Prabha Prakash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Prabha Prakash has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Abraham Samuel Babu
Department of Physiotherapy, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India
1 shared publication Ansar Ereath Beeran
Bioceramics Laboratory, Sree Chitra Tirunal Institute for Medical Sciences & Technology, Poojappura, India
1 shared publication- Baby Chakrapani Pulikkaparambil Sasidharan
Centre for Neuroscience, Department of Biotechnology, Cochin University of Science and Technology, Kochi, India
1 shared publication Beena Mol
Department of Physics, Cochin University of Science and Technology, Cochin, India
1 shared publication- Danavath Nagendra
Department of Critical Care Medicine, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India
1 shared publication - Dinker Ramananda Pai
Department of Surgery, Medical Simulation Centre, Mahatma Gandhi Medical College and Research Institute, Sri Balaji Vidyapeeth, Puducherry, India
1 shared publication
Latest Publications
- Open Access
- 13 April 2026
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 19 (1) , 97
Unravelling technical domain barriers and non-technical skill barriers among interprofessional teams during in-hospital cardiac arrest: a questionnaire-based survey
Background: In spite of focused cardiopulmonary resuscitation (CPR) training, the in-hospital cardio-pulmonary resuscitation (CPR) performance often remains suboptimal, due to technical domain barriers and non-technical skill (NTS) barriers. We aimed to determine the technical domain and NTS barriers encountered by the in-hospital interprofessional (IP) CPR resuscitation teams through a cross-sectional, quantitative, analytical survey, and to determine whether a poor NTS score alone is associated with non-adherence to high-quality CPR. Methods: A validated questionnaire was developed comprising 17 items on technical domain barriers and 9 on the NTS barrier domain. A web-based Likert-scale questionnaire was administered to assess perception-based barriers among 400 IP team members across healthcare settings in India, focusing on technical domain barriers and NTS domain barriers. IP members with at least 1 year of work experience, hands-on CPR training, and in-hospital CPR experience were recruited. Results: There were 32.75% doctors, 29.75% nurses, 24% respiratory therapists, 10.25% emergency technicians, and 2.25% ICU technicians. The logistic regression analysis revealed that only five items independently predicted a poor technical domain score: inability to identify cardiac rhythm, non-working defibrillator, unavailability of a supraglottic airway device, unavailability of a correct-size laryngoscope blade, and a delay in loading medications. Five NTS items independently predicted a poor NTS score: lack of clear instructions from the team leader, lack of awareness of the dynamic nature of resuscitation, lack of closed-loop communication, lack of assigned tasks completed by a team member, and lack of knowledge sharing among team members. A poor NTS score is associated with perceived non-adherence to high-quality CPR (Chi-Square test, p-value < 0.001). Conclusion: Both NTS barriers and technical domain barriers were associated with perceived non-adherence to high-quality CPR. Trial registration: Clinical Trial Registry of India CTRI/2025/05/086727 registered on 13/05/2025.
- 13 April 2026
- Published by Springer Nature in International Journal of Emergency Medicine
- Vol. 19 (1) , 97
Open AccessUnravelling technical domain barriers and non-technical skill barriers among interprofessional teams during in-hospital cardiac arrest: a questionnaire-based survey
Background: In spite of focused cardiopulmonary resuscitation (CPR) training, the in-hospital cardio-pulmonary resuscitation (CPR) performance often remains suboptimal, due to technical domain barriers and non-technical skill (NTS) barriers. We aimed to determine the technical domain and NTS barriers encountered by the in-hospital interprofessional (IP) CPR resuscitation teams through a cross-sectional, quantitative, analytical survey, and to determine whether a poor NTS score alone is associated with non-adherence to high-quality CPR. Methods: A validated questionnaire was developed comprising 17 items on technical domain barriers and 9 on the NTS barrier domain. A web-based Likert-scale questionnaire was administered to assess perception-based barriers among 400 IP team members across healthcare settings in India, focusing on technical domain barriers and NTS domain barriers. IP members with at least 1 year of work experience, hands-on CPR training, and in-hospital CPR experience were recruited. Results: There were 32.75% doctors, 29.75% nurses, 24% respiratory therapists, 10.25% emergency technicians, and 2.25% ICU technicians. The logistic regression analysis revealed that only five items independently predicted a poor technical domain score: inability to identify cardiac rhythm, non-working defibrillator, unavailability of a supraglottic airway device, unavailability of a correct-size laryngoscope blade, and a delay in loading medications. Five NTS items independently predicted a poor NTS score: lack of clear instructions from the team leader, lack of awareness of the dynamic nature of resuscitation, lack of closed-loop communication, lack of assigned tasks completed by a team member, and lack of knowledge sharing among team members. A poor NTS score is associated with perceived non-adherence to high-quality CPR (Chi-Square test, p-value < 0.001). Conclusion: Both NTS barriers and technical domain barriers were associated with perceived non-adherence to high-quality CPR. Trial registration: Clinical Trial Registry of India CTRI/2025/05/086727 registered on 13/05/2025.
- Open Access
- 25 August 2021
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 32 (9) , 1-14
Radio frequency plasma assisted surface modification of Fe3O4 nanoparticles using polyaniline/polypyrrole for bioimaging and magnetic hyperthermia applications
Surface modification of superparamagnetic Fe3O4nanoparticles using polymers (polyaniline/polypyrrole) was done by radio frequency (r.f.) plasma polymerization technique and characterized by XRD, TEM, TG/DTA and VSM. Surface-passivated Fe3O4nanoparticles with polymers were having spherical/rod-shaped structures with superparamagnetic properties. Broad visible photoluminescence emission bands were observed at 445 and 580 nm for polyaniline-coated Fe3O4and at 488 nm for polypyrrole-coated Fe3O4. These samples exhibit good fluorescence emissions with L929 cellular assay and were non-toxic. Magnetic hyperthermia response of Fe3O4and polymer (polyaniline/polypyrrole)-coated Fe3O4was evaluated and all the samples exhibit hyperthermia activity in the range of 42–45 °C. Specific loss power (SLP) values of polyaniline and polypyrrole-coated Fe3O4nanoparticles (5 and 10 mg/ml) exhibit a controlled heat generation with an increase in the magnetic field.
- 25 August 2021
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 32 (9) , 1-14
Open AccessRadio frequency plasma assisted surface modification of Fe3O4 nanoparticles using polyaniline/polypyrrole for bioimaging and magnetic hyperthermia applications
Surface modification of superparamagnetic Fe3O4nanoparticles using polymers (polyaniline/polypyrrole) was done by radio frequency (r.f.) plasma polymerization technique and characterized by XRD, TEM, TG/DTA and VSM. Surface-passivated Fe3O4nanoparticles with polymers were having spherical/rod-shaped structures with superparamagnetic properties. Broad visible photoluminescence emission bands were observed at 445 and 580 nm for polyaniline-coated Fe3O4and at 488 nm for polypyrrole-coated Fe3O4. These samples exhibit good fluorescence emissions with L929 cellular assay and were non-toxic. Magnetic hyperthermia response of Fe3O4and polymer (polyaniline/polypyrrole)-coated Fe3O4was evaluated and all the samples exhibit hyperthermia activity in the range of 42–45 °C. Specific loss power (SLP) values of polyaniline and polypyrrole-coated Fe3O4nanoparticles (5 and 10 mg/ml) exhibit a controlled heat generation with an increase in the magnetic field.