Malikeh Pour Ebrahim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Malikeh Pour Ebrahim has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mehmet Rasit Yuce
Electrical and Computer System Engineering, Monash University, Clayton, VIC, Australia
3 shared publications - Adam Glowacz
Department of Automatic Control and Robotics, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Science and Technology, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
1 shared publication - André Luiz Andreoli
Department of Electrical Engineering, São Paulo State University, Bauru 17033-360, SP, Brazil
1 shared publication - Bruno Albuquerque de Castro
Department of Electrical Engineering, School of Engineering, So Paulo State University (UNESP), Bauru, Brazil
1 shared publication - Fatemeh Heydari
Department of Anesthesiology, Faculty of Medicine, Sari Imam Khomeini Hospital, Mazandaran University of Medical Sciences, Sari, Iran
1 shared publication - Guilherme Beraldi Lucas
Department of Electrical Engineering, São Paulo State University, Bauru 17033-360, SP, Brazil
1 shared publication
Latest Publications
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (8) , 8876-8886
A Low-Frequency Portable Continuous Wave Radar System for Vital Signs Monitoring
Modalities for continuous real-time heart rate and respiration rate monitoring is a crucial diagnostic tool, specifically in the early detection of potential health risks and timely intervention to reduce fatality. A low-frequency chest-wearable continuous wave radar device ( RDR–SENSE ) has been designed and developed for continuous monitoring of heart rate and respiration rate. The developed RDR–SENSE device detects the periodic movements in the human thoracic region associated with cardio-pulmonary activities. The chest-wearable low-power RDR–SENSE device has been designed and manufactured in small size (5cm x 5cm). Five volunteers’ cardio-pulmonary activities were collected using the device in five different respiratory scenarios, and a precise signal processing algorithm was applied to derive their heart rate and respiration rate data. The measured data were compared with reference signals to evaluate the RDR–SENSE’s performance. The measured heart and respiration rates were highly promising in terms of accuracy. The mean absolute error was one beat per minute for the heart rate and 0.75 respiration per minute for the respiration rate. The root mean square error was 1.55 BPM for the heart rate and 1.25 RPM for the respiration rate. The developed RDR–SENSE explores the prospects of a chest-wearable, compact, low-frequency radar device for accurate continuous heart rate and respiration rate measurements during seated activities that resemble daily-life study or work.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (8) , 8876-8886
A Low-Frequency Portable Continuous Wave Radar System for Vital Signs Monitoring
Modalities for continuous real-time heart rate and respiration rate monitoring is a crucial diagnostic tool, specifically in the early detection of potential health risks and timely intervention to reduce fatality. A low-frequency chest-wearable continuous wave radar device ( RDR–SENSE ) has been designed and developed for continuous monitoring of heart rate and respiration rate. The developed RDR–SENSE device detects the periodic movements in the human thoracic region associated with cardio-pulmonary activities. The chest-wearable low-power RDR–SENSE device has been designed and manufactured in small size (5cm x 5cm). Five volunteers’ cardio-pulmonary activities were collected using the device in five different respiratory scenarios, and a precise signal processing algorithm was applied to derive their heart rate and respiration rate data. The measured data were compared with reference signals to evaluate the RDR–SENSE’s performance. The measured heart and respiration rates were highly promising in terms of accuracy. The mean absolute error was one beat per minute for the heart rate and 0.75 respiration per minute for the respiration rate. The root mean square error was 1.55 BPM for the heart rate and 1.25 RPM for the respiration rate. The developed RDR–SENSE explores the prospects of a chest-wearable, compact, low-frequency radar device for accurate continuous heart rate and respiration rate measurements during seated activities that resemble daily-life study or work.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (8) , 8899-8908
A Novel Approach Applied to Transient Short-Circuit Diagnosis in TIMs by Piezoelectric Sensors, PCA, and Wavelet Transform
Non-invasive fault diagnosis of three-phase induction motors (TIM) is widely used in industrial applications to ensure the integrity of processes. Among different types of TIM failures, transient inter-turn short circuits (ITSCs) are incipient stator winding faults characterized as short circuits between two or more turns of the coils, that can lead the winding to progressive deterioration, and consequently, the TIM to total failure. In this context, this article proposes a novel approach by using piezoelectric transducers, which performs the transient ITSC detection, phase identification, and magnitude classification by using the Acoustic Emission (AE) technique. To accomplish this analysis, a new statistical index based on the cross-correlation function was proposed to detect the ITSC and classify its magnitude. Besides, Wavelet Transform and Principal Component Analysis (PCA) stood out as promising tools to identify which phase was affected by the short circuits. A TIM was subjected to ITSCs and the experimental results showed that the proposed algorithm successfully performed the transient ITSC detection, phase identification, and evolution classification. Additionally, this work improve the capabilities of traditional AE systems, since no AE signal processing algorithm has ever been proposed for a comprehensive diagnosis of transient ITSC.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (8) , 8899-8908
A Novel Approach Applied to Transient Short-Circuit Diagnosis in TIMs by Piezoelectric Sensors, PCA, and Wavelet Transform
Non-invasive fault diagnosis of three-phase induction motors (TIM) is widely used in industrial applications to ensure the integrity of processes. Among different types of TIM failures, transient inter-turn short circuits (ITSCs) are incipient stator winding faults characterized as short circuits between two or more turns of the coils, that can lead the winding to progressive deterioration, and consequently, the TIM to total failure. In this context, this article proposes a novel approach by using piezoelectric transducers, which performs the transient ITSC detection, phase identification, and magnitude classification by using the Acoustic Emission (AE) technique. To accomplish this analysis, a new statistical index based on the cross-correlation function was proposed to detect the ITSC and classify its magnitude. Besides, Wavelet Transform and Principal Component Analysis (PCA) stood out as promising tools to identify which phase was affected by the short circuits. A TIM was subjected to ITSCs and the experimental results showed that the proposed algorithm successfully performed the transient ITSC detection, phase identification, and evolution classification. Additionally, this work improve the capabilities of traditional AE systems, since no AE signal processing algorithm has ever been proposed for a comprehensive diagnosis of transient ITSC.
- 11 February 2022
- Published by Springer Nature
- p. 158-167
Real-Time Visual Respiration Tracking with Radar Sensors
- 11 February 2022
- Published by Springer Nature
- p. 158-167
Real-Time Visual Respiration Tracking with Radar Sensors