ABA.T. Begyan

A.T. Begyan

*This is an algorithmically generated author record based on publicly available information.

A.T. Begyan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental study of the primary stability of dental implants using different osteotomy protocols

    by A.A. Kulakov, A.T. Begyan, E.M. Chernovol, S.N. Ermolev, I.D. Rumyantsev

    Objective. To evaluate the influence of an undersized drilling protocol on primary stability of «A2» dental implants in low-density D3-D4 bone using a comprehensive diagnostic approach. Materials and Methods. An in vitro study was performed on two porcine vertebral bone macro-specimens and «Sawbones» polyurethane blocks of four densities. Density was assessed by shadow and echo-pulsed ultrasonographic densitometry. Two experimental models were created; in each, six implants of the A2 system were placed with dimensions of 3.5×6.6 mm (A6.6) and 3.5×11 mm (A11). In all cases, an undersized drilling protocol with subcrestal placement (1—2 mm) was applied. The osteotomy bed was prepared with a 2 mm pilot drill and a three-fluted bur, followed by a conical reamer. Implant placement was performed using the «W&H Implantmed Plus» physiodispenser with torque curve registration. Primary stability was assessed by resonance frequency analysis (ISQ) using the «Osstell Beacon»; implant position was verified by CBCT (Axeos, Dentsply Sirona). Statistics included mean, standard deviation (SD), 95% confidence intervals (CI) and coefficient of variation (CV). Results. In polyurethane blocks: shadow densitometry 952—1344 m/s; echo-pulsed ultrasonographic densitometry 1870—2674 m/s. In porcine bone, trabecular bone was 1408—1500 m/s and cortical up to 2303 m/s; the model corresponded to D3-D4 density. In group «A11», torque at placement was 31.67±4.80 N·cm, ISQ=81.92±1.12, torque at removal 37.00±4.43 N·cm; in «A6.6» -23.33±3.61; 71.83±7.22 and 22.33±6.19, respectively. Differences were statistically significant Conclusion. The undersized drilling protocol provides high primary stability in low-density D3-D4 bone. Ultrasonic densitometry may serve as an additional objective method for assessing bone quality and selecting an appropriate drilling protocol to predict primary stability. A comprehensive diagnostic approach supports optimization of the surgical protocol and reduces the risk of early postoperative complications.

  • Model selection for determination of primary stability of dental implants in experimental studies

    by A.A. Kulakov, A.T. Begyan

    Objective: systematic review of literature on the pre-clinical studies of dental implantation in different models by finding out data about primary stability. Materials and methods. PubMed, NCBI, Wiley Online Library, MBPI, Elibrary systems were used for search. Results. Based on the literature review of the described animal species dogs have the most similar bone structure to humans but their usage is complicated by ethics and law reasons. They are next followed by rabbits with a frequency of use of 35%. Small ruminants’, pigs’ and mini-pigs’ bones are close to human bones and their use is not ethically complicated. The mini-pig model allows assessing bone and soft tissue status of the previously surgical treated area for a sufficient time. Polyurethane blocks have been proposed as an artificial substitute for in vitro simulation in dental implant placement. The advantage of this material is its homogeneous structure. Conclusion. Small ruminants, pigs and mini-pigs are the most optimal for preclinical studies on dental implantation.