Perla E. Medina-Corral
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Perla E. Medina-Corral has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alejandrina Bautista Jacobo
Universidad de Sonora
1 shared publication - Aracely Angulo-Molina
Universidad de Sonora
1 shared publication - Benedetto Schiavo
Instituto de Geofísica, Universidad Nacional Autónoma de México, Mexico City 04510, Mexico
1 shared publication - Diana Meza-Figueroa
Department of Geology, University of Sonora, Hermosillo, Mexico
1 shared publication - Enrique Castilla-Arias
Universidad Vizcaya de las Américas
1 shared publication - Fernanda Delgado-Gaytán
Universidad Vizcaya de las Américas
1 shared publication
Latest Publications
- 11 August 2026
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (12) , 517
Particle characterization in an urban synthetic turf: insights into turf and vehicular wear
- 11 August 2026
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (12) , 517
Particle characterization in an urban synthetic turf: insights into turf and vehicular wear
- Open Access
- 20 January 2025
- Published by JURUFRA SL in Retos
- Vol. 64, 394-402
Precision of body composition estimation from commercial bioelectrical impedance analysis devices in male Mexican soccer players
Introduction: Bioelectrical Impedance Analysis (BIA) estimates fat-free mass in athletes; however, its precision can be affected by technical errors, biological variability, and fluctuations in hydration levels. Objective: to evaluate the technical and biological measurement errors in the estimation of body composition in male Mexican soccer players using commercial BIA devices. Methodology: A quantitative, comparative, correlational longitudinal cohort study was conducted including 31 male soccer players. Participants underwent three assessments across two consecutive laboratory visits: two measurements during the first visit (technical error) and one during the second (biological error). Fat-free mass (FFM) estimated using Omron HBF-306, Tanita BC-514 and Omron HBF-545 BIA devices. To determine the technical error and biological error of measurements, the root means square error (RMSE) and least significant change (LSC). Results: HBF-514 provided the lowest FFM values across the devices. The body fat estimations from BC-545, significant differences were observed in day-to-day assessment (p<0.05). Reliability analysis revealed a RMSE values of 0.52 kg, 0.24 kg and 0.26 kg and LSC values of 2.36 kg, 1.92 kg and 1.68 kg for FFM using HBF-306, BC-545 and HBF-514 respectively. Discussion: The precision of BIA devices was lower compared to other studies conducted on general populations, suggesting that athletes’ characteristics may affect the reliability of these devices. Conclusions: The HBF-306C showed greater variability compared to the other devices while the HBF-514 demonstrates the highest day-to-day reliability, making it a valuable tool for tracking BC in soccer players.
- 20 January 2025
- Published by JURUFRA SL in Retos
- Vol. 64, 394-402
Open AccessPrecision of body composition estimation from commercial bioelectrical impedance analysis devices in male Mexican soccer players
Introduction: Bioelectrical Impedance Analysis (BIA) estimates fat-free mass in athletes; however, its precision can be affected by technical errors, biological variability, and fluctuations in hydration levels. Objective: to evaluate the technical and biological measurement errors in the estimation of body composition in male Mexican soccer players using commercial BIA devices. Methodology: A quantitative, comparative, correlational longitudinal cohort study was conducted including 31 male soccer players. Participants underwent three assessments across two consecutive laboratory visits: two measurements during the first visit (technical error) and one during the second (biological error). Fat-free mass (FFM) estimated using Omron HBF-306, Tanita BC-514 and Omron HBF-545 BIA devices. To determine the technical error and biological error of measurements, the root means square error (RMSE) and least significant change (LSC). Results: HBF-514 provided the lowest FFM values across the devices. The body fat estimations from BC-545, significant differences were observed in day-to-day assessment (p<0.05). Reliability analysis revealed a RMSE values of 0.52 kg, 0.24 kg and 0.26 kg and LSC values of 2.36 kg, 1.92 kg and 1.68 kg for FFM using HBF-306, BC-545 and HBF-514 respectively. Discussion: The precision of BIA devices was lower compared to other studies conducted on general populations, suggesting that athletes’ characteristics may affect the reliability of these devices. Conclusions: The HBF-306C showed greater variability compared to the other devices while the HBF-514 demonstrates the highest day-to-day reliability, making it a valuable tool for tracking BC in soccer players.