HMHiromu Morishita

Hiromu Morishita

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hiromu Morishita has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EUS Shear Wave Elastography for Assessing Pancreatic Fibrosis: An Exploratory Study of Its Histological Correlation

    by Akiya Nakahata, Yasunobu Yamashita, Fumiyoshi Kojima, Yuto Sugihara, Tomokazu Ishihara, Hiromu Morishita, Takahiro Shishimoto, Yuki Kawaji, Takashi Tamura, Masahiro Itonaga, et al.

    Objectives: Endoscopic ultrasound shear wave elastography (EUS‐SWE) enables quantitative, noninvasive assessment of tissue elasticity. However, the association between EUS‐SWE and pancreatic histology remains unclear. This study aimed to investigate the utility of EUS‐SWE for predicting pancreatic fibrosis by comparing it with histological findings of resected specimens. Methods: Patients who underwent EUS‐SWE before pancreatectomy between October 2019 and October 2024 were retrospectively enrolled. SWE was performed near the surgical resection margin, and shear wave velocity (Vs, m/s) was measured. The number of EUS morphological findings according to the Rosemont classification was obtained. Histological findings were assessed using quantitative analysis and grading analysis. The association between EUS‐SWE or the number of EUS morphological findings and histological findings, as well as the diagnostic performance of EUS‐SWE and EUS morphological findings for predicting histological fibrosis at predefined fibrosis thresholds (≥ 5%, ≥ 10%, ≥ 15%, and ≥ 20%) was evaluated. Results: Thirty‐four patients were included. Vs correlated significantly with quantitative fibrosis ( ρ = 0.73, p < 0.001), but not with fatty infiltration and inflammation. The number of EUS morphological findings correlated only with fibrosis grade ( ρ = 0.35, p = 0.041). EUS‐SWE had higher diagnostic accuracy than EUS morphological findings for predicting histological fibrosis at all thresholds (91.2%, 88.2%, 82.4%, and 88.2% vs. 55.9%, 67.6%, 55.9%, and 50.0%, respectively). Conclusions: EUS‐SWE may serve as a quantitative, noninvasive method for evaluating pancreatic fibrosis. Trial Registration: UMIN ID: 000058397

  • Experimental Evaluation of Novel Two‐Dimensional Endoscopic Ultrasound Shear Wave Elastography: A Phantom‐Based Study

    by Yasunobu Yamashita, Akiya Nakahata, Hiroki Yamada, Hirofumi Yamazaki, Hiromu Morishita, Tomokazu Ishihara, Yuto Sugihara, Takahiro Shishimoto, Yuki Kawaji, Takashi Tamura, et al.

    Point shear wave elastography (SWE) can indicate tissue elasticity using absolute values, but it remains difficult to determine which areas are suitable for measurement. Recently, two‐dimensional endoscopic ultrasound SWE (2D‐EUS‐SWE), which allows visual assessment of appropriate measurement locations, has become possible. However, it remains unclear how to set the measurement and color regions of interest (ROIs) appropriately. This study aimed to evaluate the optimal ROI settings for 2D‐EUS‐SWE under various measurement conditions with phantom. Two types of commercially available elasticity phantoms were used to evaluate 2D‐EUS‐SWE. The conditions were set for five parameters: measurement ROI size, color ROI size, color ROI depth, degree of probe pressure, and color ROI angle. Measurements were performed 10 times for each setting. In a tumor model, the color ROI was set over or within the tumor. Reproducibility and reliability were then evaluated for each setting. Setting the color ROI at a depth range of 1–3 cm was found to be appropriate. The measurements were possible regardless of the color and measurement ROI sizes. When the color ROI was positioned directly below (0°), tilting it up to 45° had no effect on the measurement. In the tumor model, measurements were possible regardless of the color ROI size. In addition to clarifying the optimal condition settings, the present findings indicate that 2D‐EUS‐SWE is an accurate and reliable method for performing measurements using EUS. However, this was conducted under phantom conditions, and future clinical evaluation is necessary.

  • Open Access

    Emergent treatment using balloon-assisted ERCP versus EUS-guided drainage for acute cholangitis in patients with surgically altered anatomy

    by Takahiro Shishimoto, Masahiro Itonaga, Reiko Ashida, Yasunobu Yamashita, Yuki Kawaji, Takashi Tamura, Hiromu Morishita, Akiya Nakahata, Yuto Sugihara, Tomokazu Ishihara, et al.

    Takahiro Shishimoto, Masahiro Itonaga, Reiko Ashida, Yasunobu Yamashita, Yuki Kawaji, Takashi Tamura, Hiromu Morishita, Akiya Nakahata, Yuto Sugihara, Tomokazu Ishihara, and Masayuki Kitano. Int J Gastrointest Interv 2025;14:2-8. https://doi.org/10.18528/ijgii240070