MTMansour Taleshi

Mansour Taleshi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mansour Taleshi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Tip-of-the-pen: Error profiles and kinematic signatures of orthographic retrieval difficulty in Chinese handwriting

    by Lili Tian, Mansour Taleshi, Timo Saarinen, Ivan Vujaklija, Mia Liljeström

    The growing reliance on digital typing has led to a decline in handwriting skills. This problem is particularly salient in Chinese, where writers must retrieve complex character forms from memory rather than rely on transparent sound-to-spelling mappings. Although handwriting difficulties among Chinese writers have been reported, the specific error types and kinematic signatures of this decline remain unclear. To bridge this gap, the present study investigated the typology of handwriting errors and their corresponding kinematic characteristics. Kinematic and writing data were recorded from 37 native Chinese speakers during a handwriting task. Handwriting errors were manually annotated and categorized using a data-driven error annotation scheme. Linear mixed-effects models were used to analyze eight temporal, spatial, pressure, and movement-dynamics measures. Results showed an overall writing accuracy of 0.76, with recall failure being the most frequent error type, followed by non-real (or pseudo-) and non-target characters. Relative to correct writing, recall failure exhibited a delayed writing onset, prolonged writing duration, and reduced mean pen pressure and velocity. Non-real differed on all measures except mean pen pressure, whereas non-target characters showed delayed onset, longer duration, reduced total pressure, more acceleration peaks, and higher normalized jerk, but comparable velocity and mean pressure. These kinematic patterns suggest increased cognitive demands and reduced writing efficiency during erroneous character production. We therefore propose extending the interactive models of handwriting by introducing the recursive dynamics among cognitive, linguistic, and motor processes as a framework for understanding how writing attrition affects character production.

  • Open Access

    Sensitivity of Non-Invasive Motor-Unit-Based Gesture Recognition to Signal Degradation

    by Mansour Taleshi, Dennis Yeung, Francesco Negro, Ivan Vujaklija

    The information encoded by motor units has been successfully harnessed to establish high-fidelity human-machine interfaces (HMI). However, the sensitivity of these interfaces using high-density surface electromyography decomposition, a prevalent method for observing motor unit behaviour, to signal degradations commonly encountered in practical settings remains unexplored. Here, we investigated the effects of additive white Gaussian noise (WGN), channel loss, and electrode shift on pseudo-real-time MU-driven motion classification. Across six wrist movements by 13 participants, we evaluated the performance of two classifiers: linear discriminant analysis (LDA) and deep neural networks (DNN), under different noise conditions. The results indicate that spatial perturbations, including channel loss and electrode shift, significantly affected classification accuracy, with LDA being more susceptible than DNN. Conversely, under intense signal noise (WGN with 5 dB SNR), LDA outperformed DNN, and its simplicity potentially provides greater robustness in a challenging environment. Hence, application-specific signal processing considerations are required depending on the target HMI application. IMPACT STATEMENT: Perturbation severely impairs non-invasive motor-unit-based gesture recognition. High signal fidelity and robust system design are essential for practical human-machine interaction.

  • Open Access

    Effects of Spatial and Signal-Imposed Noises on Motor Unit Decomposition

    by Mansour Taleshi, Dennis Yeung, Francesco Negro, Ivan Vujaklija

    High-density surface electromyography (HD-sEMG) decomposition offers insights into the neural drive through observation of individual motor units (MUs). However, ensuring that this method remains reliable under real-world signal degradations is crucial for its broader application. Therefore, we investigated the impact of three commonly modeled signal degradations on convolutive blind-source-separation (BSS) MU decomposition. 192 HD-sEMG channels were recorded from the forearm muscles of thirteen healthy participants during six wrist movements. Three broad categories of perturbation were introduced, including additive white Gaussian noise (WGN), channel loss, and electrode shift. These perturbations were chosen to mimic challenges encountered in practice, such as ambient electrical noise, electrode failures, and sensor displacement in order to test the MU decomposition algorithms sensitivity. Then, the effects of perturbations on the quantity and quality of extracted MUs and neural drive estimation were assessed. Under non-perturbed conditions, an average of 179 ± 40 MUs were extracted. Severe global WGN significantly reduced extracted MUs by approximately 81%. In contrast, more localized WGN, or channel loss as high as 15%, and electrode shift had minimal impact, with reductions in the number of MU decomposed being less than 6%. Reconstruction of neural drive through smoothed cumulative spike trains was significantly impaired by global WGN, thus leading to increased root mean square error when compared to conditions, while localized perturbations had negligible effects. Therefore, the BSS-based MU decomposition methods seem to be robust against localized noise, channel loss, and minor electrode shifts but are vulnerable to global additive noise. These results highlight the importance of carefully applying MU decomposition approaches in practical settings, maintaining high SNRs in EMG recordings, and preprocessing noise treatment to specific MU-decomposition needs.

  • Open Access

    Impact of Noise on Deep Learning-Based Pseudo-Online Gesture Recognition with High-Density EMG

    by Mansour Taleshi, Dennis Yeung, Minh Dinh Trong, Francesco Negro, Stéphane Deny, Ivan Vujaklija

    Deep neural network (DNN)–based approaches have demonstrated high accuracy in surface electromyography (sEMG)–driven gesture recognition under controlled conditions. However, estimation performance is known to degrade substantially when exposed to perturbations commonly encountered in the real-world. Here, we investigate the impact of typical noises on an autoencoder augmented recurrent neural network gesture estimator driven by engineered features and feature sets. High-density sEMG (HD-sEMG) signals offering rich information particularly suited to DNN-based algorithms were collected from thirteen participants performing wrist movements. Three types of synthetic disturbances were introduced: additive white Gaussian noise (WGN), channel loss, and electrode shift. Results indicate that when using amplitude-based features (specifically, the root mean square value and the mean absolute value), the estimator maintains robust performance under increasing WGN and channel loss, whereas its performance deteriorates markedly with features reflecting signal dynamics and fluctuations, like slope sign changes and zero crossings. Under electrode shift conditions, employing a combined feature set enhances the classifier’s resilience. Importantly, the degree of performance degradation depends on both the type and intensity of the noise. These findings confirm the need for noise-resilient architectures in order to achieve practical, everyday sEMG-driven human-machine interfaces. Clinical Relevance: Quantifying the sensitivity of sEMG-based gesture classifiers to noise can help clinicians tailor electrode placement and training and ultimately decrease user frustration and improve the acceptance of assistive devices.


  • Open Access

    Observing changes in motoneuron characteristics following distorted sensorimotor input via blood flow restriction

    by Mansour Taleshi, Franziska Bubeck, Pascal Brunner, Leonardo Gizzi, Ivan Vujaklija

    To improve our understanding of how acute blood flow restriction (BFR) intervention affects neuromechanical function and motor unit characteristics, we applied high-density surface electromyography on the abductor digiti minimi muscle during isometric trapezoidal and sinusoidal precision force tracking tasks. Although BFR increased discomfort, it minimally affected force tracking performance; however, it did alter the underlying motor unit behavior. These findings further enhance our understanding of the neural mechanisms underlying BFR.