%) respect to total cooling load and represented (26, 53, 85W/m2) respectively based on floor area. The temperature of chilled ceiling surface varied as (21.5, 19 and 16°C) and the air supply temperature similarly varied (19, 22, and 24.5 °C) respectively at constant air flowrate of (0.045m3/s). The results of the tests found that the effect of diffuser shape on the local age of air decreased with height, the maximum difference between two cases at the 0.1m level was about 49s while at 2.25m level it was only about 11s. The air exchange efficiency for the CC/DV system using a semicircle diffuser in the predetermined office space was higher by an average of 8.5% as compared with a similar system using a rectangular diffuser; this differential reduced about 3% at each increase in portion of cooling load treated by the chilled ceiling, however.
- Open Access
- 9 May 2019
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 138 (2) , 1443-1460
MHD mixed convection in an inclined cavity containing adiabatic obstacle and filled with Cu–water nanofluid in the presence of the heat generation and partial slip
- 9 May 2019
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 138 (2) , 1443-1460
Open AccessMHD mixed convection in an inclined cavity containing adiabatic obstacle and filled with Cu–water nanofluid in the presence of the heat generation and partial slip
- Open Access
- 1 January 2019
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 460
Study of heat and mass transfer control inside channel partially filled with a porous medium using nanofluids
The steady mixed convection of heat and mass transfer inside and outside a porous vertical wall is numerically studied. The porous wall, placed in a vertical channel, contains a solid phase, a nanofluid phase (Water-Al2O3 or Water-Cu) and gas phase. The effect of several physical quantities such as nanoparticle volume fraction, ambient temperature and initial nanofluid saturation on heat and mass transfer were investigated. Results reveal that the temperature of porous medium is decreased considerably with nanoparticle volume fraction. It has been also found that the heat and mass transfer are dramatically reduced using Water-Alumina nanofluid when compared with pure water.
- 1 January 2019
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 460
Open AccessStudy of heat and mass transfer control inside channel partially filled with a porous medium using nanofluids
The steady mixed convection of heat and mass transfer inside and outside a porous vertical wall is numerically studied. The porous wall, placed in a vertical channel, contains a solid phase, a nanofluid phase (Water-Al2O3 or Water-Cu) and gas phase. The effect of several physical quantities such as nanoparticle volume fraction, ambient temperature and initial nanofluid saturation on heat and mass transfer were investigated. Results reveal that the temperature of porous medium is decreased considerably with nanoparticle volume fraction. It has been also found that the heat and mass transfer are dramatically reduced using Water-Alumina nanofluid when compared with pure water.
- Open Access
- 1 March 2016
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 55 (1) , 169-186
Heatline visualization of natural convection heat transfer in an inclined wavy cavities filled with nanofluids and subjected to a discrete isoflux heating from its left sidewall
- 1 March 2016
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 55 (1) , 169-186
Open AccessHeatline visualization of natural convection heat transfer in an inclined wavy cavities filled with nanofluids and subjected to a discrete isoflux heating from its left sidewall
- 12 December 2011
- Published by Society of Petroleum Engineers (SPE)
High Performance Drilling Fluids Addressing the Challenges in Drilling Shallow Viscous Oil Reservoir in Kuwait
The primary challenge in drilling shallow depth viscous oil formation in Kuwait is to achieve gauged holes while drilling in unconsolidated friable sand-shale alteration. Gauged holes are the key for the production techniques used in this field, where cement channeling and perforation effectiveness are of main concern. To achieve this, a specific drilling fluid design was necessary. Laboratory tests and extensive research were initiated to customize the drilling fluid parameters and wellbore hydraulics necessary to achieve the primary drilling objectives. The drilling fluid design goal was to provide enhanced clay inhibition for the clay strikes, gave good lubricity and low friction coefficient to ensure the smooth drilling and tripping operations in a gauged hole profile. Additionally, the environmental advantage of avoiding the generation of drilling waste with high chloride content was achieved, therefore contributing to KOC’s HS&E goals. Fluids viscosity and hydraulics were designed in high profile to remain completely in laminar flow while drilling to minimize washout occurrence and maximize hole cleaning at low circulation rates (140 – 150 GPM) without the use of regular sweeps. The customized drilling parameters and practices, in addition to the knowledge gained from the laboratory testing phase, were transferred to the field. This resulted in proved success with more than hundred and twenty five perfect gauge holes
- 12 December 2011
- Published by Society of Petroleum Engineers (SPE)
High Performance Drilling Fluids Addressing the Challenges in Drilling Shallow Viscous Oil Reservoir in Kuwait
The primary challenge in drilling shallow depth viscous oil formation in Kuwait is to achieve gauged holes while drilling in unconsolidated friable sand-shale alteration. Gauged holes are the key for the production techniques used in this field, where cement channeling and perforation effectiveness are of main concern. To achieve this, a specific drilling fluid design was necessary. Laboratory tests and extensive research were initiated to customize the drilling fluid parameters and wellbore hydraulics necessary to achieve the primary drilling objectives. The drilling fluid design goal was to provide enhanced clay inhibition for the clay strikes, gave good lubricity and low friction coefficient to ensure the smooth drilling and tripping operations in a gauged hole profile. Additionally, the environmental advantage of avoiding the generation of drilling waste with high chloride content was achieved, therefore contributing to KOC’s HS&E goals. Fluids viscosity and hydraulics were designed in high profile to remain completely in laminar flow while drilling to minimize washout occurrence and maximize hole cleaning at low circulation rates (140 – 150 GPM) without the use of regular sweeps. The customized drilling parameters and practices, in addition to the knowledge gained from the laboratory testing phase, were transferred to the field. This resulted in proved success with more than hundred and twenty five perfect gauge holes