Gabriel Brewster
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gabriel Brewster has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Albert Y. Shih
NASA Goddard Space Flight Center 20771 Greenbelt MD USA
2 shared publications - Andreas Zoglauer
Space Sciences Laboratory, UC Berkeley, 7 Gauss Way, University of California, Berkeley, CA 94720, USA
2 shared publications - Aravind B. Valluvan
Department of Astronomy and Astrophysics, UC San Diego, La Jolla, CA, USA
2 shared publications - Jarred M. Roberts
Department of Astronomy & Astrophysics University of California San Diego 9500 Gilman Drive La Jolla 92093 CA USA
2 shared publications - Joanna M. Szornel
Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, USA
2 shared publications - John A. Tomsick
Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720-7450, USA
2 shared publications
Latest Publications
- 2 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (5) , 1800-1808
In-Orbit Spectral Calibration Prospects for the COSI Space Telescope
The Compton Spectrometer and Imager is an upcoming NASA space telescope in the MeV range. COSI’s primary science goals include precisely mapping positron annihilation and nuclear line emissions in the Milky Way galaxy through Compton imaging. This relies on our ability to maintain COSI’s spectral performance over its mission lifetime. Changes in the detectors’ gain characteristics over time will result in inaccurate measurement of astrophysical gamma-ray energies. Moreover, observations from past MeV telescopes and proton-beam experiments have shown that radiation damage in space causes photopeak shifts and spectral line broadening. These necessitate a plan for regular, in-orbit spectral calibration. In this study, we demonstrate a method to monitor and recalibrate the COSI detectors using background line emissions produced by the space radiation environment. We employ Monte Carlo simulations of particle background and show that strong background lines arise from nuclear excitation of COSI’s detectors (germanium) and cryostat (aluminum) materials. These span COSI’s entire bandwidth for single-site interactions and can be used to monitor the effects of radiation damage and gain shifts every 12 hours at the full instrument level and every 16 days at the individual detector level. Methods developed by Pike et al. [1, 2] to correct the effects of hole trapping and gain characteristics can then be applied to recover the original spectral performance. These results inform COSI’s telemetry requirements for calibration and housekeeping data, and rule out the need for an onboard radioactive calibration source, which would have increased the complexity of the spacecraft.
- 2 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (5) , 1800-1808
In-Orbit Spectral Calibration Prospects for the COSI Space Telescope
The Compton Spectrometer and Imager is an upcoming NASA space telescope in the MeV range. COSI’s primary science goals include precisely mapping positron annihilation and nuclear line emissions in the Milky Way galaxy through Compton imaging. This relies on our ability to maintain COSI’s spectral performance over its mission lifetime. Changes in the detectors’ gain characteristics over time will result in inaccurate measurement of astrophysical gamma-ray energies. Moreover, observations from past MeV telescopes and proton-beam experiments have shown that radiation damage in space causes photopeak shifts and spectral line broadening. These necessitate a plan for regular, in-orbit spectral calibration. In this study, we demonstrate a method to monitor and recalibrate the COSI detectors using background line emissions produced by the space radiation environment. We employ Monte Carlo simulations of particle background and show that strong background lines arise from nuclear excitation of COSI’s detectors (germanium) and cryostat (aluminum) materials. These span COSI’s entire bandwidth for single-site interactions and can be used to monitor the effects of radiation damage and gain shifts every 12 hours at the full instrument level and every 16 days at the individual detector level. Methods developed by Pike et al. [1, 2] to correct the effects of hole trapping and gain characteristics can then be applied to recover the original spectral performance. These results inform COSI’s telemetry requirements for calibration and housekeeping data, and rule out the need for an onboard radioactive calibration source, which would have increased the complexity of the spacecraft.
- Open Access
- 24 January 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 59 (1) , 1-16
Characterizing hole trap production due to proton irradiation in germanium cross-strip detectors
We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, $$[n\sigma ]_\textrm{h}$$ , follows a linear relationship with the proton fluence, $$F_\textrm{p}$$ , with a slope of $$(5.4\pm 0.4)\times 10^{-11}\,\mathrm {cm/p^{+}}$$ . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.- 24 January 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 59 (1) , 1-16
Open AccessCharacterizing hole trap production due to proton irradiation in germanium cross-strip detectors
We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, $$[n\sigma ]_\textrm{h}$$ , follows a linear relationship with the proton fluence, $$F_\textrm{p}$$ , with a slope of $$(5.4\pm 0.4)\times 10^{-11}\,\mathrm {cm/p^{+}}$$ . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.