Zheren Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zheren Zhu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Congyu Liao
Department of Radiology and Biomedical Imaging University of California San Francisco California USA
2 shared publications Kawin Setsompop
Department of Radiology Stanford University Stanford California USA
2 shared publicationsNan Wang
Department of Radiology Stanford University Stanford California USA
2 shared publications- Xiaozhi Cao
Department of Radiology Stanford University Stanford California USA
2 shared publications - Yang Yang
Department of Radiology and Biomedical Imaging University of California San Francisco California USA
2 shared publications - Zhitao Li
Department of Radiology Northwestern University Evanston Illinois USA
2 shared publications
Latest Publications
- 20 August 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 114
Report Supervision
- 30 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2611-2626
In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner
Purpose: To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess. Methods: This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation. Results: Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo. Conclusion: Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.
- 30 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2611-2626
In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner
Purpose: To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess. Methods: This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation. Results: Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo. Conclusion: Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.
- 15 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 41-58
Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T
Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal‐to‐noise ratio is limited by the field strength and k‐space sampling speed is limited by a lower specification gradient system. Methods: We adapted the three‐dimensional spiral projection imaging MR fingerprinting approach to 0.55T scanners, with additional features incorporated to improve the image quality of quantitative brain and musculoskeletal imaging, including (i) improved k‐space sampling efficiency, (ii) Cramér‐Rao lower bound optimized flip‐angle pattern for specified T 1 and T 2 at 0.55 T, (iii) gradient trajectory correction, (iv) attention‐based denoising, and (v) motion estimation and correction. Results: The proposed MRF acquisition and reconstruction framework can provide high‐quality 1.2‐mm isotropic whole‐brain quantitative maps and 1‐mm isotropic knee quantitative maps, each acquired in 4.5 min. The proposed method was validated in both phantom and in vivo brain and knee studies. Conclusion: By proposing novel methods and integrating advanced techniques, we achieved high‐isotropic‐resolution MRF on a 0.55T scanner, demonstrating enhanced efficiency, motion resilience, and quantitative accuracy.
- 15 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 41-58
Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T
Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal‐to‐noise ratio is limited by the field strength and k‐space sampling speed is limited by a lower specification gradient system. Methods: We adapted the three‐dimensional spiral projection imaging MR fingerprinting approach to 0.55T scanners, with additional features incorporated to improve the image quality of quantitative brain and musculoskeletal imaging, including (i) improved k‐space sampling efficiency, (ii) Cramér‐Rao lower bound optimized flip‐angle pattern for specified T 1 and T 2 at 0.55 T, (iii) gradient trajectory correction, (iv) attention‐based denoising, and (v) motion estimation and correction. Results: The proposed MRF acquisition and reconstruction framework can provide high‐quality 1.2‐mm isotropic whole‐brain quantitative maps and 1‐mm isotropic knee quantitative maps, each acquired in 4.5 min. The proposed method was validated in both phantom and in vivo brain and knee studies. Conclusion: By proposing novel methods and integrating advanced techniques, we achieved high‐isotropic‐resolution MRF on a 0.55T scanner, demonstrating enhanced efficiency, motion resilience, and quantitative accuracy.