Weifeng Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weifeng Peng has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Xiangwu Yan
North China Electric Power University
3 shared publicationsChen Shao
North China Electric Power University
2 shared publications- Shufeng Dong
College of Electrical Engineering, Zhejiang University, Hangzhou, Zhejiang, China
2 shared publications - Chao Chen
State Grid Zhejiang Electric Power Co., Ltd. Electric Power Science Research Institute, Hangzhou 310014, China
1 shared publication - Chen Shao
Key Laboratory of Distributed Energy Storage and Micro-Grid of Hebei Province, North China Electric Power University, Baoding 071003, China
1 shared publication - Cheng Xie
State Grid Zhejiang Electric Power Co., Ltd. Electric Power Science Research Institute, Hangzhou 310014, China
1 shared publication
Latest Publications
- 7 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. PP (19493029) , 1-16
Wind Speed Scenario Generation under Typhoon Conditions via Prediction-Anchored Diffusion
Wind speed sequences under typhoon conditions exhibit complex spatio-temporal non-stationary characteristics, making it challenging for existing methods to control key features. This paper proposes a method for generating conditional wind speed scenarios based on a prediction-anchored diffusion model (PADM). First, a typhoon-aware time-series graph neural network (TA-TGNN) is developed, which constructs typhoon-aware adjacency matrices through trajectory similarity, temporal decay, and intensity similarity to characterize non-stationary dependencies. Second, a dual-dimensional adaptive attention mechanism (DDAM) is introduced, combining phase detectors and physical constraints to adaptively select and fuse key information across temporal and feature dimensions, thereby enhancing phase-aware prediction. Finally, PADM leverages deterministic prediction results as anchors and integrates hierarchical conditional encoding with temporal awareness to generate physically consistent and diverse wind speed scenarios. Case studies demonstrate that the proposed method accurately reproduces the structural characteristics of typhoon wind speeds and captures variations under different conditions, while maintaining stability and consistency across various hyperparameter settings.
- 7 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. PP (19493029) , 1-16
Wind Speed Scenario Generation under Typhoon Conditions via Prediction-Anchored Diffusion
Wind speed sequences under typhoon conditions exhibit complex spatio-temporal non-stationary characteristics, making it challenging for existing methods to control key features. This paper proposes a method for generating conditional wind speed scenarios based on a prediction-anchored diffusion model (PADM). First, a typhoon-aware time-series graph neural network (TA-TGNN) is developed, which constructs typhoon-aware adjacency matrices through trajectory similarity, temporal decay, and intensity similarity to characterize non-stationary dependencies. Second, a dual-dimensional adaptive attention mechanism (DDAM) is introduced, combining phase detectors and physical constraints to adaptively select and fuse key information across temporal and feature dimensions, thereby enhancing phase-aware prediction. Finally, PADM leverages deterministic prediction results as anchors and integrates hierarchical conditional encoding with temporal awareness to generate physically consistent and diverse wind speed scenarios. Case studies demonstrate that the proposed method accurately reproduces the structural characteristics of typhoon wind speeds and captures variations under different conditions, while maintaining stability and consistency across various hyperparameter settings.
- Open Access
Photovoltaic Hosting Capacity Assessment of Distribution Networks Considering Source–Load Uncertainty
With the continuous expansion of distributed photovoltaic (PV) integration, the hosting capacity of distribution networks has become a critical issue in power system planning and operation. Under varying meteorological and load fluctuation conditions, traditional assessment methods often face adaptability and uncertainty handling challenges. To enhance the practical applicability and accuracy of hosting capacity evaluations, this paper proposes a PV hosting capacity assessment model that incorporates source–load uncertainty and constructs an alternative scenario optimization evaluation framework driven by target-oriented scenario generation. The model considers system constraints and employs the sparrow search algorithm (SSA) to optimize the maximum PV hosting capacity. On the source side, PV output scenarios with temporal characteristics are generated based on the mapping relationship between meteorological factors and PV power. On the load side, historical data are employed to extract fluctuation ranges and to introduce random perturbations to simulate load uncertainty. In addition, a PV power scenario generation method based on the Wasserstein generative adversarial network with gradient penalty (WGAN-GP) is proposed, integrating physical-data dual-driven strategies to enhance the physical consistency of generated data, while incorporating a target-driven weighted sampling mechanism to improve its learning ability for key features. Case studies verify that the proposed method demonstrates strong adaptability and accuracy under varying meteorological and load conditions.
Open AccessPhotovoltaic Hosting Capacity Assessment of Distribution Networks Considering Source–Load Uncertainty
With the continuous expansion of distributed photovoltaic (PV) integration, the hosting capacity of distribution networks has become a critical issue in power system planning and operation. Under varying meteorological and load fluctuation conditions, traditional assessment methods often face adaptability and uncertainty handling challenges. To enhance the practical applicability and accuracy of hosting capacity evaluations, this paper proposes a PV hosting capacity assessment model that incorporates source–load uncertainty and constructs an alternative scenario optimization evaluation framework driven by target-oriented scenario generation. The model considers system constraints and employs the sparrow search algorithm (SSA) to optimize the maximum PV hosting capacity. On the source side, PV output scenarios with temporal characteristics are generated based on the mapping relationship between meteorological factors and PV power. On the load side, historical data are employed to extract fluctuation ranges and to introduce random perturbations to simulate load uncertainty. In addition, a PV power scenario generation method based on the Wasserstein generative adversarial network with gradient penalty (WGAN-GP) is proposed, integrating physical-data dual-driven strategies to enhance the physical consistency of generated data, while incorporating a target-driven weighted sampling mechanism to improve its learning ability for key features. Case studies verify that the proposed method demonstrates strong adaptability and accuracy under varying meteorological and load conditions.
- Open Access
- 15 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 19 (1)
An online loop closing current calculation method for complex distribution networks considering source and load uncertainties
To address the challenges posed by frequent source and load fluctuations in existing loop closing current calculation methods, this paper proposes an online loop closing current calculation method that considers source and load uncertainties. First, a dual‐stack dynamic monitoring system is utilized to obtain real‐time voltage and current variations before and after disturbances. Second, Thevenin's theorem is employed to build an equivalent model of the distribution network, simplifying the complex network into a combination of an independent voltage source and a series impedance. Then, the steady‐state loop closing current is calculated based on the open‐circuit voltage and equivalent impedance at both sides of the loop closing point. Next, the optimal frequency method is applied to determine the equivalent impedance and attenuation time constant at a specific frequency, achieving accurate calculation of the transient loop closing current. Finally, simulations are conducted to model the fluctuations in distributed generation and load, analysing the steady‐state and transient loop closing currents. The simulation results demonstrate that the proposed method accurately captures the effects of source and load fluctuations on the loop closing current in dynamic environments, with minimal calculation error, indicating its high practicality.
- 15 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 19 (1)
Open AccessAn online loop closing current calculation method for complex distribution networks considering source and load uncertainties
To address the challenges posed by frequent source and load fluctuations in existing loop closing current calculation methods, this paper proposes an online loop closing current calculation method that considers source and load uncertainties. First, a dual‐stack dynamic monitoring system is utilized to obtain real‐time voltage and current variations before and after disturbances. Second, Thevenin's theorem is employed to build an equivalent model of the distribution network, simplifying the complex network into a combination of an independent voltage source and a series impedance. Then, the steady‐state loop closing current is calculated based on the open‐circuit voltage and equivalent impedance at both sides of the loop closing point. Next, the optimal frequency method is applied to determine the equivalent impedance and attenuation time constant at a specific frequency, achieving accurate calculation of the transient loop closing current. Finally, simulations are conducted to model the fluctuations in distributed generation and load, analysing the steady‐state and transient loop closing currents. The simulation results demonstrate that the proposed method accurately captures the effects of source and load fluctuations on the loop closing current in dynamic environments, with minimal calculation error, indicating its high practicality.
- 2 April 2024
- Published by Springer Nature
- p. 796-809
Voltage Regulation Method for a Rotary Power Flow Controller Based on the Impedance Regulation Principle
- 2 April 2024
- Published by Springer Nature
- p. 796-809
Voltage Regulation Method for a Rotary Power Flow Controller Based on the Impedance Regulation Principle
- Open Access
- 26 March 2024
- Published by Wiley
Comprehensive Compensation Method for Co-phase Power Supply in Electrified Railways Based on V/v Transformer and Single-phase Rotating Var Compensator
To solve the problem of negative-sequence and reactive power in electrified railway, this paper proposes a comprehensive compensation method based on V/v transformers and electromagnetic single-phase var compensator (ESVC) for co-phase power supply. First, based on the principles of static var generator (SVG) and single-phase rotary phase shifting transformer (SRPST), the topology and model of ESVC have been established, and the compensation mechanism has been analyzed. Second, the topological structure and mathematical model of co-phase power comprehensive compensation device (CPCD) are put forward based on the principles of V/v transformers and ESVC, and the operation mode of CPCD in multiple scenarios is designed. Then the strategy of CPCD with double closed loop control is analyzed: corresponding compensation mode is selected according to negative-sequence unbalance degree and expected power factor value. In this strategy, the compensated current output by ESVC is taken as the quantity of external loop control, and the rotation angle of ESVC is taken as the quantity of internal loop control to realize double-closed loop control of CPCD. Finally, the comprehensive CPCD compensation model is built on the simulation platform and validated the accuracy of the mathematical model and the effectiveness of the control strategy.
- 26 March 2024
- Published by Wiley
Open AccessComprehensive Compensation Method for Co-phase Power Supply in Electrified Railways Based on V/v Transformer and Single-phase Rotating Var Compensator
To solve the problem of negative-sequence and reactive power in electrified railway, this paper proposes a comprehensive compensation method based on V/v transformers and electromagnetic single-phase var compensator (ESVC) for co-phase power supply. First, based on the principles of static var generator (SVG) and single-phase rotary phase shifting transformer (SRPST), the topology and model of ESVC have been established, and the compensation mechanism has been analyzed. Second, the topological structure and mathematical model of co-phase power comprehensive compensation device (CPCD) are put forward based on the principles of V/v transformers and ESVC, and the operation mode of CPCD in multiple scenarios is designed. Then the strategy of CPCD with double closed loop control is analyzed: corresponding compensation mode is selected according to negative-sequence unbalance degree and expected power factor value. In this strategy, the compensated current output by ESVC is taken as the quantity of external loop control, and the rotation angle of ESVC is taken as the quantity of internal loop control to realize double-closed loop control of CPCD. Finally, the comprehensive CPCD compensation model is built on the simulation platform and validated the accuracy of the mathematical model and the effectiveness of the control strategy.
- Open Access
- 11 January 2023
- Published by Wiley
An accurate power control strategy for electromagnetic rotary power controllers
With the rapid development of active distribution networks, the “petal”-type distribution network has become the mainstream power supply structure. To ensure the safe and reliable power supply of a distribution system, power control methods for active distribution networks should be further studied. An electromagnetic rotary power flow controller (RPFC) is a feasible solution for active distribution network power control. However, when testing the effectiveness of the PQ decoupled control method for RPFC based on instantaneous reactive power theory, difficulties were encountered with the synchronous control of the rotor position angle of two rotating-phase transformers, and the accuracy of power control was unsatisfactory. Given this condition, PQ control is improved in three ways. First, the system periodic oscillation problem is solved via variable speed control. Second, the servo motor–rotary phase-shifting transformer synchronous rotation scheme is designed, reducing power control error and improving stability. The overshoot phenomenon in power control is improved using the variable domain fuzzy proportional–integral adaptive method. Experimental results show that the proposed advanced control scheme exhibits good dynamic and static performance in power control scenarios and achieves effective improvement of RPFC.
- 11 January 2023
- Published by Wiley
Open AccessAn accurate power control strategy for electromagnetic rotary power controllers
With the rapid development of active distribution networks, the “petal”-type distribution network has become the mainstream power supply structure. To ensure the safe and reliable power supply of a distribution system, power control methods for active distribution networks should be further studied. An electromagnetic rotary power flow controller (RPFC) is a feasible solution for active distribution network power control. However, when testing the effectiveness of the PQ decoupled control method for RPFC based on instantaneous reactive power theory, difficulties were encountered with the synchronous control of the rotor position angle of two rotating-phase transformers, and the accuracy of power control was unsatisfactory. Given this condition, PQ control is improved in three ways. First, the system periodic oscillation problem is solved via variable speed control. Second, the servo motor–rotary phase-shifting transformer synchronous rotation scheme is designed, reducing power control error and improving stability. The overshoot phenomenon in power control is improved using the variable domain fuzzy proportional–integral adaptive method. Experimental results show that the proposed advanced control scheme exhibits good dynamic and static performance in power control scenarios and achieves effective improvement of RPFC.