Thiago de Oliveira Dorigão
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thiago de Oliveira Dorigão has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Helton Luiz Aparecido Defino
Universidade de São Paulo
5 shared publications - Matheus Pippa Defino
Universidade de São Paulo, Brazil
5 shared publications - Gabriel Mattos Goes
Universidade de São Paulo, Brazil
2 shared publications - Rian Souza Vieira
Universidade de São Paulo, Brazil
2 shared publications - Denylson Sanches Fernandes
Universidade de São Paulo, Brazil
1 shared publication - Flávio Emanuel Gonçalves de Abreu
Médico Residente em Ortopedia e Traumatologia, Departamento de Ortopedia e Anestesiologia, Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo (HC-FMRP-USP) 14040-906 Ribeirão Preto - SP, Brasil
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 25 (1)
Analysis of the Limitations of Robotic Systems in Spine Surgery
Objective: To analyze the limitations and complications of using a robotic system in spinal surgeries during the learning curve. Methods: To evaluate the results of the application of 415 pedicle screws in 67 patients undergoing spinal surgery in which the robotic system was used. Recording time, fluoroscopy time, intraoperative radiation dose, implant accuracy, abandonment of the robotic system, problems with the system program, and clinical complications were evaluated. Results: Discrepant values were observed in recording time in 9 (13.43%) patients, in fluoroscopy time in 3 (4.47%), and in intraoperative radiation dose in 8 (11.94%). Malpositioning (vertebral pedicle wall rupture > 2 mm) occurred in 3.5% of the implants evaluated in the axial plane and 0.48% in the sagittal plane. No abandonment of the robotic system was observed. Neurological deficit was observed in one patient. Conclusions: The robotic system demonstrated effectiveness and precision in implant placement, but system limitations were observed, mainly related to the acquisition of good-quality images for system registration. Level of evidence IV; Case Series.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 25 (1)
Open AccessAnalysis of the Limitations of Robotic Systems in Spine Surgery
Objective: To analyze the limitations and complications of using a robotic system in spinal surgeries during the learning curve. Methods: To evaluate the results of the application of 415 pedicle screws in 67 patients undergoing spinal surgery in which the robotic system was used. Recording time, fluoroscopy time, intraoperative radiation dose, implant accuracy, abandonment of the robotic system, problems with the system program, and clinical complications were evaluated. Results: Discrepant values were observed in recording time in 9 (13.43%) patients, in fluoroscopy time in 3 (4.47%), and in intraoperative radiation dose in 8 (11.94%). Malpositioning (vertebral pedicle wall rupture > 2 mm) occurred in 3.5% of the implants evaluated in the axial plane and 0.48% in the sagittal plane. No abandonment of the robotic system was observed. Neurological deficit was observed in one patient. Conclusions: The robotic system demonstrated effectiveness and precision in implant placement, but system limitations were observed, mainly related to the acquisition of good-quality images for system registration. Level of evidence IV; Case Series.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 25 (1)
Less invasive surgery for the treatment of idiopathic scoliosis in adolescents
Objective: To present the results of the surgical treatment of adolescent idiopathic scoliosis (AIS) using a less invasive technique. Methods: Ten patients diagnosed with AIS underwent surgical treatment using a less invasive approach (bipolar technique) and were followed for 24 months. They were evaluated using radiographic parameters (Cobb angle and thoracic kyphosis) and clinical parameters (SRS-22 questionnaire, blood transfusion, and complications). Results: Correction in both the coronal and sagittal planes showed statistically significant differences compared to preoperative values. Four domains (function/activity, self-image, mental health, and satisfaction) as well as the overall SRS-22 score demonstrated statistically significant improvement at the 24-month postoperative evaluation. No intraoperative or postoperative blood transfusions were required in any patient. Rod breakage and pedicle screw loosening were observed in two patients, who required surgical revision. Conclusions: Correction of AIS using a less invasive technique allowed deformity correction with reduced surgical morbidity and resulted in improvement of radiographic and clinical parameters at the 24-month postoperative evaluation. Level of evidence IV; Case Series.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 25 (1)
Open AccessLess invasive surgery for the treatment of idiopathic scoliosis in adolescents
Objective: To present the results of the surgical treatment of adolescent idiopathic scoliosis (AIS) using a less invasive technique. Methods: Ten patients diagnosed with AIS underwent surgical treatment using a less invasive approach (bipolar technique) and were followed for 24 months. They were evaluated using radiographic parameters (Cobb angle and thoracic kyphosis) and clinical parameters (SRS-22 questionnaire, blood transfusion, and complications). Results: Correction in both the coronal and sagittal planes showed statistically significant differences compared to preoperative values. Four domains (function/activity, self-image, mental health, and satisfaction) as well as the overall SRS-22 score demonstrated statistically significant improvement at the 24-month postoperative evaluation. No intraoperative or postoperative blood transfusions were required in any patient. Rod breakage and pedicle screw loosening were observed in two patients, who required surgical revision. Conclusions: Correction of AIS using a less invasive technique allowed deformity correction with reduced surgical morbidity and resulted in improvement of radiographic and clinical parameters at the 24-month postoperative evaluation. Level of evidence IV; Case Series.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 24 (4)
Unilateral fixation in the treatment of metastatic lesions of the spine
Objective: To evaluate the surgical outcome of patients with spinal metastases who underwent unilateral fixation using a pedicle fixation system. Methods: Seventeen patients with metastatic spinal lesions underwent surgical treatment for metastatic spinal lesions. Unilateral fixation of the affected vertebral segment was performed using a pedicle fixation system, as well as unilateral fixation of two vertebrae cranial and caudal to the affected vertebra. Decompression of the nerve structures and reconstruction of the anterior spine using vertebral spacers were performed according to the individual needs of each patient. Patients were evaluated using clinical and radiological parameters. Results: Pain, assessed using the visual analog scale (VAS), showed a statistically significant reduction in pre- and postoperative scores. Implant-related complications were observed in three patients, tumor recurrence in two patients, and postoperative infection in one patient. Conclusion: unilateral fixation of the spine using pedicle fixation systems provided mechanical stability and statistical reduction in pain scores, reduced the morbidity of the surgical procedure and presented a low rate of postoperative complications. Level of Evidence IV; Case Series.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 24 (4)
Open AccessUnilateral fixation in the treatment of metastatic lesions of the spine
Objective: To evaluate the surgical outcome of patients with spinal metastases who underwent unilateral fixation using a pedicle fixation system. Methods: Seventeen patients with metastatic spinal lesions underwent surgical treatment for metastatic spinal lesions. Unilateral fixation of the affected vertebral segment was performed using a pedicle fixation system, as well as unilateral fixation of two vertebrae cranial and caudal to the affected vertebra. Decompression of the nerve structures and reconstruction of the anterior spine using vertebral spacers were performed according to the individual needs of each patient. Patients were evaluated using clinical and radiological parameters. Results: Pain, assessed using the visual analog scale (VAS), showed a statistically significant reduction in pre- and postoperative scores. Implant-related complications were observed in three patients, tumor recurrence in two patients, and postoperative infection in one patient. Conclusion: unilateral fixation of the spine using pedicle fixation systems provided mechanical stability and statistical reduction in pain scores, reduced the morbidity of the surgical procedure and presented a low rate of postoperative complications. Level of Evidence IV; Case Series.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 24 (2)
MORPHOMETRIC PARAMETERS OF THE AXIS RELATED TO INTRALAMINAR FIXATION
Objective: To evaluate the morphometric parameters of the C2 (axis) lamina related to the intralaminar fixation technique and compare the dimensions between sexes. Methods: Descriptive anatomical study of 59 C2 vertebrae from cadavers (30 male and 29 female). Seven morphometric parameters were bilaterally measured by four independent examiners using a standard analog caliper. Statistical analysis included normality tests, t-Student, Mann-Whitney, and Kruskal-Wallis. Results: Morphometric measurements showed significant differences between sexes, with greater values in males (p<0.05). Lamina thickness was less than 4 mm in 25.20% of cases, more frequently in females. Conclusions: Intralaminar fixation of the axis must account for anatomical variations, particularly in females. Lamina thickness below 4 mm limits the safe use of 3.5 mm screws, emphasizing the need for detailed preoperative assessment. Level of Evidence IV; Descriptive Anatomical Observational Study.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 24 (2)
Open AccessMORPHOMETRIC PARAMETERS OF THE AXIS RELATED TO INTRALAMINAR FIXATION
Objective: To evaluate the morphometric parameters of the C2 (axis) lamina related to the intralaminar fixation technique and compare the dimensions between sexes. Methods: Descriptive anatomical study of 59 C2 vertebrae from cadavers (30 male and 29 female). Seven morphometric parameters were bilaterally measured by four independent examiners using a standard analog caliper. Statistical analysis included normality tests, t-Student, Mann-Whitney, and Kruskal-Wallis. Results: Morphometric measurements showed significant differences between sexes, with greater values in males (p<0.05). Lamina thickness was less than 4 mm in 25.20% of cases, more frequently in females. Conclusions: Intralaminar fixation of the axis must account for anatomical variations, particularly in females. Lamina thickness below 4 mm limits the safe use of 3.5 mm screws, emphasizing the need for detailed preoperative assessment. Level of Evidence IV; Descriptive Anatomical Observational Study.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in SANAMED
- Vol. 19 (3) , 367-372
Minimally invasive bipolar fixation for the treatment of neuromuscular scoliosis: Miladi's technique
This paper presents the minimally invasive bipolar technique, also known as Miladi's technique, for the treatment of neuromuscular scoli-osis. This approach involves bipolar spinal fixation extending from T1 to the pelvis. Proximal fixation is achieved using laminar and pedicular hooks configured as claws, while distal fixation employs iliosacral connectors and screws. The proximal and distal anchors are connected by a bilateral double-rod sliding construct, allowing for correction of spinal curvature and pelvic obliquity. This technique demonstrates reduced morbidity and complication rates compared to traditional methods.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in SANAMED
- Vol. 19 (3) , 367-372
Open AccessMinimally invasive bipolar fixation for the treatment of neuromuscular scoliosis: Miladi's technique
This paper presents the minimally invasive bipolar technique, also known as Miladi's technique, for the treatment of neuromuscular scoli-osis. This approach involves bipolar spinal fixation extending from T1 to the pelvis. Proximal fixation is achieved using laminar and pedicular hooks configured as claws, while distal fixation employs iliosacral connectors and screws. The proximal and distal anchors are connected by a bilateral double-rod sliding construct, allowing for correction of spinal curvature and pelvic obliquity. This technique demonstrates reduced morbidity and complication rates compared to traditional methods.